background image

This Service Manual must be returned with 
the defective parts/back-up suitcase !

Plasma Display Panel – 65 HD

Type D7

BeoVision 4 – 65, type 8959, 8990 - 8996

Service Manual 

Danish

English, G

erman, French, Italian, Spanish

 

and Dutch versions 

are available in the Retail System

ABO-CENTER 

v/HENRIKSENS 

ELEKTRONIK

Summary of Contents for BeoVision 4 - 65 type 8959

Page 1: ...back up suitcase Plasma Display Panel 65 HD Type D7 BeoVision 4 65 type 8959 8990 8996 Service Manual Danish English German French Italian Spanish and Dutch versions are available in the Retail Syste...

Page 2: ...lure and OSD menu 3 4 Replacement of modules 3 5 Test adjustment and con guration after repair 3 6 Final check after repair 3 8 PDP in service position 4 1 4 3 Remove contrast screen and plasma frame...

Page 3: ...Terminal J Slot Interface SYNC processor PC Power Supply Interface P SC Power Supply P SS Power Supply PF Line Filter SC Scan Out SD Scan Connection Lower SS Sustain Out SS2 Sustain Connection Upper S...

Page 4: ...bedst mulige sk rmbillede skal du s rge for at undg striber eller spor af reng ringsmidlet p sk rmen Burn in Der kan opst burn in p PDP en hvis der vises et still billede i mere end ca 30 minutter Adv...

Page 5: ...oVision 4 et BeoSystem og en DVD afspiller Standardinstillinger ved brug af fejltr Tryk p TV p Beo4 V lg en tv kanal med billede og lyd Fejl nding Handlinger f r demontering af PDP en Kontroll r PDP e...

Page 6: ...1 4 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 7: ...t billede PDP stand by lys gr nt PDP OSD menu OK PDP selvkontrol PCB J OK IC3003 3004 3005 3006 RGB forbindelse OK Mulige rsager RGB h ndtering Defekt PCB HX J D Fejlen kan ndes i n af PCB erne i PDP...

Page 8: ...Vpfc Vsus Vlow eller Vda fejl Udskift PCB P SC eller PCB P SS Vad fejl Udskift PCB SC Ve fejl Udskift PCB SS Fejlsymtom Farvefejl i billede Mulige rsager RGB fejl i PDP PCB D Aktiv r OSD p PDP Farver...

Page 9: ...enstre p PDP en Bliver lysdioden gr n Kontroll r kabel til PCB V1 Tryk p den tredje knap fra venstre p PDP en En menu vises p sk rmen Udskift PCB V1 IR kredsl b defekt Fejlsymptom Intet billede Fjernb...

Page 10: ...SS eller P 10 gange Terminaleffekt PCB PF PDP stand by lys blinker 2 gange Frakobl SC12 PDP start Stand by lysdiode gr n Tilslut SC12 Frakobl SS32 PDP start Stand by lysdiode gr n Bekr ft 1 Vsus SC11...

Page 11: ...e Bekr ft 5V p PCB D D25 ben 6 Udskift PCB P SS Ikke 5V fra PCB P Udskift PCB D PDP stand by lys blinker 5 gange Udskift PCB P SS OK Erstat PCB P SC med den gamle PCB P SS OK Udskift PCB PC A B O C E...

Page 12: ...kte Udskift PCB SS Udskift PCB Z PDP stand by lys blinker 7 gange Bekr ft at D415 er t ndt Bekr ft Vsus ved PCB SC SC2 ben 2 Bekr ft juster 1 Vpfc 2 Vsus 3 Vlow 4 Vda 5 Vad Udskift PCB P SC Kobl SU fr...

Page 13: ...15V forsyning OK Bekr ft 15V ved PCB SS P12 ben 4 Bekr ft Vsus Bekr ft juster 1 Vpfc 2 Vsus 3 Vlow 4 Vda Udskift PCB P SS Bekr ft Ve ved PCB SS Udskift PCB SS PDP stand by lys blinker 10 gange Kontrol...

Page 14: ...9V_STB5V DIG 12V SLOT 9V SLOT 5V SLOT 3 3V DR 15V C52 SC62 SC13 Vda 75V Vda 75V 78V SS12 SS10 11 Vsus 180V VDA 75V 15V 15V 12V STB_5V 15V 5V J14 J3 Z9 Z5 Z10 78V Line filter F900 F901 F903 F904 Main P...

