background image

Technical data 

56

Panel PC 2100 user's manual V1.17

2.2.4.10 IF option slot (IF1, IFx)

Panel PC system units include 1 slot for an interface option.
The following table lists the interface options that can be used in this IF option slot.

IF option IF1, IFx slot

Model number

Short description

Interface option

5ACCIF01.FPCC-000

Interface card - 2x CAN interfaces - 1x X2X Link inter-

face - 1x POWERLINK interface - 512 kB nvSRAM - For

APC2100/PPC2100

5ACCIF01.FPCS-000

Interface card - 1x RS485 interface - 1x CAN interface -

1x POWERLINK interface - 32 kB FRAM - For APC2100/

PPC2100

5ACCIF01.FPLK-000

Interface  card  -  2x  POWERLINK  interfaces  -  512  kB

nvSRAM - For APC2100/PPC2100

5ACCIF01.FPLS-000

Interface card - 1x RS232 interface - 1x POWERLINK in-

terface - 32 kB FRAM - For APC2100/PPC2100

5ACCIF01.FPLS-001

Interface card - 1x RS232 interface - 1x POWERLINK in-

terface - 512 kB nvSRAM - For APC2100/PPC2100

5ACCIF01.FPSC-000

Interface card - 1x RS232 interface - 1x CAN interface -

1x POWERLINK interface - 32 kB FRAM - For APC2100/

PPC2100

5ACCIF01.FPSC-001

Interface card - 1x RS232 interface - 1x CAN interface -

1x X2X Link interface - 1x POWERLINK interface - 512

kB nvSRAM - For APC2100/PPC2100

5ACCIF01.FSS0-000

Interface card - 2x RS422/485 interfaces - For APC2100/

PPC2100

5ACCIF01.ICAN-000

Interface  card  -  1x  CAN  interface  -  For  APC2100/

PPC2100

IF1 IF option

IFx IF option

Table 46: IF1 IF option, IFx slot

Information:

Interface options can only be installed and replaced by B&R.

Summary of Contents for Panel PC 2100

Page 1: ...ial Automation GmbH is not liable for technical editorial errors or incomplete information in this manual In addition B R Industrial Automation GmbH shall not be liable for incidental or consequential...

Page 2: ...f jurisdiction in accordance with article 17 of the European Convention on Courts of Jurisdiction and Enforcement is A 4910 Ried im Innkreis Austria commercial register court Ried im Innkreis Austria...

Page 3: ...Chapter index Panel PC 2100 user s manual V1 17 3 1 General information 2 Technical data 3 Commissioning 4 Software 5 Standards and certifications 6 Accessories 7 Servicing and maintenance Appendix A...

Page 4: ...data 20 2 1 Introduction 20 2 1 1 About this user s manual 20 2 1 2 Description of individual modules 20 2 1 2 1 AP9x3 panels 20 2 1 2 2 AP1000 panels 20 2 1 2 3 System units 21 2 1 3 System component...

Page 5: ...20 101E 000 102 2 3 2 6 5AP1130 101E 000 104 2 3 2 7 5AP1120 1043 000 106 2 3 2 8 5AP1180 1043 000 109 2 3 2 9 5AP1181 1043 000 112 2 3 2 10 5AP1182 1043 000 115 2 3 2 11 5AP1120 1214 000 118 2 3 2 12...

Page 6: ...luating with the BurnInTest tool from PassMark 227 3 5 3 Evaluating temperatures in non Windows operating systems 229 3 5 4 Evaluating the measurement results 229 3 6 Touch screen calibration 230 3 6...

Page 7: ...75 4 4 1 General information 275 4 4 2 PPC2100 Order data 275 4 4 3 PPC2100 Overview 275 4 4 4 Features 275 4 4 5 Installation 275 4 4 6 Drivers 275 4 4 7 Activation 276 4 4 8 Issues and limitations 2...

Page 8: ...Order data 292 4 12 3 Overview 292 4 12 4 Features 292 4 12 5 Installation 292 4 12 6 Drivers 293 4 13 B R Linux 9 GNU Linux 294 4 13 1 General information 294 4 13 2 Order data 294 4 13 3 Overview 2...

Page 9: ...17 6 3 1 3 Technical data 317 6 3 1 4 Temperature Humidity diagram 319 6 3 2 5MMUSB 032G 02 320 6 3 2 1 General information 320 6 3 2 2 Order data 320 6 3 2 3 Technical data 320 6 3 2 4 Temperature Hu...

Page 10: ...335 A 5 1 1 Technical data 335 A 5 1 2 Temperature Humidity diagram 335 A 5 2 3M touch screen multi touch generation 2 336 A 5 2 1 General information 336 A 5 2 2 Technical data 336 A 5 2 3 Temperatur...

Page 11: ...h for USB 2 0 in section USB interfaces on page 52 Updated Maximum ambient temperature for typical operation on page 35 Updated section Ambient temperature during storage and transport on page 37 Upda...

Page 12: ...ted section Touch screen with 3M touch screen multi touch generation 2 and 3M touch screen multi touch generation 3 Updated CFast card 5CFAST 256G 10 see CFast cards on page 147 1 16 2018 06 20 Docume...

Page 13: ...using Do not touch the connector contacts on connected cables Do not touch the contact tips on circuit boards Electrical components without a housing The following points apply in addition to the poin...

Page 14: ...carried out in accordance with applicable guidelines e g wire cross sections fuses protective ground connections 1 2 6 Operation 1 2 6 1 Protection against touching electrical parts To operate progra...

Page 15: ...s against cyber threats it is necessary to implement and con tinuously maintain an integrated security concept that is state of the art B R products and solutions form only one part of such a concept...

Page 16: ...operty Notice Failure to observe these safety guidelines and notices can result in damage to property Table 3 Organization of safety notices General notices Contain useful information for users and in...

Page 17: ...640 x 480 pixels 4 3 Single touch analog resistive Control cabinet installation Landscape format For PPC2100 PPC2200 link modules Compatible with 5PP520 0573 00 92 5AP1120 0702 000 Automation Panel 7...

Page 18: ...9 Multi touch projected capacitive Control cabinet installation Landscape format For PPC900 PPC2100 PPC3100 PPC2200 For link modules 86 5AP933 240C 00 Automation Panel 24 0 Full HD TFT 1920 x 1080 pi...

Page 19: ...ense without Recovery DVD Only available with a new device 286 5SWWI7 1743 MUL Windows Embedded Standard 7 Premium SP1 32 bit Service Pack 1 English PPC2100 License without Recovery DVD Only available...

Page 20: ...ink module Automation Panel 9x3 or CPU board and system unit Panel PC 900 Panel PC 2100 Panel PC 2200 Panel PC 3100 The panels are installed using retaining clips Model numbers for single touch panels...

Page 21: ...d to meet individual requirements and operating conditions Automation Panel 9x3 Panel PC 900 Panel PC 2100 Panel PC 2200 and Panel PC 3100 systems are flexible so that an Automation Panel can be conve...

Page 22: ...7 VGA Single touch No Landscape 5AP1120 0702 000 7 0 WVGA Single touch No Landscape 5AP1120 101E 000 10 1 WXGA Single touch No Landscape 5AP1120 1043 000 10 4 VGA Single touch No Landscape 5AP1120 121...

Page 23: ...9 275 14 5 13 5 19 0 single touch 5AP923 1906 00 440 358 427 149 9 345 23 13 5 15 6 multi touch 5AP933 156B 00 414 258 5 401 105 5 9 245 5 20 13 5 18 5 multi touch 5AP933 185B 00 475 295 462 166 5 9 2...

Page 24: ...30 101E 000 279 191 266 38 9 178 18 13 5 10 4 single touch 5AP1120 1043 000 323 260 300 47 2 5 7 240 21 16 10 4 single touch with keys 5AP1180 1043 000 323 260 300 47 2 5 7 240 21 16 12 1 single touch...

Page 25: ...5AP1120 1214 000 362 284 309 52 5 5 7 234 20 3 17 5 264 339 15 0 single touch 5AP1120 1505 000 435 330 382 81 5 5 7 280 24 3 24 310 412 15 0 single touch with keys 5AP1180 1505 000 435 330 382 81 5 5...

Page 26: ...X Y Z min Z max Number of retaining clips 12 1 single touch 5AP923 1215 00 304 228 1 6 10 pcs 15 0 single touch 5AP923 1505 00 359 277 1 6 10 pcs 19 0 single touch 5AP923 1906 00 429 347 1 6 12 pcs 1...

Page 27: ...01E 000 268 180 1 6 8 10 4 single touch 5AP1120 1043 000 303 243 1 10 8 10 4 single touch with keys 5AP1180 1043 000 303 243 1 10 8 12 1 single touch 5AP1120 121E 000 313 210 5 1 6 10 12 1 multi touch...

Page 28: ...4 single touch with keys 5AP1182 1043 000 403 271 2 10 8 12 1 single touch 5AP1120 1214 000 342 267 2 10 8 15 0 single touch 5AP1120 1505 000 415 313 2 10 8 15 0 single touch with keys 5AP1180 1505 00...

Page 29: ...ntake and outlet are indicated in the following image The air intake is located on the bottom to accommo date the rising warm air S4 Rear view Side view S3 S2 S3 S1 S1 S2 Figure 8 Panel PC 2100 Spacin...

Page 30: ...tation Mounting orientation Ambient temperature limitation1 0 0 None A 1 to 90 counterclockwise 5 C B 1 to 90 clockwise 5 C C D 180 interfaces on top 5 C C 1 to 45 5 C C 46 to 90 10 C D 1 to 90 displa...

