2.2.2.1.3 Maximum ambient temperature for typical operation
Information regarding typical conditions
•
The total power of all system unit USB interfaces is limited to 1 W.
•
2x Gigabit Ethernet
•
No permanent 100% processor load and graphics load
•
The power consumption of the entire system is limited to 45 W. For information about the power consump-
tion of individual components, see
All values apply to non-condensing operation.
E3815
1.46 GHz
E3825
1.33 GHz
E3826
1.46 GHz
E3827
1.75 GHz
E3845
1.91 GHz
E3845
1.91 GHz
All temperature values in degrees
Celsius (°C) at 500 m above sea level, non-condensing
The typical ambient temperature is typically derated by 1°C
per 1000 meters starting at 500 meters above sea level.
5PPC2100.BY01-000
max. 8 W without USB
5P
PC
21
00
.B
Y1
1-
00
0
max. 8 W without USB
5PPC2100.BY22-000
max. 9 W without USB
5PPC2100.BY34-000
m
ax
. 1
1
W
without USB
5PPC2100.BY44-000
max. 13 W without USB
5PPC2100.BY48-000
max. 13 W without USB
Maximum ambient temperature for typical operation
60
60
60
55
55
55
What else can also be operated at the typ.
ambient temperature, or is there a limitation?
Location of sensor(s)
5AP923.1215-00
✓
✓
✓
✓
✓
✓
5AP923.1505-00
✓
✓
✓
✓
✓
✓
5AP923.1906-00 ≤D0
50
50
50
50
50
50
5AP923.1906-00 ≥E0
55
55
55
✓
✓
✓
5AP933.156B-00 ≤C0
50
50
50
50
50
50
5AP933.156B-00 ≥D0
55
55
55
✓
✓
✓
5AP933.185B-00
50
50
50
50
50
50
5AP933.215C-00 ≤C0
40
40
40
40
40
40
5AP933.215C-00 ≥D0
50
50
50
50
50
50
5AP933.240C-00 ≤C0
40
40
40
40
40
40
AP9x3 panels
5AP933.240C-00 ≥D0
55
55
55
✓
✓
✓
5AP1120.0573-000
55
55
55
✓
✓
✓
5AP1151.0573-000
55
55
55
✓
✓
✓
5AP1120.0702-000
✓
✓
✓
✓
✓
✓
5AP1130.0702-000
55
55
55
✓
✓
✓
5AP1120.101E-000
55
55
55
✓
✓
✓
5AP1130.101E-000
55
55
55
✓
✓
✓
5AP1120.1043-000
✓
✓
✓
✓
✓
✓
5AP1180.1043-000
✓
✓
✓
✓
✓
✓
5AP1181.1043-000
✓
✓
✓
✓
✓
✓
5AP1182.1043-000
✓
✓
✓
✓
✓
✓
5AP1120.1214-000
✓
✓
✓
✓
✓
✓
5AP1120.121E-000
✓
✓
✓
✓
✓
✓
5AP1130.121E-000
55
55
55
✓
✓
✓
5AP1120.1505-000
✓
✓
✓
✓
✓
✓
5AP1180.1505-000
✓
✓
✓
✓
✓
✓
5AP1181.1505-000
✓
✓
✓
✓
✓
✓
5AP1120.156B-000
55
55
55
✓
✓
✓
5AP1130.156C-000
55
55
55
50
50
50
5AP1130.185C-000
55
55
55
50
50
50
AP1000 panels
5AP1120.1906-000
55
55
55
✓
✓
S
Display - See temperature sensor position
5CFAST.xxxx-00 ≥Rev. E0
55
55
55
✓
✓
✓
CFast cards
5CFAST.xxxx-10
55
55
55
✓
✓
✓
-
5ACCIF01.FPCC-000
✓
✓
✓
✓
✓
✓
5ACCIF01.FPCS-000
✓
✓
✓
✓
✓
✓
5ACCIF01.FPLK-000
✓
✓
✓
✓
✓
✓
5ACCIF01.FPLS-000
✓
✓
✓
✓
✓
✓
5ACCIF01.FPLS-001
✓
✓
✓
✓
✓
✓
5ACCIF01.FPSC-000
✓
✓
✓
✓
✓
✓
5ACCIF01.FPSC-001
✓
✓
✓
✓
✓
✓
5ACCIF01.FSS0-000
✓
✓
✓
✓
✓
✓
Interface options
5ACCIF01.ICAN-000
✓
✓
✓
✓
✓
✓
-
Table 21: Maximum ambient temperature for typical operation