Technical data
Automation PC 3100 User's manual V 1.00
Translation of the original documentation
109
2.3.6.4 5AC901.BUPS-00
2.3.6.4.1 General information
•
Battery unit for UPS IF option 5AC901.IUPS-00
•
Single-cell rechargeable battery
•
2 Hawker Cyclon 12 V 4.5 Ah rechargeable batteries connected in series
•
Rated voltage 24 V
•
Capacity 4.5 Ah
The battery unit is subject to wear and should be replaced regularly (after the specified service life at the latest).
Warning!
Battery unit 5AC901.BUPS-00 is only permitted to be operated with UPS IF option 5AC901.IUPS-00!
Information:
If the max. specified temperature limits of the battery unit are overshot or undershot, the temperature
alarm of the battery unit is set. Battery backing is no longer provided if the temperature alarm for the
battery unit is active. The battery is also no longer charged since this can result in damage to the
battery. This temperature alarm is defined with a hysteresis of 5°C, i.e. the temperature alarm is only
cleared again if the minimum temperature limit is again overshot by this hysteresis or the maximum
temperature limit is again undershot by this hysteresis. The temperature or temperature alarm of the
battery unit can be read/evaluated using the B&R ADI Library or the B&R implementation guide.
2.3.6.4.2 Order data
Model number
Short description
Figure
Uninterruptible power supplies
5AC901.BUPS-00
Battery unit 4.5 Ah - For UPS 5AC901.IUPS-00
Required accessories
Uninterruptible power supplies
5CAUPS.0005-01
UPS cable - 05 m - For 5AC901.IUPS-xx
5CAUPS.0010-01
UPS cable - 1 m - For 5AC901.IUPS-xx
5CAUPS.0013-01
UPS cable - 13 m - For 5AC901.IUPS-xx
5CAUPS.0030-01
UPS cable - 3 m - For 5AC901.IUPS-xx
Table 137: 5AC901.BUPS-00 - Order data
2.3.6.4.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
5AC901.BUPS-00
General information
Battery
Type
Hawker Cyclon 12 V 4.5 Ah, two rechargeable batteries connected in series
Service life
Up to 15 years at 20°C / 10 years at 25°C
1)
Design
Single cell
Temperature sensor
NTC resistance
Maintenance interval during storage
Charge 1 time every 6 months
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T3C
2)
GOST-R
Yes
Charge duration when battery low
Typ. 7 hours
Table 138: 5AC901.BUPS-00 - Technical data