Page 31: ...uch with keys 5AP1180 1043 000 2800 10 4 single touch with keys 5AP1181 1043 000 3400 10 4 single touch with keys 5AP1182 1043 000 3500 12 1 single touch 5AP1120 1214 000 3200 12 1 single touch 5AP112...

Page 32: ...un der worst case conditions Experience has shown that higher ambient temperatures can be achieved in typical applications e g in Microsoft Windows Testing and evaluation in this regard must be per fo...

Page 33: ...5AP923 1906 00 D0 50 50 50 5AP923 1906 00 E0 5AP933 156B 00 C0 50 50 50 5AP933 156B 00 D0 5AP933 185B 00 50 50 50 5AP933 215C 00 C0 40 40 40 40 40 40 5AP933 215C 00 D0 50 50 50 5AP933 240C 00 C0 40 4...

Page 34: ...0 10 10 10 10 5AP933 185B 00 0 0 0 0 0 0 5AP933 215C 00 0 0 0 0 0 0 5AP933 240C 00 C0 0 0 0 0 0 0 AP9x3 panels 5AP933 240C 00 D0 10 10 10 10 10 10 5AP1120 0573 000 10 10 10 10 10 10 5AP1151 0573 000 0...

Page 35: ...60 60 55 55 55 What else can also be operated at the typ ambient temperature or is there a limitation Location of sensor s 5AP923 1215 00 5AP923 1505 00 5AP923 1906 00 D0 50 50 50 50 50 50 5AP923 190...

Page 36: ...ions and CFast cards are installed these components can change the temperature limits of the PPC2100 system 4 Limitations are possible due to the mounting orientation of the Panel PC 2100 For more inf...

Page 37: ...70 C 25 to 70 C 10 4 single touch with keys 5AP1181 1043 000 25 to 70 C 25 to 70 C 10 4 single touch with keys 5AP1182 1043 000 25 to 70 C 25 to 70 C 12 1 single touch 5AP1120 1214 000 25 to 80 C 25 t...

Page 38: ...iagnose2 B R PVI ADI line2 B R ADI SNMP Agent2 Automation Runtime Library2 In addition the CFast cards for PPC2100 systems available from B R are equipped with S M A R T or Self Moni toring Analysis a...

Page 39: ...D0 80 C 5AP1120 0573 000 80 C 5AP1151 0573 000 80 C 5AP1120 0702 000 85 C 5AP1130 0702 000 85 C 5AP1120 101E 000 80 C 5AP1130 101E 000 80 C 5AP1120 1043 000 90 C 5AP1180 1043 000 90 C 5AP1181 1043 00...

Page 40: ...10 to 90 10 to 90 12 1 single touch 5AP1120 121E 000 5 to 90 5 to 90 5 to 90 12 1 multi touch 5AP1130 121E 000 5 to 90 5 to 90 5 to 90 15 0 single touch 5AP1120 1505 000 8 to 90 8 to 90 8 to 90 15 0...

Page 41: ...2 4 Shock The following table provides an overview of the maximum shock values of the complete system Limitations are possible through the use of individual components Panel PC Operation1 Storage1 2 T...

Page 42: ...cement necessary or if the voltage supply is connected incorrectly reverse polarity protection fuse replacement not necessary The device must be returned to B R for repairs if the fuse is destroyed in...

Page 43: ...5 W 15 6 multi touch 5AP933 156B 00 D0 1 8 W 15 6 W 17 4 W 18 5 multi touch 5AP933 185B 00 6 1 W 10 8 W 16 9 W 21 5 multi touch 5AP933 215C 00 C0 7 4 W 18 3 W 25 7 W 21 5 multi touch 5AP933 215C 00 D0...

Page 44: ...ns Power calculation The following values are maximum values CFast cards Model number 5 V 3V3 12 V Power consumption Total CFast cards with SLC technology 5CFAST xxxx 00 0 7 W read 0 7 W write 0 3 W i...

Page 45: ...0 SATA0 PCIe 2 PCIe 3 ETH2 ETH1 USB interface 2 SMB Interface directed outwards Interface Optional or internal Gen7 iGFX optional SDRAM DDR3 SDRAM DDR3 USB Port 2_A USB interface 3 eDP2LVDS LVDS DDI1...

Page 46: ...K Green Green Red L2 LED L3 LED POWERLINK nvSRAM FPGA Green L1 LED Figure 14 IF option 2x POWERLINK nvSRAM 5ACCIF01 FPLK 000 Block diagram POWERLINK RS232 FRAM FPGA Mini PCIe connector Interface optio...

Page 47: ...tor 10 pin Yellow Green Green Red L1 LED L2 LED L3 LED Terminating resistor nvSRAM CAN X2X FPGA Isolator Isolator Figure 18 IF option POWERLINK RS232 CAN X2X nvSRAM 5ACCIF01 FPSC 001 Block diagram CAN...

Page 48: ...r supply 8 CFast CFast slot 2 Functional ground connection Grounding 9 Reset button Reset button 3 USB2 USB interfaces 10 ETH1 Ethernet 1 interface ETH1 4 USB1 USB interfaces 11 On Off Terminating res...

Page 49: ...3 pin screw clamp terminal block 0TB103 91 Male connector 24 V 5 08 3 pin cage clamp terminal block 3 pin male power supply connector 24 VDC power supply Table 37 24 VDC power supply connection Electr...

Page 50: ...V1 17 The ground connection must be used for example to fasten a copper strip to a central grounding point in the control cabinet or system where the device is installed The largest possible wire cro...

Page 51: ...e B R website www br automation com Information Only download necessary drivers from the B R website not from vendor websites 2 2 4 4 Ethernet 2 interface ETH2 This Ethernet controller is connected to...

Page 52: ...480 Mbit s SuperSpeed 5 Gbit s 2 Current carrying capacity3 USB1 Max 1 A Cable length USB 2 0 USB 3 0 Max 5 m without hub Max 3 m without hub 1x USB type A female USB2 USB1 Table 40 USB1 interface 1 T...

Page 53: ...y 15 4 3 format only and 19 display sizes are equipped with a USB 2 0 interface on the front For more information see section USB interface on page 62 USB hub interfaces 4 port USB hub 5ACCUSB4 0000 0...

Page 54: ...is only permitted to be connected or disconnected when the power is switched off 2 2 4 7 Power button The power button provides a wide range of ATX power supply functions Power button The Power button...

Page 55: ...inking Faulty or incomplete BIOS MTCX or I O FPGA update stand by mode S5 soft off mode or S4 hibernation suspend to disk mode CFast Yellow On Indicates CFast access On Indicates an active SDL connect...

Page 56: ...rfaces 512 kB nvSRAM For APC2100 PPC2100 5ACCIF01 FPLS 000 Interface card 1x RS232 interface 1x POWERLINK in terface 32 kB FRAM For APC2100 PPC2100 5ACCIF01 FPLS 001 Interface card 1x RS232 interface...

Page 57: ...Yes 12 1 single touch 5AP1120 1214 000 SVGA Single touch No No Yes 12 1 single touch 5AP1120 121E 000 WXGA Single touch No No No 12 1 multi touch 5AP1130 121E 000 WXGA Multi touch No No No 15 0 single...

Page 58: ...f 128 bits each The positions of keys and LEDs in the matrix are represented as hardware numbers The hardware numbers can be read directly on the target system using the B R Key Editor or B R Control...

Page 59: ...Technical data Panel PC 2100 user s manual V1 17 59 5AP1180 1043 000 Figure 26 5AP1180 1043 000 Key and LED configuration 5AP1181 1043 000 Figure 27 5AP1181 1043 000 Key and LED configuration...

Page 60: ...Technical data 60 Panel PC 2100 user s manual V1 17 5AP1182 1043 000 Figure 28 5AP1182 1043 000 Key and LED configuration 5AP1180 1505 000 Figure 29 5AP1180 1505 000 Key and LED configuration...

Page 61: ...Technical data Panel PC 2100 user s manual V1 17 61 5AP1181 1505 000 Figure 30 5AP1181 1505 000 Key and LED configuration...

Page 62: ...face is designed according to general PC specifications extreme care should be taken with regard to EMC wiring etc Front USB The front USB interface is available to the user for service purposes Unive...

Page 63: ...lerance for PP100 200 PP300 400 PP500 AP900 PPC700 and PPC800 systems is 0 5 mm The cutout tolerance for the AP1000 is 0 mm 0 5 mm Compatibility between device types is represented on each line by mat...

Page 64: ...13 415 x 312 415 x 312 Outer dimensions 435 x 430 435 x 430 435 x 430 435 x 430 435 x 430 15 Vertical1 Installation dimensions 415 x 412 415 x 412 415 x 413 415 x 412 415 x 412 Outer dimensions 477 x...

Page 65: ...200 300 400 8 5 AP900 PPC700 PP500 Cutout for AP900 PPC700 PP500 device 4 5 423 x 288 10 10 8 5 Installation dimensions e g depending on the device type Outer dimensions PP500 403 x 271 402 x 266 5 F...

Page 66: ...8 199 x 232 PP500 5 2 AP1000 6 5 PP500 AP1000 Figure 34 Mounting compatibility 5 7 device Vertical1 5 7 Automation Panel 1000 and Power Panel 500 devices are not 100 mounting compatible with Power Pan...

Page 67: ...3 PP100 200 300 400 8 5 AP900 PPC700 PP500 AP1000 Cutout for AP900 PPC700 device 4 5 423 x 288 10 10 8 5 402 x 271 402 x 266 5 403 x 271 PP500 Cutout for PP500 AP1000 device AP1000 Figure 36 Mounting...

