Technical data
Mobile Panel 7200 User's manual V 1.01
31
2.3.2.2.1.4 Cable construction and cable pinout
6x 0.15 mm²
3x 0.15 mm²
6x 0.15 mm²
3x 0.75 mm²
4x 0.15 mm²
250 mm
5x 0.15 mm²
Cable construction
Receptacle
(1)
for push-
pull locking mechanism
Enabling switch
(2)
, 4 of 6 wires used RS232
(3)
, not used
Control device
(4)
, stop button /
emergency stop, 4 of 6 wires used
Power supply and
grounding
(5)
, 3 wires
Ethernet
(6)
, RJ45 shielded
CAN
(7)
, not used
-
Cable pinout
Receptacle - Pinout
Wire colors
Enable switch (2)
4
Brown
C 1
5
White
NO 1
9
Black
C 2
8
Red
NO 2
Receptacle - Pinout
Wire colors
Control devices (4)
1
Gray-Pink
Stop / Emergency stop normally closed contact 1 (11)
2
Brown-Green
Stop / Emergency stop normally closed contact 2 (21)
15
White-Green
Stop / Emergency stop normally closed contact 1 (12)
16
Red-Blue
Stop / Emergency stop normally closed contact 2 (22)
Receptacle - Pinout
Wire colors
Power supply (5)
3
Red
+24 VDC power supply
14
Black
Ground
17
Gray
Shielding
Receptacle - Pinout
Wire colors
Ethernet (6)
27
Green
Pin 3 (RX)
28
Pink
Pin 1 (TX)
29
Yellow
Pin 6 (RX)
30
Blue
Pin 2 (TX)
Shielding
Shielding
Shielding
Information:
When installing the control cabinet cable, make sure that it is not too loose or too tight in the control
cabinet.