Technical data • Entire device
Secti
on 2
Te
chn
ica
l da
ta
49
Panel PC 800 User's Manual V 1.00
Ground
The grounding connection is located on the top right on the back of the PPC800 system.
The M4 self-locking nut can be used, for example, to fasten a copper strip that is built into the
PPC800 at a central grounding point in the switching cabinet or system. The largest possible
conductor cross section should be used (at least 2.5 mm²).
Caution!
The pin's connection to the functional ground (pin 2, e.g. switching cabinet) should
be as short as possible. We recommend using the largest possible conductor cross
section on the supply plug.
Figure 11: Ground connection
Ground connection
Summary of Contents for MAPPC800-ENG
Page 2: ...2 Panel PC 800 User s Manual V 1 00...
Page 4: ...4 Panel PC 800 User s Manual V 1 00...
Page 6: ...6 Panel PC 800 User s Manual V 1 00...
Page 16: ...16 Panel PC 800 User s Manual V 1 00 Table of contents...
Page 32: ...32 General information Model numbers Panel PC 800 User s Manual V 1 00...
Page 350: ...350 Accessories Cables Panel PC 800 User s Manual V 1 00...
Page 378: ...378 Appendix A Glossary Panel PC 800 User s Manual V 1 00...
Page 388: ...Table index 388 Panel PC 800 User s Manual V 1 00...