Page 68: ...C 700 and Power Panel 500 devices are not 100 mounting compatible with Power Panel 100 200 300 400 devices in Vertical1 format Automation Panel 1000 Au tomation Panel 900 Panel PC 700 and Power Panel...

Page 69: ...ut for AP900 PPC700 PP500 AP1000 device 1 5 342 x 267 345 x 267 PP500 AP1000 Figure 38 Mounting compatibility 12 1 device Horizontal1 12 1 Automation Panel 1000 Automation Panel 900 Panel PC 700 and P...

Page 70: ...mounting make sure that the PP100 200 PP300 400 AP900 PPC700 and PPC800 devices are placed and mounted as close to the center of the cutout as possible Failure to do so can prevent the retaining clips...

Page 71: ...Automation Panel 900 devices are 100 mounting compatible with Panel PC 700 devices in the Horizontal1 format 2 2 6 2 7 19 devices The cutout tolerance for PP100 200 PP300 400 PP500 AP900 PPC700 and P...

Page 72: ...utout tolerance for PP100 200 PP300 400 PP500 AP900 PPC700 and PPC800 systems is 0 5 mm The cutout tolerance for the AP1000 is 0 mm 0 5 mm 583 x 464 8 5 8 5 8 5 8 5 Outer contour of device Cutout for...

Page 73: ...s individual component and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete...

Page 74: ...239 mm Weight 2200 g Table 51 5AP923 1215 00 Technical data 1 Yes although applies only if all components installed in the complete system have this certification and the complete system bears the co...

Page 75: ...hich this individual component is used for example the data specified for that complete system applies Model number 5AP923 1505 00 General information B R ID code 0xE169 Certifications CE Yes UL cULus...

Page 76: ...omplete system have this certification and the complete system bears the corresponding mark 2 Yes although applies only if all components installed in the complete system have this certification and a...

Page 77: ...stem applies Model number 5AP923 1906 00 Revision D0 E0 General information B R ID code 0xE1B1 Certifications CE Yes UL cULus E115267 Industrial control equipment HazLoc cULus HazLoc E180196 Industria...

Page 78: ...and the complete system bears the corresponding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 Touch screen drivers...

Page 79: ...30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Storage Transport Relative humidity RH non condensing Operation Storage Transport...

Page 80: ...that complete system applies Model number 5AP933 156B 00 Revision C0 D0 General information B R ID code 0xE16A Certifications CE Yes UL cULus E115267 Industrial control equipment GOST R Yes Display T...

Page 81: ...ducing the brightness by 50 can increase the half brightness time by approximately 50 2 3 1 4 4 Dimensions 414 258 5 Figure 51 5AP933 156B 00 Dimensions 2 3 1 4 5 Temperature Humidity diagram 0 0 10 2...

Page 82: ...0 0 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Relative humidity RH non condensing Storage Transport Operation Figure...

Page 83: ...r example the data specified for that complete system applies Model number 5AP933 185B 00 Revision C0 D0 General information B R ID code 0xE16B Certifications CE Yes UL cULus E115267 Industrial contro...

Page 84: ...ducing the brightness by 50 can increase the half brightness time by approximately 50 2 3 1 5 4 Dimensions295 475 Figure 54 5AP933 185B 00 Dimensions 2 3 1 5 5 Temperature Humidity diagram 0 0 10 20 3...

Page 85: ...0 0 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Storage Transport Relative humidity RH non condensing Operation Figure...

Page 86: ...example the data specified for that complete system applies Model number 5AP933 215C 00 Revision C0 D0 General information B R ID code 0xE16C Certifications CE Yes UL cULus E115267 Industrial control...

Page 87: ...00 Technical data 1 At an ambient temperature of 25 C Reducing the brightness by 50 can increase the half brightness time by approximately 50 2 3 1 6 4 Dimensions 541 5 333 Figure 57 5AP933 215C 00 D...

Page 88: ...Technical data 88 Panel PC 2100 user s manual V1 17 Storage Transport Temperature C Relative humidity RH non condensing Operation Figure 59 5AP933 215C 00 D0 Temperature Humidity diagrams...

Page 89: ...d for example the data specified for that complete system applies Model number 5AP933 240C 00 Revision C0 D0 General information B R ID code 0xE1B4 Certifications CE Yes UL cULus E115267 Industrial co...

Page 90: ...have this certification and are listed on the associated DNV GL certificate for the product family 2 At an ambient temperature of 25 C Reducing the brightness by 50 can increase the half brightness t...

Page 91: ...0 0 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Relative humidity RH non condensing Operation Storage Transport Figure...

Page 92: ...stem in which this individual component is used for example the data specified for that complete system applies Product ID 5AP1120 0573 000 Revision D0 E0 General information B R ID code 0xE7AA Certif...

Page 93: ...s installed in the complete system have this certification and the complete system bears the corresponding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can increase the half...

Page 94: ...ta 94 Panel PC 2100 user s manual V1 17 2 3 2 1 6 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 64 5AP1120 0573 000 Temperature humi...

Page 95: ...lete system in which this individual component is used for example the data specified for that complete system applies Product ID 5AP1151 0573 000 Revision D0 E0 General information B R ID code 0xE7AB...

Page 96: ...ble 67 5AP1151 0573 000 5AP1151 0573 000 Technical data 1 Yes although applies only if all components installed in the complete system have this certification and the complete system bears the corresp...

Page 97: ...ta Panel PC 2100 user s manual V1 17 97 2 3 2 2 6 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 66 5AP1151 0573 000 Temperature humi...

Page 98: ...ent is used for example the data specified for that complete system applies Model number 5AP1120 0702 000 General information B R ID code 0xE7AC Certifications CE Yes UL cULus E115267 Industrial contr...

Page 99: ...ertification and the complete system itself carries the corresponding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brig...

Page 100: ...sed for example the data specified for that complete system applies Model number 5AP1130 0702 000 General information B R ID code 0xEB61 Certifications CE Yes UL cULus E115267 Industrial control equip...

Page 101: ...nding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brightness time 3 The specifications for the touch screen driver mus...

Page 102: ...sed for example the data specified for that complete system applies Model number 5AP1120 101E 000 General information B R ID code 0xE93D Certifications CE Yes UL cULus E115267 Industrial control equip...

Page 103: ...tion and the complete system itself carries the corresponding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brightness t...

Page 104: ...example the data specified for that complete system applies Model number 5AP1130 101E 000 General information B R ID code 0xEB62 Certifications CE Yes UL cULus E115267 Industrial control equipment Ha...

Page 105: ...nding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brightness time 3 The specifications for the touch screen driver mus...

Page 106: ...d may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete system applies Model numb...

Page 107: ...hough applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2 At an ambient temperature of 25 C Reducing the brig...

Page 108: ...a 108 Panel PC 2100 user s manual V1 17 2 3 2 7 6 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 76 5AP1120 1043 000 Temperature Humi...

Page 109: ...s individual component and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete...

Page 110: ...Height 260 mm Weight 2800 g Table 79 5AP1180 1043 000 Technical data 1 Yes although applies only if all components installed in the complete system have this certification and the complete system bea...

Page 111: ...a Panel PC 2100 user s manual V1 17 111 2 3 2 8 6 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 78 5AP1180 1043 000 Temperature Humi...

Page 112: ...following specifications properties and limit values apply only to this individual component and may deviate from those that apply to the complete system For the complete system in which this individ...

Page 113: ...er Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm built in gasket Dimensions Width 323 mm Height 358 mm Weight 3400 g Table 81 5AP1181 1043 000 Technical data 1 Yes alt...

Page 114: ...for PPC2100 system unit 5PPC2100 BYxx 000 Firmware V1 18 or later for PPC900 system unit 5PC901 TS77 xx 2 3 2 9 6 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operati...

Page 115: ...mit values apply only to this individual component and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data...

Page 116: ...dth 423 mm Height 288 mm Weight 3500 g Table 83 5AP1182 1043 000 Technical data 1 Yes although applies only if all components installed in the complete system have this certification and the complete...

Page 117: ...a Panel PC 2100 user s manual V1 17 117 2 3 2 10 6 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 82 5AP1182 1043 000 Temperature Hum...

Page 118: ...and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete system applies Model nu...

Page 119: ...gray border around display RAL 7024 Gasket 3 mm built in seal Dimensions Width 362 mm Height 284 mm Weight 3200 g Table 85 5AP1120 1214 000 Technical data 1 Yes although applies only if all component...

Page 120: ...a 120 Panel PC 2100 user s manual V1 17 2 3 2 11 5 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 84 5AP1120 1214 000 Temperature Hum...

Page 121: ...s used for example the data specified for that complete system applies Model number 5AP1120 121E 000 General information B R ID code 0xE8E4 Certifications CE Yes UL cULus E115267 Industrial control eq...

Page 122: ...ion and the complete system itself carries the corresponding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brightness ti...

Page 123: ...or example the data specified for that complete system applies Model number 5AP1130 121E 000 General information B R ID code 0xEB63 Certifications CE Yes UL cULus E115267 Industrial control equipment...

Page 124: ...ding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brightness time 3 The specifications for the touch screen driver must...

Page 125: ...is individual component and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete...

Page 126: ...gray border around display RAL 7024 Gasket 3 mm built in seal Dimensions Width 435 mm Height 330 mm Weight 5000 g Table 91 5AP1120 1505 000 Technical data 1 Yes although applies only if all component...