Page 15: ...denne r kkef lge og skal altid gennemf res f r andre justeringer 1 PFC 2 Vsus 3 Vlow 4 Vda Modul Testpunkt V rdi Tolerance Juster ved Bem rkning P SS side PR401 PFC 395V 0 5V R443 SS side Jord W14 P...

Page 16: ...navn Tryk p stand by knappen p fjernbetjeningen uden navn for at t nde for PDP en Brug et spidst v rkt j eller en kuglepen til at trykke i hullet FF p fjernbetjeningen uden navn Resultatet af selvkont...

Page 17: ...Brug et spidst v rkt j eller en kuglepen til at trykke i hullet FD og derefter FE p fjernbetjeningen uden navn CAT Panel menu Service mode vises V lg IIC mode Flyt mark ren med pil op pil ned p fjernb...

Page 18: ...ng mellem fejl og modul Menuen OSD p PDP en Hvis PDP en er monteret i en aluminiumsramme skal du pege fjernbetjeningen uden navn mod hullet i det forreste nederste venstre hj rne af PDP en Se 6 1 Tryk...

Page 19: ...ftning af modul er p side 3 8 BEM RK Indvendige ledninger i PDP en V r forsigtig n r du kobler ledningerne fra stikkene Udskiftning af moduler F lg instruktionerne p side 4 1 4 3 PDP i serviceposition...

Page 20: ...etjening uden navn CAT Panel menu og CD mode 2 T nd for plasmapanelet Tryk p knappen m rket A Plasmalysdioden lyser gr nt 3 G ind i Service mode Tryk p FD og derefter p FE p fjernbetjeningen uden navn...

Page 21: ...ion 3 7 _ VOL R A LED B C OK R D CD MiCom Software version Memory data version Memory data change Address Data 2 11 S6 OK 1 20 24 8 63 Memory data version 0 0 0 0 1 2 3 VOL 1 1 2 2 3 7 A B O C E N T E...

Page 22: ...og justering af sp nding kan foretages med et DC voltmeter f eks et multimeter Jord forbindes til chassiset i PDP en medmindre andet er angivet Se side 3 1 vedr m le og justeringspunkter og v rdier Af...

Page 23: ...P in service position 1 2 2x Remove blinds Mount service stands incl brackets Mount straps Remove screws for wall bracket Mounting service stands A B O C E N T E R v H E N R I K S E N S E L E K T R O...

Page 24: ...ift of PDP and place on oor Keep your backs straight Positioning straps as shown and keep your backs straight lift the PDP Carry the PDP to a place suited for the repair A B O C E N T E R v H E N R I...

Page 25: ...iron frame Remove screws holding the aluminium frame Remove screws holding the back cover PDP in service position Remove aluminium frame and back cover 20x TX10 16x 14x A B O C E N T E R v H E N R I...

Page 26: ...ion Remove plugs Remove screws Pull out front at lift up SSP34 C4P04 Replace contrast screen and plasma frame 18x 13x Remove screws and gently lift out contrast screen A B O C E N T E R v H E N R I K...

Page 27: ...eplace PCB C1 Data Drive Upper left 4x Placement of PCB C1 Remove screws for FAN unplug FAN Remove plugs Open plugs as shown CAP01 CAP02 CAP03 CAP00 CAP04 CAP01 CAP03 CAP02 A B O C E N T E R v H E N R...

Page 28: ...4 6 Remove screws Replace PCB C1 Data Drive Upper left 8x Remove screws and genly pull out cables 6x A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 29: ...enter 4 1 PDP in service position 4x Placement of PCB C2 Remove screws for FAN unplug FAN Remove plugs Open plugs as shown CAP03 CAP02 CAP00 CAP01 CAP08 CAP07 CAP06 CAP04 CAP05 A B O C E N T E R v H E...

Page 30: ...4 8 Replace PCB C2 Data Drive Upper center Remove screws 6x Remove screws and genly pull out cables 6x A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 31: ...er right 4 1 PDP in service position 4x Placement of PCB C3 Remove screws for FAN unplug FAN Remove plugs Open plugs as shown CAP05 CAP03 CAP01 CAP02 CAP04 CAP01 CAP03 CAP02 A B O C E N T E R v H E N...

