Technical data
30
Mobile Panel 7200 User's manual V 1.01
Model number
5CAMPC.0020-10
Cable elements
Control devices
Direct connection between control devices and monitoring device (6 wires)
(2 wires not used on the MP40/50 and MP7x00)
CAN
2 pairs with shielding (5 wires)
Not used on the MP40/50 and MP7x00
Network
Twisted pair cable for Ethernet (10/100 Mbit/s)
(4 wires, RJ45 connector)
Serial
3 wires
Not used on the MP40/50 and MP7x00
Power supply
+24 VDC supply voltage and grounding (3 wires), SELV
1)
Enable switch
Direct connection between enable switch and monitoring device (6 wires)
(2 wires not used on the MP40/50 and MP7x00)
Connector
Type
Receptacle for push-pull locking mechanism
Operating conditions
Flame-retardant
Per IEC 60332-1 and VW1 / FT1 in accordance with C-UL
Shield attenuation
Per IEC 60096-1, Amendment 2
Oil and hydrolysis resistance
Per VDE 0282-10
Ambient conditions
Temperature
Moving
-5 to 60°C
Static
-20 to 80°C
Mechanical properties
Dimensions
Length
2 m ±0.05 m
Diameter
10 mm
Bend radius
Min. 60 mm
Weight
153 g/m
Tension
Max. 140 N
Table 6: 5CAMPC.0020-10 - Technical data
1)
EN 60950 requirements must be observed.