Page 127: ...a Panel PC 2100 user s manual V1 17 127 2 3 2 14 5 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 90 5AP1120 1505 000 Temperature Hum...

Page 128: ...vidual component and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete system...

Page 129: ...ized aluminum Keypad overlay Material Polyester Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm built in gasket Dimensions Width 435 mm Height 330 mm Weight 4900 g Table...

Page 130: ...a 130 Panel PC 2100 user s manual V1 17 2 3 2 15 5 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 92 5AP1180 1505 000 Temperature Hum...

Page 131: ...94 5AP1181 1505 000 Order data 2 3 2 16 3 Technical data Information The following specifications properties and limit values apply only to this individual component and may deviate from those that ap...

Page 132: ...h installed link module or installed system unit Protection per UL 50 Front Type 4X indoor use only Mechanical properties Front 4 Frame Naturally anodized aluminum Keypad overlay Material Polyester Li...

Page 133: ...th the following firmware versions Firmware V03 15 or later for SDL DVI receiver 5DLSDL 1001 00 Firmware V04 11 or later for SDL3 receiver 5DLSD3 1001 00 Firmware V06 12 or later for SDL4 receiver 5DL...

Page 134: ...anel PC 2100 user s manual V1 17 2 3 2 16 7 Cutout installation 0 Cutout dimensions 415 0 5 mm x 413 0 5 mm Cutout Outer contour Automation Panel 0 10 435 425 430 8 5 421 5 Figure 95 5AP1181 1505 000...

Page 135: ...ponent is used for example the data specified for that complete system applies Model number 5AP1120 156B 000 General information B R ID code 0xE8E5 Certifications CE Yes UL cULus E115267 Industrial co...

Page 136: ...ion and the complete system itself carries the corresponding mark 2 At an ambient temperature of 25 C Reducing the brightness by 50 can result in an approximately 50 increase in the half brightness ti...

Page 137: ...tem For the complete system in which this individual component is used for example the data specified for that complete system applies Model number 5AP1130 156C 000 General information B R ID code 0xE...

Page 138: ...gh applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for the product family 3 At an ambient temperature of 25...

Page 139: ...for example the data specified for that complete system applies Model number 5AP1130 185C 000 General information B R ID code 0xEC5E Certifications CE Yes UL cULus E115267 Industrial control equipmen...

Page 140: ...ing the brightness by 50 can increase the half brightness time by approximately 50 3 The values for the touch screen driver must be taken into account See chapter 4 Software section 2 Multi touch driv...

Page 141: ...al component and may deviate from those that apply to the complete system For the complete system in which this individual component is used for example the data specified for that complete system app...

Page 142: ...uilt in gasket Dimensions Width 527 mm Height 421 mm Weight 7300 g Table 103 5AP1120 1906 000 Technical data 1 Yes although applies only if all components installed in the complete system have this ce...

Page 143: ...Panel PC 2100 user s manual V1 17 143 2 3 2 20 5 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 103 5AP1120 1906 000 Temperature Hum...

Page 144: ...8G 10 CFast card 128 GB MLC 5CFAST 256G 10 CFast card 256 GB MLC Optional accessories Interface options 5ACCIF01 FPCC 000 Interface card 2x CAN interfaces 1x X2X Link interface 1x POWERLINK interface...

Page 145: ...ure Yes Intel Hyper Threading Technology No Intel vPro Technology No Intel Virtualization Technology VT x Yes Intel Virtualization Technology for Directed I O VT d No Enhanced Intel SpeedStep Tech nol...

Page 146: ...Y11 000 5PPC2100 BY22 000 5PPC2100 BY34 000 5PPC2100 BY44 000 5PPC2100 BY48 000 Technical data 1 Yes although applies only if all components installed within the complete system have this certificatio...

Page 147: ...also widely used in this market 2 3 4 2 2 Wear leveling Wear leveling refers to an algorithm that can be used to maximize the service life of a CFast card Different algo rithms are possible Dynamic we...

Page 148: ...e the system with the respective data storage device over a defined period of time e g 1 week Determine the number of completed erase cycles with Average erase count Calculate the expected service lif...

Page 149: ...ons when using older cloning tools This is generally not the case when using current cloning tools Information The following specifications properties and limit values apply only to this accessory and...

Page 150: ...PPC900 Operating systems Windows 10 IoT Enterprise LTSB 64 bit No No No No Yes Windows Embedded 8 1 Industry Pro 32 bit No No No Yes Yes Windows Embedded 8 1 Industry Pro 64 bit No No No No Yes Windo...

Page 151: ...nly if all components installed in the complete system have this certification and the complete system bears the corresponding mark 3 Yes although applies only if all components installed in the compl...

Page 152: ...v D0 Table 109 5CFAST 032G 10 5CFAST 064G 10 5CFAST 128G 10 Order data 2 3 4 4 3 Technical data Caution A sudden power failure may result in data loss In very rare cases the mass storage device may al...

Page 153: ...ort Hardware APC3100 APC2200 APC2100 APC910 PPC3100 PPC2200 PPC2100 PPC900 Operating systems Windows 10 IoT Enterprise LTSB 64 bit Yes Windows Embedded 8 1 Industry Pro 32 bit Yes Windows Embedded 8 1...

Page 154: ...The following specifications properties and limit values apply only to this accessory and may deviate from those that apply to the complete system For the complete system in which this accessory is in...

Page 155: ...tion Operation 7 to 2000 Hz 20 g peak Storage 7 to 2000 Hz 20 g peak Transport 7 to 2000 Hz 20 g peak Shock Operation 1500 g peak 0 5 ms Storage 1500 g peak 0 5 ms Transport 1500 g peak 0 5 ms Mechani...

Page 156: ...sing Operation Storage Transport Figure 107 5CFAST 032G 10 Rev G0 5CFAST 064G 10 Rev E0 5CFAST 128G 10 Rev E0 5CFAST 256G 10 Temperature Humidity diagram Temperature C Relative humidity RH non condens...

Page 157: ...e CFast card If write protection is enabled data can only be read Information If an operating system is installed on the CFast card write protection must be disabled Enabled Disabled Figure 109 CFast...

Page 158: ...000 Interface card 2x CAN interfaces 1x X2X Link interface 1x POWERLINK interface 512 kB nvSRAM For APC2100 PPC2100 APC2200 PPC2200 Only available with a new de vice Optional accessories Terminal blo...

Page 159: ...ough applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2 Yes although applies only if all components installe...

Page 160: ...on Studio Automation Runtime It is not a PC interface and therefore not shown in BIOS CAN driver settings The baud rate can be set either with predefined values or the bit timing register For addition...

Page 161: ...The terminating resistor cannot be switched on off for the CAN bus 2 interface Terminating resistor On The terminating resistor is switched on Off The terminating resistor is switched off Terminating...

Page 162: ...Extension Transfer rate 1000 m Typ 50 kbit s 200 m Typ 250 kbit s 100 m Typ 500 kbit s 20 m1 Typ 1 Mbit s Table 122 CAN2 Bus length and transfer rate 1 The specified cable length is only valid with th...

Page 163: ...be put on pin 2 of the female connector A functional ground connection and screw which can also be used for the cable shields is located on the interface plate of the system unit 2 3 5 1 3 6 LED statu...

Page 164: ...ored for POWERLINK frames If a corresponding frame is not received within the configured time frame timeout then the module immediately enters mode BASIC_ETHERNET flickering If POWERLINK communication...

Page 165: ...active and cyclic data is evaluated Blinking approx 2 5 Hz STOPPED State The interface is in state STOPPED Managing node MN This state is not possible for the MN Controlled node CN No output data is o...

Page 166: ...2 3 Technical data Information The following specifications properties and limit values apply only to this accessory and may deviate from those that apply to the complete system For the complete syste...

Page 167: ...ion Hardware IF LS 2 3 5 2 3 1 POWERLINK interface Pinout The POWERLINK interface on the system unit is referred to as IF1 POWERLINK IF11 2 Wiring S STP Cat 5e Cable length Max 100 m min Cat 5e Status...

Page 168: ...following properties or deviate from them as little as possible to achieve an optimal transfer rate RS485 cables Property Signal lines Cable cross section Wire insulation Conductor resistance Strandi...

Page 169: ...in the timing register The material used for the cable should have all of the following properties or deviate from them as little as possible to achieve an optimal transfer rate CAN cable Property Sig...

Page 170: ...rror L3 Green Red Off POWERLINK Status Error LED See LED Status Error L1 L2 L3 Table 141 5ACCIF01 FPCS 000 LED status indicators LED Status Error LED Status Error is a green and red dual LED The LED s...

Page 171: ...yet taking place Controlled node CN The module can be configured by the MN in this state The CN waits until it receives an SoC frame and then switches to state PRE_OPERATIONAL_2 double flash A solid r...

Page 172: ...cription Error code indicated by red Status LED RAM error The interface is defective and must be replaced Pause Pause Hardware error The interface or a system component is defective and must be replac...

Page 173: ...dancy and simultaneous poll response chaining operation is not possible with this IF op tion 2 3 5 3 2 Order data Model number Short description Figure Interface options 5ACCIF01 FPLK 000 Interface ca...

Page 174: ...rface on the system unit is referred to as IF1 POWERLINK 1 IF11 Wiring S STP Cat 5e Cable length Max 100 m min Cat 5e Status LED On Off Green See Status Error LED Link LED On Off Yellow Link POWERLINK...