Page 32: ...4 10 Replace PCB C3 Data Drive Upper right Remove screws 8x Remove screws and genly pull out cables 6x A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 33: ...r right 4 1 PDP in service position 2x Placement of PCB C4 Remove screws for FAN unplug FAN Remove plugs Open plugs as shown CBP02 CBP01 CBP03 CBP04 CBP11 CBP08 CBP10 CBP09 H3 A B O C E N T E R v H E...

Page 34: ...4 12 Replace PCB C4 Data Drive Lower right Remove screws 8x Remove screws and genly pull out cables 6x A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 35: ...er 4 1 PDP in service position Placement of PCB C5 Remove plugs Open plugs as shown CBP05 CBP00 CBP02 CBP01 CBP07 CBP06 CBP05 6x Remove screws and genly pull out cables CBP04 CBP03 A B O C E N T E R v...

Page 36: ...4 14 Replace PCB C5 Data Drive Lower center Remove screws 5x A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 37: ...Lower left 4 1 PDP in service position 2x Placement of PCB C6 Remove screws for H3 remove H3 Remove plugs Open plugs as shown CBP02 CBP00 CBP03 CBP04 CBP01 CBP03 CBP02 H3 A B O C E N T E R v H E N R I...

Page 38: ...4 16 Replace PCB C6 Data Drive Lower left Remove screws 8x Remove screws and genly pull out cables 6x A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 39: ...n Placement of PCB D Remove cables from PCB D and PCB Z Remove srews and pull of PCB Z Remove plugs 5x ZP05 ZP06 ZP07 ZP08 ZP09 ZP10 ZP30 ZP31 ZP32 ZP33 ZP34 DP01 DP03 DP05 DP20 DP25 DP27 4x DP31 DP32...

Page 40: ...4 18 Replace PCB D Digital Signal Processor 7x Remove screws A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 41: ...9 4 1 PDP in service position Placement of PCB F FP2 FP9 6x Remove shield from PCB F Remove plugs Remove screws Replace PCB F Fuse Line Filter A B O C E N T E R v H E N R I K S E N S E L E K T R O N I...

Page 42: ...erminal 4x JP1 JP3 JP5 JP6 JP8 JP10 Remove plugs on PCB J 7x Remove screws on PCB J Remove screws on backside and remove PCB J 4 1 PDP in service position Placement of PCB HX A B O C E N T E R v H E N...

Page 43: ...4 21 Replace PCB HX PC Type Input Terminal 6x 4x 1x Remove screws Remove screws on the bottom Remove screw on PCB HX A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 44: ...C processor 4x JP1 JP3 JP5 JP6 JP8 JP10 Remove plugs on PCB J 7x Remove screws on PCB J Remove screws on backside and remove PCB J 4 1 PDP in service position Placement of PCB J A B O C E N T E R v H...

Page 45: ...B P SC Power Supply left Remove plugs PP02 PP07 PP09 PP10 PP11 PP12 PP23 PP25 PP27 PP700 8x Remove screws 4 1 PDP in service position Placement of PCB P SC A B O C E N T E R v H E N R I K S E N S E L...

Page 46: ...P SS Power Supply right Remove plugs PP02 PP05 PP07 PP09 PP10 PP11 PP12 PP25 PP27 PP700 Remove screws 4 1 PDP in service position Placement of PCB P SS 8x A B O C E N T E R v H E N R I K S E N S E L...

Page 47: ...4 25 Replace PCB PC Power Supply Interface 4x PCP700 PCP701 Remove plugs Remove screws 4 1 PDP in service position Placement of PCB PC A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 48: ...PCB PF Line Filter 4 1 PDP in service position Placement of PCB PF 2x PFP01 PFP02 PFP09 PFP10 11x Remove cover and plugs Remove GND wires Remove screws A B O C E N T E R v H E N R I K S E N S E L E K...

Page 49: ...Scan Out Remove PCB SU as shown SCP45 4x Remove PCB SD as shown 1 2 SU 1 2 4x SD SD SCP46 SU 4 1 PDP in service position Placement of PCB SC Remove FAN 4x 1 2 A B O C E N T E R v H E N R I K S E N S...

