Software • B&R Automation Device Interface (ADI) - Control Center
Chapter 4 Software
Panel PC 800 User's Manual V1.30
257
Deleting the data in flash memory can take several seconds depending on the memory block being used. The
progress indicator is not updated during this time.
Information:
The UPS is automatically restarted after a successful download. This can cause a brief failure in the
UPS communication.
11.4.5 Saving UPS battery settings
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.
3. Under "Battery settings", click on
Save
. This opens the "Save as" window.
4. Enter a filename or select an existing file and click on
Save
.
Information:
UPS settings can only be saved with UPS firmware version 1.10 and higher.
The transfer can be aborted by clicking on
Cancel
in the Download dialog box.
11.4.6 Configuring UPS system settings
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.
3. Under
UPS settings
, click on
Change
. This opens the following window:
Figure 139: ADI Control Center - UPS settings
Additional information regarding UPS system settings can be found in the Windows help documentation.
Information:
•
UPS settings can only be changed with UPS firmware version 1.10 and higher. If there are no
modified settings on the UPS, then the factory or default settings are used.
•
The UPS is automatically restarted after the UPS settings have been changed. This can cause
a brief disruption in communication with the UPS.
•
Administrator rights are required in order to change the energy options or display the UPS
status.