Page 175: ...ror L1 L2 L3 Table 150 5ACCIF01 FPLK 000 LED status indicators LED Status Error LED Status Error is a green and red dual LED The LED states have a different meaning depending on the operating mode Eth...

Page 176: ...yet taking place Controlled node CN The module can be configured by the MN in this state The CN waits until it receives an SoC frame and then switches to state PRE_OPERATIONAL_2 double flash A solid r...

Page 177: ...cription Error code indicated by red Status LED RAM error The interface is defective and must be replaced Pause Pause Hardware error The interface or a system component is defective and must be replac...

Page 178: ...nd may deviate from those that apply to the complete system For the complete system in which this accessory is installed for example the data specified for that complete system applies Model number 5A...

Page 179: ...us Error LED Link LED On Off Yellow Link POWERLINK net work connection available Activity blinks to indi cate active data transfer RJ45 female 1 LED Status LED Link Table 157 5ACCIF01 FPLS 000 POWERLI...

Page 180: ...s Error LED Status Error is a green and red dual LED The LED states have a different meaning depending on the operating mode Ethernet mode In this mode the interface is operated as an Ethernet interfa...

Page 181: ...yet taking place Controlled node CN The module can be configured by the MN in this state The CN waits until it receives an SoC frame and then switches to state PRE_OPERATIONAL_2 double flash A solid r...

Page 182: ...nterface or a system component is defective and must be replaced Pause Pause Table 163 System stop error codes Legend 150 ms 600 ms Pause 2 second pause 2 3 5 4 3 4 Shielding For the interfaces on the...

Page 183: ...deviate from those that apply to the complete system For the complete system in which this accessory is installed for example the data specified for that complete system applies Model number 5ACCIF01...

Page 184: ...tatus LED Link Table 166 5ACCIF01 FPLS 001 POWERLINK interface 1 The interfaces etc available on the device or module have been numbered as such for the purpose of clear differentiation This numbering...

Page 185: ...s Error LED Status Error is a green and red dual LED The LED states have a different meaning depending on the operating mode Ethernet mode In this mode the interface is operated as an Ethernet interfa...

Page 186: ...yet taking place Controlled node CN The module can be configured by the MN in this state The CN waits until it receives an SoC frame and then switches to state PRE_OPERATIONAL_2 double flash A solid r...

Page 187: ...nterface or a system component is defective and must be replaced Pause Pause Table 172 System stop error codes Legend 150 ms 600 ms Pause 2 second pause 2 3 5 5 3 4 Shielding For the interfaces on the...

Page 188: ...PSC 000 Order data 2 3 5 6 3 Technical data Information The following specifications properties and limit values apply only to this accessory and may deviate from those that apply to the complete syst...

Page 189: ...omplete system have this certification and the complete system bears the corresponding mark 2 Yes although applies only if all components installed in the complete system have this certification and a...

Page 190: ...t s Bus length Max 1000 m Pin Assignment 1 2 Shield 3 4 5 CAN H 6 CAN L 7 CAN GND 8 9 10 10 pin male 1 3 5 7 2 4 6 8 10 9 Table 177 5ACCIF01 FPSC 000 CAN bus interface 1 The interfaces etc available o...

Page 191: ...grated in the interface option above the ETH1 interface A switch is used to enable or disable the terminating resistor for the CAN bus interface The L1 LED status indicator indicates whether the termi...

Page 192: ...ode PRE_OPERATIONAL_1 single flash If POWERLINK communica tion is detected before the time expires however then the MN is not started Controlled node CN The bus is monitored for POWERLINK frames If a...

Page 193: ...active and cyclic data is evaluated Blinking approx 2 5 Hz STOPPED State The interface is in state STOPPED Managing node MN This state is not possible for the MN Controlled node CN No output data is o...

Page 194: ...mp terminal block Protected against vibration by the screw flange Table 187 5ACCIF01 FPSC 001 Order data 2 3 5 7 3 Technical data Information The following specifications properties and limit values a...

Page 195: ...tics Weight 25 g Table 188 5ACCIF01 FPSC 001 Technical data 1 Yes although applies only if all components installed in the complete system have this certification and the complete system bears the cor...

Page 196: ...Bus length Max 1000 m Pin Assignment 1 2 Shield 3 4 5 CAN H 6 CAN L 7 CAN GND 8 9 10 10 pin male 1 3 5 7 2 4 6 8 10 9 Table 191 5ACCIF01 FPSC 001 CAN bus interface 1 The interfaces etc available on th...

Page 197: ...s Terminating resistor A terminating resistor is integrated in the interface option above the ETH1 interface A switch is used to enable or disable the terminating resistor for the CAN bus interface Th...

Page 198: ...Data transfer in progress On POWERLINK Status Error LED See LED Status Error L3 Green Red Off POWERLINK Status Error LED See LED Status Error L1 L2 L3 Table 197 5ACCIF01 FPSC 000 LED status indicator...

Page 199: ...yet taking place Controlled node CN The module can be configured by the MN in this state The CN waits until it receives an SoC frame and then switches to state PRE_OPERATIONAL_2 double flash A solid r...

Page 200: ...cription Error code indicated by red Status LED RAM error The interface is defective and must be replaced Pause Pause Hardware error The interface or a system component is defective and must be replac...

Page 201: ...data specified for that complete system applies Model number 5ACCIF01 FSS0 000 General information LED status indicators L2 L3 B R ID code 0xED7B Certifications CE Yes UL cULus E115267 Industrial cont...

Page 202: ...ed by the respective operating system however 2 This interface if available is enabled automatically in BIOS as COMA with default I O address 3F8h and IRQ 4 3 This interface is referred to as IF7 in A...

Page 203: ...ing used by the respective operating system however 2 This interface if available is enabled automatically in BIOS as COMD with default I O address 2F8h and IRQ 10 3 This interface is referred to as I...

Page 204: ...wire PE 59 km Outer jacket Material Properties Complete shielding PUR compound Halogen free Composed of tinned copper wires Table 207 RS422 Cable requirements 2 3 5 8 3 4 RS485 Bus length and cable ty...

Page 205: ...nterface option they are located above the terminating resistor LED status indicators LED Color Status Explanation On The COM D terminating resistor is enabled L2 Yellow Off The COM D terminating resi...

Page 206: ...ecified for that complete system applies Model number 5ACCIF01 ICAN 000 General information LED status indicators L1 B R ID code 0xE9BB Certifications CE Yes UL cULus E115267 Industrial control equipm...

Page 207: ...that should be accessed I O address 385h data register Access to the register defined in the address register IRQ IRQ10 Interrupt Table 215 I O address and IRQ CAN driver settings The baud rate can b...

Page 208: ...s switched on or off Terminating resistor On The terminating resistor is switched on Off The terminating resistor is switched off Terminating resistor On Off Table 219 Terminating resistor 2 3 5 9 3 2...

Page 209: ...Technical data Panel PC 2100 user s manual V1 17 209 2 3 5 9 3 5 Drivers In Windows 7 and later the CAN IF option is supported by PVI V4 2 5 or Windows CAN driver V3 0...

Page 210: ...nvironmental conditions have already heavily affected and possi bly damaged the device This can result in malfunctions on the device machine or manufacturing system Check the packaging contents and an...

Page 211: ...tout mounting surface are met Permissible deviation from the evenness on the installation cutout 0 5 mm Permissible surface roughness in the area of the mounting seal 120 m Rz 120 Material thickness o...

Page 212: ...ps The number of retaining clips depends on the panel The thickness of the wall or control cabinet plate must be at least 1 mm and is not permitted to exceed 6 mm A 2 5 mm hex screwdriver is needed to...

Page 213: ...ary depending on the panel For the exact number see Fig X AP9x3 panels Installation diagrams on page Figure 113 Inserting the retaining clips sample figure 4 Fasten the retaining clips to the wall or...

Page 214: ...rface tightening screws on an uneven area can result in damage to the display or the ingress of dust and water Procedure 1 Check whether the included mounting screws are screwed into the retaining cli...

Page 215: ...ning clips to the wall or control cabinet by alternately tightening the screws with a 2 5 hex key screwdriver The tightening torque should be max 1 Nm to provide an optimal seal 1 6 mm Wall or control...

Page 216: ...mm A 3 mm hex socket screwdriver is needed to tighten and remove the screw on the clamping block The maximum tightening torque for the screw is 0 5 Nm Devices must be installed on a flat clean and bu...

Page 217: ...tely tightening the screws with a 3 mm hex key screwdriver Tightening the screw presses down the integrated clamping lever to hold the device securely in place The tightening torque should be max 0 5...

Page 218: ...em but as individual components or individual components are installed afterward then these components must be enabled in BIOS This is done by launching BIOS when booting the system loading the defaul...

Page 219: ...following the installation steps in reverse order 4 Place the Panel PC on a clean flat surface 5 Remove the Torx screws T10 indicated in the following image Figure 120 Removing the Torx screws 6 The s...

Page 220: ...F0 and later 5PPC2100 BY11 000 Rev F0 and later 5PPC2100 BY22 000 Rev F0 and later 5PPC2100 BY34 000 Rev F0 and later 5PPC2100 BY44 000 Rev G0 and later 5PPC2100 BY48 000 Rev A0 and later 1 Screw the...

Page 221: ...s section of 0 75 mm2 to 1 5 mm2 and wire end sleeves must be used Installing screw clamp terminal block 0TB103 9 Fasten the wires with wire end sleeves into the terminal contacts as shown in the imag...

Page 222: ...rference for example and not necessarily as a protective measure It therefore serves only to conduct interference not to provide any kind of protection against electric shock This device comes equippe...