Page 50: ...4 28 Replace PCB SC Scan Out 11x Remove screws Remove plugs SCP02 SCP10 SCP11 SCP12 SCP13 SCP20 SCP23 SCP62 Very gentle pull out PCB SC A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 51: ...position Placement of PCB SD Remove PCB SD as shown 1 2 4x SD SD SCP46 SDP1 SDP2 SDP3 SDP4 Remove cables on backside of PCB SD Replace PCB SD Scan Connection Lower A B O C E N T E R v H E N R I K S E...

Page 52: ...position Placement of PCB SU Remove PCB SU as shown SUP45 4x 1 2 SU SU SUP1 SUP2 SUP3 SUP4 Remove cables on backside of PCB SU Replace PCB SU Scan Connection Upper A B O C E N T E R v H E N R I K S E...

Page 53: ...32 SSP34 SSP35 SSP42 4 1 PDP in service position Placement of PCB SS 4x Remove FAN tower Remove plugs Remove plugs on PCB SS2 and PCB SS3 SS2P23 SS2P24 SS3P27 SS3P28 1 2 Replace PCB SS Sustain Out A B...

Page 54: ...emove screws Remove screws Very gentle pull out PCB SS SSP54 SSP53 SSP55 SSP56 Open plugs as shown SSP54 SSP53 SSP55 SSP56 Replace PCB SS Sustain Out A B O C E N T E R v H E N R I K S E N S E L E K T...

Page 55: ...ion Placement of PCB SS2 Open plugs as shown and remove plugs SSP52 Remove plugs SSP23 SSP24 SSP52 Remove screws 4x SSP51 SSP51 Replace PCB SS2 Sustain Connection Upper A B O C E N T E R v H E N R I K...

Page 56: ...ion Placement of PCB SS3 Open plugs as shown and remove plugs SSP58 Remove plugs SSP23 SSP24 SSP58 Remove screws 4x SSP57 SSP57 Replace PCB SS3 Sustain Connection Lower A B O C E N T E R v H E N R I K...

Page 57: ...sition Placement of PCB Z Remove cables from PCB Z Remove srews and pull of PCB Z 5x ZP05 ZP06 ZP07 ZP08 ZP09 ZP10 ZP30 ZP31 ZP32 ZP33 ZP34 4x Replace PCB Z Audio out A B O C E N T E R v H E N R I K S...

Page 58: ...4 36 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 59: ...panel AC type 16 9 aspect ratio Brightness 300cd m2 Contrast ratio 3000 1 Viewing angle 160 Active picture area W x H 65 1434mm x 806mm 56 46in x 31 73in Pixel count 1 049 088 pixels 1366 x 768 x R G...

Page 60: ...5 2 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 61: ...8 Mains cable I 6100029 Mains cable CH 6100035 Mains cable UK 6100033 Mains cable AUS 6100052 Mains cable US 9007 3451286 Contrast screen 9008 3375448 Service stand incl pos no 9009 9009 3375449 Dista...

Page 62: ...SC 8003022 PC Board SC SD 8002333 PC Board SD SS 8003024 PC Board SS SS2 8002308 PC Board SS2 SS3 8002310 PC Board SS3 SU 8002335 PC Board SU S1 8002226 PC Board S1 V1 8002336 PC Board V1 Z 8002236 PC...

Page 63: ...302 3396299 Set of foam top and bottom 9303 3917105 Foam foil 9304 3392407 Outer box side 9305 3392200 Distance pipe 9306 3392419 Pallet 3375424 Tip and tell 9301 9302 9303 9304 9305 9304 9302 9301 93...

Page 64: ...Product cover 8053466 Special remote control 3375706 Micro bre cloth 3390436 Bag w wall bracket f IR sensor 3390519 Bag w rear plate f IR sensor 6270758 Wire f IR sensor 5m 8089110 IR sensor See Reta...

Page 65: ...A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Page 66: ...Bang Olufsen DK 7600 Struer Denmark Phone 45 96 84 11 22 Fax 45 97 85 39 11 3538024 04 05 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K...

Reviews: