Receiver
Emitter
Scan Code 2
Receiver
Emitter
Scan Code 1
a. Two systems in a horizontal plane
Receiver
Emitter
Scan Code 2
Receiver
Emitter
Scan Code 1
b. Two or three systems stacked (or alternate
receiver/emitter
positions)
Emitter
Receiver
Horizontal
Receiver
Horizontal
Emitter
Scan Code 1
Scan Code 2
c. Two systems at right angles
Receiver 1
Emitter 1
Scan Code 1
Receiver 2
Emitter 2
Scan Code 2
Receiver 3
Emitter 3
Scan Code 2
Opaque Shield
d.
Multiple
systems
Figure 9.
Installation
of
Multiple
Systems
WARNING:
Multiple
Pairs of Sensors
Do not connect
multiple
pairs of sensors to one Interface Module (for example, IM-T-9A/-11A) or otherwise
parallel OSSD outputs.
Connection
of
multiple
OSSD safety outputs to a single device may result in serious bodily
injury or death, and is prohibited.
WARNING:
Synchronization
In
situations
where
multiple
systems are mounted closely together, or where a secondary
emitter
is in view
(within ±5°), within range of an adjacent receiver; a receiver may synchronize to the signal from the wrong
emitter,
reducing the safety
function
of the light screen.
3.2
Mounting
System Components
3.2.1 Overview of
Emitter/Receiver
Mounting
Hardware
EZ-SCREEN
®
Type 2 Light Screen
www.bannerengineering.com - Tel: 763.544.3164
19