Page 223: ...Commissioning Panel PC 2100 user s manual V1 17 223 Power supply connection 24 VDC Pin 2 Ground connection Min 2 5 mm Min 1 5 mm Central grounding point Figure 126 Panel PC 2200 Grounding concept...

Page 224: ...be taken into account when installing or connecting cables Information The maximum tightening torque for the locating screws is 0 5 Nm Bend radius Locating screws Locating screws Figure 127 Bend radi...

Page 225: ...re the device is put into service it must slowly be acclimated to room temperature Subjecting it to thermal radiation is not permitted If transported at low temperatures or if there are large temperat...

Page 226: ...e positioned in different locations depending on the device family Their number as well as the temperature limits also vary depending on the device family For information about the location of tempera...

Page 227: ...and test CDs DVDs available A corresponding load can be generated on the system and peripheral devices based on the extent of the software and existing loopback adapters Information Loopback adapters...

Page 228: ...vailable The USB flash drives must be available in Windows as formatted drives The test USB must then be deselected and the USB flash drives must be configured as the testing device in the disk proper...

Page 229: ...ts The maximum temperature value recorded by each sensor is not permitted to exceed the temperature limits spec ified in the user s manuals If the temperature tests cannot be performed in a climate ch...

Page 230: ...driver must be subsequently installed to operate the touch screen The appropriate driver is available for download in the Downloads section of the B R website www br automation com 3 6 1 4 Windows 7...

Page 231: ...he device Once the installation of Windows 7 has completed the device can be operated immediately 3 6 2 5 Windows Embedded Standard 7 Premium Microsoft multi touch drivers are installed when Windows E...

Page 232: ...4 Set the desired brightness using the slider Figure 131 Adjusting the display brightness Information The changed settings are displayed online but only applied by the system and used after the next...

Page 233: ...t auto If XHCI mode is set to Smart auto in Windows 8 1 or Windows 10 then only USB 2 0 is supported The default value for setting XHCI mode is Smart auto If problems occur during shutdown or rebootin...

Page 234: ...l data for the system unit 4 1 2 BIOS Setup and boot procedure BIOS is activated immediately when switching on the power supply or pressing the power button on the B R industrial PC The system checks...

Page 235: ...t are connected to the system Selecting a device with cursor cursor and then pressing ENTER will boot from that device Pause Pauses POST Pressing any other key resumes POST Table 221 BIOS relevant key...

Page 236: ...System information on page 237 System date The currently configured system date This is re tained when the system is switched off For de tails see the technical data for the system unit Change the sy...

Page 237: ...m information BIOS setting Explanation Configuration options Effect BIOS version Displays the BIOS version None Build time Displays the date the BIOS was created None Processor type Displays the proce...

Page 238: ...on Configures LAN settings Enter Opens this submenu See LAN on page 255 PCI express configura tion Configures PCI Express settings Enter Opens this submenu See PCI express configuration on page 257 US...

Page 239: ...rsion None MTCX firmware version Displays the installed MTCX version None ETH1 MAC address Displays the assigned MAC address for the ETH1 interface None ETH2 MAC address Displays the assigned MAC addr...

Page 240: ...cellaneous configuration BIOS setting Explanation Configuration options Effect Stay off The PC remains switched off on power on After power loss Option for setting the behavior after a power fail ure...

Page 241: ...12 14 15 Manual assignment Disabled Disables this interface Manual Allows manual settings for Base address and IRQ Serial port B Setting for the onboard touch screen Default Uses the default settings...

Page 242: ...lays the B R serial number None Product name Displays the B R model number None Parent device ID Displays the manufacturer number None Parent compatibility ID Displays the manufacturer ID None User se...

Page 243: ...ystem board features Statistical values BIOS setting Explanation Configuration options Effect Total hours Displays the runtime in hours None Power on cycles Displays the number of power cycles Each re...

Page 244: ...s BIOS setting Explanation Configuration options Effect Sensor 1 Displays the current temperature of sensor 1 system unit sensor 2 in C and F sensor near the RAM None Sensor 2 Displays the current tem...

Page 245: ...ys the hardware revision of the panel None Serial number Displays the B R serial number None Product name Displays the B R model number None Parent device ID Displays the manufacturer number None Pare...

Page 246: ...splay board features Statistical values BIOS setting Explanation Configuration options Effect Total hours Displays the runtime in hours None Power on cycles Displays the number of power cycles Each re...

Page 247: ...144 Advanced OEM features Display board features Temperature values BIOS setting Explanation Configuration options Effect Sensor 1 Displays the current temperature of sensor 1 display or panel in C a...

Page 248: ...he panel firmware version None Brightness Sets the display brightness 0 to 100 Sets the brightness in of the selected pan el Settings take effect immediately Fan speed Displays the fan speed of the pa...

Page 249: ...s ID is needed for Au tomation Runtime None Vendor ID Displays the vendor ID None Hardware revision Displays the hardware revision of the IF option None Serial number Displays the B R serial number No...

Page 250: ...es IF board features Statistical values BIOS setting Explanation Configuration options Effect Total hours Displays the runtime in hours None Power on cycles Displays the number of power cycles Each re...

Page 251: ...OCHOT signal initiates temperature throttling to reduce the speed of the CPU and protect it from overheating Enabled Enables this function Allows external services to enable the PRO CHOT signal and th...

Page 252: ...y activating Intel SpeedStep technology Max battery Throttles down the CPU and graphics speed Disabled Disables this function P state reduction Option for reducing CPU performance and pow er usage By...

Page 253: ...of the GTT graphics translation table 2 MB 2 MB GTT 128 MB Reserves 128 MB 256 MB Reserves 256 MB Aperture size Option for configuring the maximum amount of RAM made available to the main memory when...

Page 254: ...o Automatically defines the LFP type based on the EDID data LFP type3 Option for manually setting the LFP local flat panel type VGA 640 x 480 1x18 to WUXGA 1920 x 1200 2x24 Manual setting of the resol...

Page 255: ...S5 Disabled Network stack Item specific help Enable Disable PCE option ROM execution for onboard LAN LAN configuration Figure 152 Advanced LAN BIOS setting Explanation Configuration options Effect Di...

Page 256: ...etwork stack BIOS setting Explanation Configuration options Effect Disabled Disables this function Network stack Option for enabling disabling the UEFI network stack Enabled Enables this function Enab...

Page 257: ...n page 258 PCI Express root port 1 IF1 Configures PCI Express settings on port 1 in terface option Enter Opens this submenu See PCI Express root port 0 to 3 on page 258 PCI Express root port 2 ETH2 Co...

Page 258: ...x speed Option for setting the PCI Express transfer rate Gen2 Maximum transfer rate 5 GT s Disabled Disables this function L0s Enables the L0 energy saving function L0sL1 Automatic assignment of L0s...

Page 259: ...oller Configures USB EHCI controllers for the USB interfaces Enabled Enables the EHCI controller Disabled Hides the BIOS settings for USB port x USB per port control Option for enabling disabling indi...

Page 260: ...internal memory driver for SATA functions which increases the storage performance for random read write ac cess by allowing the drive itself to determine the sequence of commands Enabled Enables hot...

Page 261: ...hat are disabled and configured by Realtime environment are grayed out and can not be changed Disabled Disables this function Hypervisor environment This option configures settings for hypervisor oper...

Page 262: ...r the critical trip point Critical trip point Option for configuring a CPU temperature at which the operating system automatically shuts down Disabled Disables this function 15 C 59 F 23 C 73 F 31 C 8...

Page 263: ...sword entry Set user password1 Function for entering changing or deleting a user password The user password allows only certain BIOS settings to be changed Enter Password entry Minimum password length...

Page 264: ...etting Explanation Configuration options Effect Boot device priority Configures the boot order Enter Opens this submenu See Boot device priority on page 265 Boot configuration Configures the boot sett...

Page 265: ...HDD0 USB CD USB FDD USBHDD P0 USBHDD P1 USBHDD P2 USBHDD P3 ATAPI CD SATA HDD1 PCI LAN0 PCI LAN1 Boot priority order Option for configuring the desired boot order Internal shell Specifies the desired...

Page 266: ...me by skipping some POST procedures Enabled Enables this function Disabled Displays the default logo Enabled Displays the OEM logo Boot logo selection Options for displaying the boot logo Auto Display...

Page 267: ...ption for enabling disabling hotkey recognition from the S4 state Enabled Enables this function The PC exits the S4 state when a key is pressed Disabled Disables this function UEFI boot Option for ena...

Page 268: ...n Yes No Exit discarding changes Selecting this option closes BIOS Setup without saving any changes made Yes No Load setup defaults Selecting this option restores the BIOS default values Yes No Discar...

Page 269: ...address assignments I O address Resource 0000h 00FFh Motherboard resources 02E8h 02EFh COM D optional 02F8h 02FFh COM B optional 0384h 0385h CAN controller optional 03B0h 03DFh Video system 03E8h 03E...

Page 270: ...C 2100 3 Monitor Panel option SDL DVI transmitter SDL3 transmitter 4 If option 5ACCIF01 FPLS 000 5ACCIF01 FPLS 001 COMA 5 IF option 6 PIRQ A For PCIe PCI Express root port 0 VGA controller 7 PIRQ B Fo...

Page 271: ...mponents to BIOS Setup for information about changes see the Readme file for the BIOS upgrade 4 2 1 1 Important information Information Customized BIOS settings are deleted when upgrading BIOS Before...

