background image

3" Cast Iron Wet Seal  

301 Series Pump

Instruction Manual

301PIH13W, 301PBIW, 

301POIW

Read these instructions and the instructions covering the operation of the pump drive unit. Do not 

 

operate the gas engine (if so equipped) until you have put oil in the engine. Do not operate the wet 

seal pump until you have filled the wet seal reservoir 

¾

 full (the seal assembly should be 

 

submerged) with a 50% ethylene glycol (anti-freeze) and 50% water mixture.

Check the coolant mixture level in the wet seal reservoir after every 5 hours of use, fill reservoir as 

necessary. Check oil level in the gas engine (if so equipped) after every 5 hours of use, fill reservoir 

as necessary. Change coolant mixture in reservoir after every 100 hours of use or annually, which 

ever comes first.

Always fill the pump body with the liquid to be pumped before starting pump. It is not necessary to 

drain the pump body after use, unless there is a danger of freezing.

Make certain that all hose and pipe connections are air tight. An air leak in the suction line may 

 

prevent priming and will reduce the capacity of the pump. 

Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short 

and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy 

suction hose (made heavier when “primed” full of liquid) could result in a pump “down the hole”. 

There are important instructions regarding preparing the engine for long periods without use. (Read 

the engine instruction manual). Under these conditions, drain the pump and wet seal. Refill wet seal 

with fresh coolant mixture and reinstall fill and drain plugs. Leave all plugs (filter and drain) out of the 

pump. Always try to store the unit in a heated and dry building.

When pumping dirty water or other liquids containing solids, always use a pump strainer on the end 

of the suction line. There are no points on the pump which need lubrication. The wet seal assembly is 

cooled and lubricated by the ethylene glycol/water mixture.

Summary of Contents for 301PIH13W

Page 1: ...there is a danger of freezing Make certain that all hose and pipe connections are air tight An air leak in the suction line may prevent priming and will reduce the capacity of the pump Always place the pump as close to the liquid to be pumped as possible Keep the suction line short and with few bends Keep the pump and engine on a level foundation A poor foundation and a heavy suction hose made hea...

Page 2: ...3 Remove drive unit from the pump This is done by using a 9 16 wrench to remove the four 3 8 bolts 17704 that hold the drive unit to the wet seal reservoir adapter 18203A Once the bolts are removed separate the drive unit from the pump 4 Remove wet seal assembly from pump housing This is done by removing the six 3 8 nuts V20019 and 3 8 lock washers V20018 from the wet seal reservoir adapter 18203A...

Page 3: ...wet seal assembly It may be necessary to pry the cover plate away from the reservoir by using the pry tabs located on the cover plate 7 Remove the seal assembly 15035 from the wet seal assembly at this time 8 Inspect the wear plate 18004 and replace or repair as necessary 9 The inlet 18012 and outlet 18008 flanges and gaskets 18013 18009 can be inspected and replaced as necessary ...

Page 4: ...bolts be secured with Loctite 241 blue Securing the bolts in this fashion will not allow the bolts to vibrate loose during pump operation 3 Install the ceramic viton seal halves 15035 into the reservoir 18203A and cover plate 18202A Lubricate the O D of the viton seal with petroleum jelly and install the seal halves into the bores of the respective components by using a slight pressure with your t...

Page 5: ...petroleum jelly Slide onto shaft using your thumbs 7 Mate the reservoir adapter 18203A with the cover plate 18202A This is done by sliding the reservoir over the shaft and onto the cover plate Align the bolt patterns of the two parts also align the components such that the fill plug hole of the reservoir is facing up 8 Install six 3 8 lock washers V20018 and 3 8 nuts V20019 onto the six wet seal h...

Page 6: ...mp 18129 over the serrated tines of the wet seal shaft Lubricate the clamp bolts with anti seize thread lubricant and tighten to 40 ft lb minimum It may be necessary to further tighten the clamp depending upon drive unit size and pump load during operation 11 Fill the reservoir full with a 50 water 50 ethylene glycol anti freeze mix The fluid level should cover the top of the seal assembly Install...

Page 7: ... 6 18012 Flange Inlet 3 7 18002 1 NPT Plug 8 18004 Plate Wear 9 18009 Gasket Outlet 10 V20018 3 8 Lockwasher 11 V20019 3 8 Hex Nut 12 18021 Adapter Gasket 13 18129 Keyed Clamp 14 12910 Pump Decal 15 18200A Wet Seal Reservoir 16 17704 3 8 16 x 1 HHCS 17 18033 Handle 18 18034 Handle Nut 19 18500 Bearing Pedestal 20 18010SS 3 8 16 x 11 8 HHCS 6 ...

Page 8: ... 7367 765 362 0744 Crawfordsville IN 47933 800 458 0232 sales1 banjocorp com www banjocorp com 301PIH13W FLOW DATA 0 10 20 30 40 50 60 70 350 300 280 200 150 90 21 0 FLOW GPM 0 20 40 60 80 100 120 140 160 PRESSURE PSI HEAD FT ...

Reviews: