Mode
Threshold Offset (counts above taught signal value)
Super High-Speed
30
High-Speed
22
High-Power
9
Super High-Power
6
Figure 12. Dark Set Threshold Offset
1. Access the Set Mode.
Method
Action
Result
Push Button
Press and hold the Static button > 2 seconds
•
Display flashes “1St”
•
Arrow icon turns red
Remote Input6
Single-pulse the remote line
T
•
Display flashes “2nd”
•
Arrow icon turns red
2. Set the Output OFF condition.
Method
Action
Result
Push Button
a. Present the Output OFF condition
b. Five-click the Static button
Threshold Condition Accepted
•
Display flashes “Sn6l,” then "dr"
twice
•
Sensor returns to RUN mode with
new settings
•
Arrow icon turns green
Threshold Condition Unacceptable
•
Display flashes “FAIL” and
returns to “1St”
•
Arrow icon remains red
•
After 60 seconds, the sensor
returns to RUN mode (the Arrow
icon turns green) without
changing settings
Remote Input
a. Present the Output OFF condition
b. Five-pulse the remote line
T
T
T
T
T
T
T
T
T
Manual Adjust
Manual Adjust is used during Run mode and is accomplished using the push buttons only. Its behavior depends on whether a switching
threshold or a sensing window is used.
Switching Threshold:
• Fine-tunes sensing sensitivity
• Press “+” to increase; press “-” to decrease
Sensing Window:
• Adjusts sensing window size (tolerance) for the single-point target condition
• Press “+” to increase; press “-” to decrease
6 0.04 seconds
≤
T
≤
0.8 seconds
D10 Expert
™
- Analog and Discrete Outputs
P/N 65448 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
9