Page 272: ...nd copy the data to a USB flash drive formatted in FAT16 or FAT32 Alternatively a CFast card can be used 3 Reboot the PC and select UEFI Internal shell as the boot device press key F5 to open the boot...

Page 273: ...ing used The progress indicator is not updated during this time Information The PC s power supply must be switched off and then switched back on again in order for the new firmware to take effect and...

Page 274: ...wing operating systems Windows 10 IoT Enterprise 2016 LTSB Windows 10 IoT Enterprise 2015 LTSB Windows Embedded 8 1 Industry Pro Windows 7 Professional Ultimate Windows Embedded Standard 7 Premium B R...

Page 275: ...ows the most important device functions included in Windows 10 IoT Enterprise 2016 LTSB Function Windows 10 IoT Enterprise 2016 LTSB Range of functions of Windows 10 Enterprise Internet Explorer 11 in...

Page 276: ...edition Windows 10 IoT Enterprise 2016 LTSB does not include applications such as Cortana the Microsoft Edge browser or the Microsoft Store The LTSB version is based on Windows 10 Build 14393and does...

Page 277: ...th 64 bit operating systems 4 5 4 Features The list of features shows the most important device functions included in Windows 10 IoT Enterprise 2015 LTSB Function Windows 10 IoT Enterprise 2015 LTSB R...

Page 278: ...messages which means that it is fully functional at all times Personalization is not possible however e g setting the desktop background The product can be activated at a later time either over the ph...

Page 279: ...ed in detail in the Windows 10 IoT 2015 LTSB working guide It can be downloaded free of charge from the Downloads section of the B R website www br automation com login required Information As a resul...

Page 280: ...unt in the minimum size specified for the data storage device 2 With an active UWF Unified Write Filter 2 GB RAM are recommended The specified memory size is the minimum requirement according to Micro...

Page 281: ...ter UWF must be disabled for this Information Only download necessary drivers from the B R website not from vendor websites 4 6 7 Activation In contrast to previous versions Windows 7 and Windows XP P...

Page 282: ...g the system more secure at the same time They include Unified Write Filter UWF These features make it possible to configure a data storage device e g CFast for read only access or to allow only certa...

Page 283: ...ormous advantage for simple logistical procedures relating to machine automation All Windows operating systems offered by B R are from the Microsoft Embedded division This guarantees much longer avail...

Page 284: ...100 PP500 945GME GM45 QM77 HM76 NM10 US15W Bay Trail SP1 32 bit Multilingual 16 GB 3 1 GB 1 5SWWI7 1400 MUL Ultimate APC810 APC910 APC2100 PPC800 PPC900 PPC2100 945GME Intel Core 2 Duo GM45 QM77 HM76...

Page 285: ...0 PPC2100 or PPC800 devices with an NM10 chipset Information 32 bit operating systems are not recommended for system units with 4 GB or more of main memory For more information see section Miscellaneo...

Page 286: ...1 English PPC2100 License without Recovery DVD Only available with a new device 5SWWI7 1743 MUL Windows Embedded Standard 7 Premium SP1 32 bit Service Pack 1 English PPC2100 License without Recovery...

Page 287: ...ed when it is switched on for the first time This procedure takes approximately 30 minutes with the device being rebooted a number of times Information If Enhanced Write Filter EWF should be used all...

Page 288: ...O systems e g via the fieldbus and other devices interfaces networks etc 4 9 2 Order data Model number Short description Figure Technology Guard 0TG1000 01 Technology Guard MSD 0TG1000 02 Technology...

Page 289: ...etting Advanced Miscellaneous configuration Realtime environment must be set to Enabled Information In order to slightly improve the real time behavior jitter of Automation Runtime Embedded ARemb in g...

Page 290: ...ork protocols are used In place of a cable there is a reserved memory area that is not assigned to either operating system Maximum flexibility The user configures the hypervisor and allocates hardware...

Page 291: ...and much more Complex control algorithms in the form of easy to use software blocks Crane control hydraulics control filter design closed loop design and much more Ad vanced technology made accessible...

Page 292: ...st card 32 GB SLC 5CFAST 032G 10 CFast card 32 GB MLC 5CFAST 064G 10 CFast card 64 GB MLC 5CFAST 128G 10 CFast card 128 GB MLC 5CFAST 4096 00 CFast card 4 GB SLC 5CFAST 8192 00 CFast card 8 GB SLC Tab...

Page 293: ...le on the B R website www br automation com for the necessary B R modifications 4 12 6 Drivers The operating system contains all drivers necessary for operation The most current versions of B R specif...

Page 294: ...GB SLC 5CFAST 8192 00 CFast card 8 GB SLC Table 271 5SWLIN 0743 MUL Order data 4 13 3 Overview Model number Target sys tem Chipset Architec ture Language Minimum size of data storage device Minimum R...

Page 295: ...bsite for the necessary B R modifications www br automa tion com 4 13 6 Drivers Current drivers for all approved operating systems are available in the Downloads section of the B R website www br auto...

Page 296: ...bout possible hardware alarms or error states The hardware components being used include auto matic diagnostic functions in the event of error 4 14 1 Functions Information The functions provided by th...

Page 297: ...tomation Device Interface ADI driver also includes the Control Center and user documentation can be downloaded at no cost from the Downloads section of the B R website www br automation com Informatio...

Page 298: ...Features Header files and import libraries Help files Sample projects ADI DLL for testing applications if no ADI driver is installed The appropriate ADI driver must be installed for the specified prod...

Page 299: ...library Help files the help documentation is in English Sample projects and code snippets ADI DLL for testing applications if no ADI driver is installed The appropriate ADI driver must be installed fo...

Page 300: ...sing a single key Special key functions change brightness etc Assignment of functions to LEDs HDD access power etc 4 assignments possible per key using layers Configuration of the panel locking time w...

Page 301: ...tion directly from a USB flash drive for example An installed ADI driver is required to use the software s full range of functions Figure 171 B R KCF Editor V1 0 screenshot Features Configuration of n...

Page 302: ...PE operating system and the HMI Service Center For details about the HMI Service Center see the HMI Service Center user s manual This can be downloaded for free from the B R website www br automation...

Page 303: ...c compatibility2014 30 EU and are de signed for industrial use EN 61131 2 2007 Programmable logic controllers Part 2 Equipment requirements and tests EN 61000 6 2 2005 Electromagnetic compatibility EM...

Page 304: ...on Ind Cont Eq E115267 Products with this mark are tested by Underwriters Laboratories and listed as indus trial control equipment This mark is valid for the USA and Canada and simplifies the certific...

Page 305: ...cation society Windows 7 operating systems are only permitted to be used as embedded variants For all other B R approved operating systems there are no restrictions The following table lists the revis...

Page 306: ...per C22 2 No 213 16 UL HazLoc certificates are available on the B R website under Downloads Certifi cates HazLoc 5 2 7 1 General safety guidelines PPC2100 systems with AP923 or AP1000 panels that are...

Page 307: ...r un quelconque quipement lorsque le circuit est sous tension moins que la zone soit connue comme tant sans risque et sans concentrations inflammables Risque d explosion Le remplacement de composants...

Page 308: ...arallel con nections Unshielded Ungrounded cables are not permitted to be used in potentially explosive atmos pheres under any circumstances Only configurations with nonincendive USB devices are permi...

Page 309: ...ia B R device connected device Connected nonincendive device with field wiring mouse keyboard Voc Vmax Isc Imax Ca Ci CCable La Li LCable Table 275 Connected nonincendive device with field wiring If t...

Page 310: ...nd and network connections as well as series and parallel con nections Unshielded Ungrounded cables are not permitted to be used in potentially explosive atmos pheres under any circumstances Only conf...

Page 311: ...trical parameters of the cable are unknown the following values can be used Where CCable 196 85 pF m 60 pF ft if unknown Where LCable 0 656 H m 0 20 H ft if unknown Wiring must be performed in accorda...

Page 312: ...n nections Unshielded Ungrounded cables are not permitted to be used in potentially explosive atmos pheres under any circumstances Only configurations with nonincendive USB devices are permitted to be...

Page 313: ...trical parameters of the cable are unknown the following values can be used Where CCable 196 85 pF m 60 pF ft if unknown Where LCable 0 656 H m 0 20 H ft if unknown Wiring must be performed in accorda...

Page 314: ...mp terminal block 3 31 mm 0TB103 91 Connector 24 VDC 3 pin female Cage clamp terminal block 3 31 mm Table 280 0TB103 9 0TB103 91 Order data 6 1 1 3 Technical data Information The following specificati...

Page 315: ...ontact Contact resistance 5 m Operating conditions Pollution degree per EN 61131 2 Pollution degree 2 Table 281 0TB103 9 0TB103 91 Technical data 1 Yes although applies only if all components installe...

Page 316: ...dous locations Class I Division 2 Groups ABCD T41 DNV GL Temperature B 0 55 C Humidity B up to 100 Vibration A 0 7 g EMC B Bridge and open deck 2 Terminal block Note Nominal values according to UL Num...

Page 317: ...ve 6 3 1 2 Order data Model number Short description Figure USB accessories 5MMUSB 2048 01 USB 2 0 flash drive 2048 MB B R 5MMUSB 4096 01 USB 2 0 flash drive 4096 MB B R Table 284 5MMUSB 2048 01 5MMUS...

Page 318: ...te Environmental conditions Temperature Operation 0 to 70 C 2 0 to 70 C 2 Storage 50 to 100 C Transport 50 to 100 C Relative humidity Operation 85 non condensing Storage 85 non condensing Transport 85...

