Software • BIOS options
Chapter 4 Software
Panel PC 800 User's Manual V1.30
209
1.4.13.1 Panel control
Advanced
Panel Control
Panel 0-14: connected
to Automation Panel
Link or Monitor/Panel
connector.
Brightness: [100%]
Panel 15: connected on
Panel PC Link.
Note: DVI and PPC Link
will show no valid
values. On PPC Link
only the brightness
option will work.
Select Screen
Select Item
+- Change Option
F1 General Help
F10 Save and Exit
ESC Exit
Select Panel Number [15]
Version: V0.00
Temperature: 00°C/32°F
Fan Speed: 00 RPM
Keys/Leds: 00/00
BIOS SETUP UTILITY
v02.59 (C)Copyright 1985-2005, American Megatrends, Inc.
Figure 115: 945GME Panel Control
BIOS setting
Function
Configuration options
Effect
Select panel number
Selects the panel number for which the values
should be displayed and/or changed
0...15
Selects panel 0-15
Version
Displays the firmware version of the SDLR con-
troller
None
-
Brightness
Sets the brightness of the selected panel
0%, 10%, 20%, 30%,
40%, 50%, 60%, 70%,
80%, 90%, 100%
Sets the brightness (in %) of the selected panel
Changes are effective immediately.
Temperature
Displays the selected panel's temperature in de-
grees Celsius and Fahrenheit
None
-
Fan speed
Displays the fan speed for the selected panel
None
-
Keys/LEDs
Displays the available keys and LEDs on the se-
lected panel
None
-
Table 163: 945GME Advanced - Panel control - Configuration options