![Banner EZ-SCREEN Instruction Manual Download Page 46](http://html.mh-extra.com/html/banner/ez-screen/ez-screen_instruction-manual_471918046.webp)
+24V dc
0V dc
S1
S2
Y4
Y2
14
24
34
S3
S4
Y3
Y1
13
23
33
K2
K1
Machine
Control
Feedback (optional)
MPCE
2
MPCE
1
Receiver
8-pin male
Euro-style
face view
†
IM-T-9A***
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
*
*
Reset**
* Installation of transient (arc) suppressors
across the coils of MPCE1 and MPCE2 is
recommended (see Warning).
** Trip (auto reset) – Not connected
*** Other interfacing modules and solutions
available, see
Accessories or the
Banner Safety Catalog.
†
See
Accessories—Cordsets for further
QDE-8..D cable information.
Figure 22. Interface Module (2-channel EDM, with reset)—Generic Wiring
EZ-SCREEN
®
14/30 mm Safety Light Screen
46
www.bannerengineering.com - Tel: + 1 888 373 6767