Technical data
174
Panel PC 2100 user's manual V1.17
Model number
5ACCIF01.FPLK-000
Interfaces
POWERLINK
Quantity
1 (integrated 2-port hub)
Transfer
100BASE-TX
Type
Type 4, redundant
2)
Design
Shielded RJ45
Transfer rate
100 Mbit/s
Cable length
Max. 100 m between two stations (segment length)
Electrical characteristics
Power consumption
1.75 W
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Environmental conditions
Temperature
Operation
-20 to 55°C
Storage
-20 to 60°C
Transport
-20 to 60°C
Relative humidity
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical characteristics
Weight
25 g
Table 147: 5ACCIF01.FPLK-000 - Technical data
1)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
For more information, see Automation Help (Communication - POWERLINK - General information - Hardware - IF / LS).
2.3.5.3.3.1 POWERLINK 1 interface - Pinout
The POWERLINK 1 interface on the system unit is referred to as IF1.
POWERLINK 1 - IF1
1)
Wiring
S/STP (Cat 5e)
Cable length
Max. 100 m (min. Cat 5e)
Status LED
On
Off
Green
See Status/Error LED.
Link LED
On
Off
Yellow
Link (POWERLINK net-
work connection available)
Activity (blinks to indi-
cate active data transfer)
RJ45, female
1
LED "Status"
LED "Link"
Table 148: 5ACCIF01.FPLK-000 - POWERLINK 1 interface
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2.3.5.3.3.2 POWERLINK 2 interface - Pinout
The POWERLINK 2 interface on the system unit is referred to as IFx.
POWERLINK 2 - IFx
1)
Wiring
S/STP (Cat 5e)
Cable length
Max. 100 m (min. Cat 5e)
Status LED
On
Off
Green
See Status/Error LED.
Link LED
On
Off
Yellow
Link (POWERLINK net-
work connection available)
Activity (blinks to indi-
cate active data transfer)
RJ45, female
1
LED "Status"
LED "Link"
Table 149: 5ACCIF01.FPLK-000 - POWERLINK 2 interface
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.