Technical data
Panel PC 2100 user's manual V1.17
183
2.3.5.5 5ACCIF01.FPLS-001
2.3.5.5.1 General information
Interface option 5ACCIF01.FPLS-001 is equipped with a POWERLINK and RS232 interface. 512 kB of nvSRAM
is also installed.
•
1x POWERLINK interface for managing or controlled node
•
1x RS232 interface
•
512 kB nvSRAM
•
Compatible with APC2100/PPC2100 and APC2200/PPC2200
2.3.5.5.2 Order data
Model number
Short description
Figure
Interface options
5ACCIF01.FPLS-001
Interface card - 1x RS232 interface - 1x POWERLINK interface -
512 kB nvSRAM - For APC2100/PPC2100/APC2200/PPC2200
- Only available with a new device
Optional accessories
Terminal blocks
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block
- Protected against vibration by the screw flange
Table 164: 5ACCIF01.FPLS-001 - Order data
2.3.5.5.3 Technical data
Information:
The following specifications, properties and limit values apply only to this accessory and may deviate
from those that apply to the complete system. For the complete system in which this accessory is
installed, for example, the data specified for that complete system applies.
Model number
5ACCIF01.FPLS-001
General information
LED status indicators
L2, L3
B&R ID code
0xE9B9
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
1)
Controller
nvSRAM
Size
512 kB
Data retention
20 years
Read/Write endurance
Min. 1,000,000
Remanent variables in power failure mode
256 kB
(e.g. for Automation Runtime, see Automation Help)
Interfaces
COM
Quantity
1
Type
RS232, modem supported, not electrically isolated
Design
10-pin, male
UART
16550-compatible, 16-byte FIFO
Max. baud rate
115 kbit/s
POWERLINK
Quantity
1
Transfer
100BASE-TX
Type
Type 4
2)
Design
Shielded RJ45
Transfer rate
100 Mbit/s
Cable length
Max. 100 m between two stations (segment length)
Electrical characteristics
Power consumption
1.5 W
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Table 165: 5ACCIF01.FPLS-001 - Technical data