Accessories
Mobile Panel 7200 User's manual V 1.01
71
7.4.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
5CAMPB.0050-10
5CAMPB.0100-10
General information
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
Cable construction
Type
Hybrid cable, 25 wires
Properties
Halogen- and silicone-free
Supply lines
Material
Tinned copper stranded wire
Permissible operating voltage
+30 VDC
Outer jacket
Material
Flame-retardant PUR
Color
Similar to RAL 7012
Cable elements
Control devices
Direct connection between control devices and monitoring device (6 wires)
CAN
2 pairs with shielding (5 wires)
Ethernet
Twisted pair cable for Ethernet (10/100 Mbit/s) (4 wires, male RJ45 connector)
Serial
3 wires
Power supply
+24 VDC supply voltage and grounding (3 wires), SELV
1)
Enable switch
Direct connection between enable switch and monitoring device (6 wires)
Connector
Type
FA. Jacob GmbH type: PERFECT 50.620 M
Electrical properties
Conductor resistance
≤140 Ω/km (0.15 mm² conductor)
≤27 Ω/km (0.75 mm² conductor)
Insulation resistance
≤500 Ω/km
Operating conditions
Flame-retardant
Per IEC 60332-1 and VW1 / FT1 in accordance with C-UL
Shield attenuation
Per IEC 60096-1, Amendment 2
Oil and hydrolysis resistance
Per VDE 0282-10
Ambient conditions
Temperature
Moving
-20 to 60°C
Static
-20 to 80°C
Mechanical properties
Dimensions
Length
5 m ±14 cm
10 m ±20 cm
Diameter
10 mm
Bend radius
Moving
60 mm
Fixed installation
30 mm
Weight
160 g/m
Tension
Max. 140 N
Table 25: 5CAMPB.0050-10, 5CAMPB.0100-10 - Technical data
1)