Page 319: ...s Panel PC 2100 user s manual V1 17 319 6 3 1 4 Temperature Humidity diagram Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 172 5MMUSB xxxx 01 Temperature Humidit...

Page 320: ...ditionally executed on the USB flash drive 6 3 2 2 Order data Model number Short description Figure USB accessories 5MMUSB 032G 02 USB 3 0 flash drive 32 GB MLC Table 286 5MMUSB 032G 02 Order data 6 3...

Page 321: ...12192 m Transport Max 12192 m Mechanical properties Dimensions Width 16 58 mm Length 48 30 mm Height 7 60 mm Weight 10 g Manufacturer information Manufacturer Innodisk Manufacturer s product ID DEUA1...

Page 322: ...ies 5ACCUSB4 0000 000 USB hub 4x passive For APC2100 PPC2100 Table 288 5ACCUSB4 0000 000 Order data 6 4 1 3 Technical data Warning Peripheral USB devices can be connected to the USB interfaces Due to...

Page 323: ...characteristics Housing Material Stainless steel coated Coating Anthracite gray Dimensions Width 21 5 mm Height 29 5 mm Depth 97 mm Weight 100 g Table 289 5ACCUSB4 0000 000 Technical data 1 Yes altho...

Page 324: ...HUB 3 Table 290 USB HUB 1 USB HUB 2 USB HUB 3 USB HUB 4 interface 1 The interfaces etc available on the device or module have been numbered as such for the purpose of clear differentiation This number...

Page 325: ...itted to be cleaned when power is switched off in order to prevent unintended functions from being triggered by touching the touch screen or pressing keys Use a moist cloth to clean the device Only us...

Page 326: ...nce is also referred to in the technical literature as burn in effect image retention memory effect memory sticking or ghost image There are basically 2 types Area type This type is characterized by a...

Page 327: ...ector see image with a pointed object such as a pen Figure 175 Replacing a CFast card 7 5 Repairs complaints and replacement parts Danger The unauthorized opening or repair of the device can result in...

Page 328: ...peration touch screen USB redirection Panel locking mechanism configurable using the B R Control Center ADI driver Backlight control of a connected B R display Calculation of statistical data power cy...

Page 329: ...fic tech nical data The value will be provided at a later point in time B10D Number of cycles before 10 of the components have experienced hazardous failure per channel MTTFD Mean time to dangerous fa...

Page 330: ...ex panel overlay 5AP923 1215 00 revision B8 5AP923 1505 00 revision B8 5AP923 1906 00 revision B8 Panel overlay Touch screen Coated front frame Figure 176 Single touch display unit with Autotex panel...

Page 331: ...Panel PC 2100 user s manual V1 17 331 AP9x3 and AP1000 multi touch panels feature an edge to edge glass surface Touch screen Coated front frame Figure 178 Multi touch panel with glass surface sample...

Page 332: ...thyl phthalate Dioxan Dowandol DRM PM Iron chloride FeCl2 Iron chloride FeCl3 Acetic acid 50 Ethyl acetate Linseed oil Aviation fuel Formaldehyde 37 to 42 Glycerine Glycol Isophorone Isopropanol Potas...

Page 333: ...Methylisobutylketone Sodium bisulphate Sodium carbonate Sodium hydroxide 40 Sodium hypochlorite 20 Paraffin oil Phosphoric acid 30 Phthalate Nitric acid 10 Sea water Cutting oil Sulphuric acid 10 Turp...

Page 334: ...Methylbenzene Methylene chloride Methyl ethyl ketone Mineral spirits Motor oil Nitric acid 70 Salt solution 5 tea Turpentine Lubricants Sulphuric acid 40 Cooking oil 3M touch screen multi touch Unless...

Page 335: ...20 to 70 C 40 to 80 C 40 to 80 C Relative humidity Operation Storage Transport 90 at max 50 C 90 RH at max 60 C for 504 hours 90 RH at max 60 C for 504 hours Operating conditions Service life 36 milli...

Page 336: ...ed for example the data specified for that complete system applies Product ID 3M touch screen General information Certifications CE Yes Manufacturer 3M Technology Projected capacitive touch PCT Light...

Page 337: ...to the complete system For the complete system in which this individual component is used for example the data specified for that complete system applies Product ID 3M touch screen General informatio...

Page 338: ...l V1 17 A 5 3 3 Temperature Humidity diagram All values apply to non condensing operation storage transport Temperature C Relative humidity RH non condensing Storage Transport Operation Figure 181 3M...

Page 339: ...s in the B R Key Editor and B R Control Center 58 Figure 24 Representation of keys and LEDs 58 Figure 25 5AP1151 0573 000 Key and LED configuration 58 Figure 26 5AP1180 1043 000 Key and LED configurat...

Page 340: ...1214 000 Dimensions 119 Figure 84 5AP1120 1214 000 Temperature Humidity diagram 120 Figure 85 5AP1120 121E 000 Dimensions 122 Figure 86 5AP1120 121E 000 Temperature Humidity diagram 122 Figure 87 5AP1...

Page 341: ...138 Advanced OEM features Super I O configuration 241 Figure 139 Advanced OEM features System board features 242 Figure 140 Advanced OEM features System board features Statistical values 243 Figure 14...

Page 342: ...74 5ACCUSB4 0000 000 Dimensions 324 Figure 175 Replacing a CFast card 327 Figure 176 Single touch display unit with Autotex panel overlay sample screenshot 330 Figure 177 Single touch display unit wit...

Page 343: ...nd transport 37 Table 24 System units CFast cards interface options Ambient temperature during storage and transport37 Table 25 Temperature sensor locations 39 Table 26 AP9x3 panels Relative humidity...

Page 344: ...data 121 Table 87 5AP1120 121E 000 Technical data 121 Table 88 5AP1130 121E 000 Order data 123 Table 89 5AP1130 121E 000 Technical data 123 Table 90 5AP1120 1505 000 Order data 125 Table 91 5AP1120 1...

Page 345: ...Bus length and transfer rate 169 Table 139 CAN cable requirements 169 Table 140 Terminating resistor 169 Table 141 5ACCIF01 FPCS 000 LED status indicators 170 Table 142 LED Status Error Ethernet mode...

Page 346: ...er rate 197 Table 194 CAN cable requirements 197 Table 195 Terminating resistor 197 Table 196 5ACCIF01 FPSC 001 X2X Link master interface 197 Table 197 5ACCIF01 FPSC 000 LED status indicators 198 Tabl...

Page 347: ...Boot Boot device priority 265 Table 253 Boot Boot configuration 266 Table 254 Exit 268 Table 255 RAM address assignments 269 Table 256 I O address assignments 269 Table 257 IRQ interrupt assignments...

Page 348: ...4096 01 Technical data 317 Table 286 5MMUSB 032G 02 Order data 320 Table 287 5MMUSB 032G 02 Technical data 320 Table 288 5ACCUSB4 0000 000 Order data 322 Table 289 5ACCUSB4 0000 000 Technical data 32...

Page 349: ...0 125 5AP1120 156B 000 135 5AP1120 1906 000 141 5AP1130 0702 000 100 5AP1130 101E 000 104 5AP1130 121E 000 123 5AP1130 156C 000 137 5AP1130 185C 000 139 5AP1151 0573 000 95 5AP1180 1043 000 109 5AP118...

Page 350: ...5SWLIN 0743 MUL 294 5SWUTI 0001 000 302 5SWW10 0243 MUL 277 5SWW10 0543 MUL 275 5SWWI7 1100 ENG 283 5SWWI7 1100 GER 283 5SWWI7 1200 ENG 283 5SWWI7 1200 GER 283 5SWWI7 1300 MUL 283 5SWWI7 1400 MUL 283...

Page 351: ...GNU Linux 294 Backlight 326 Bend radius 224 Bend radius specifications 224 BIOS Advanced 238 Boot 264 Boot configuration 266 Boot device priority 265 CPU configuration 251 CPU power management 252 Di...

Page 352: ...t LED 55 CFast slot 54 Chemical resistance 330 Cleaning 325 Climate chamber 229 COM A IFx 179 184 202 COMD IFx 203 COM IFx 167 190 196 Compatibility 63 Compatibility overview 63 Complaints 327 Complet...

Page 353: ...ectrical components without a housing 13 Individual components 13 Packaging 13 ETH1 51 ETH2 51 Ethernet 1 interface 51 Ethernet 2 interface 51 Ethernet controller 51 51 Ethernet interface Connection a...

Page 354: ...assignments 269 270 K KC 305 KCF Editor 301 Key Editor 300 Known problems 233 L LED 55 LED Link 55 LED Run 55 LED Status 208 LEDs 55 LED status indicator 208 LED status indicators 55 55 163 163 170 17...

Page 355: ...167 174 174 179 184 189 195 System stop error codes 165 172 177 182 187 193 200 POWERLINK 1 IF1 174 POWERLINK 1 interface 174 POWERLINK 2 IFx 174 POWERLINK 2 interface 174 POWERLINK IF1 159 POWERLINK...

Page 356: ...roduct names 63 Single touch 335 Slots 48 Software versions 296 Space for air circulation 26 Spacing specifications for air circulation 29 Standards and guidelines 303 Static wear leveling 147 Switchi...

Page 357: ...hub 322 USB interface 62 USB interfaces 52 323 User serial ID 297 V Vibration 41 41 Viewing angles 329 W W81Ipro 280 Weight 31 WES7 286 Win10 Ent 2015 277 Windows 10 IoT Enterprise 2015 LTSB 277 Wind...

Reviews: