3.5 SDL flex cables with extender
3.5.1 5CASDL.0xx0-13
3.5.1.1 General information
5CASDL.0xx0-13 SDL flex cables with an extender are designed for use in both inflexible and flexible applications
(e.g. support arm systems).
Caution!
Power must be turned off before plugging in and unplugging cables.
3.5.1.2 Order data
Model number
Short description
Figure
SDL flex cable
5CASDL.0300-13
SDL flex cable with extender, 30 m
5CASDL.0400-13
SDL flex cable with extender, 40 m
5CASDL.0430-13
SDL flex cable with extender, 43 m
Table 58: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Order data
3.5.1.3 Technical data
Product ID
5CASDL.0300-13
5CASDL.0400-13
5CASDL.0430-13
General information
Certification
CE
Yes
cULus
Yes
GL
Yes
1)
Cable structure
Wire cross section
AWG 24 (control wires)
AWG 26 (DVI, USB, data)
Properties
Silicone- and halogen-free
Shielding
Individual cable pairs and entire cable
Cable shielding
Aluminum-clad foil + tinned copper mesh
Outer sheathing
Material
Special TMPU - semi gloss
Color
Black
Labeling
(B&R) SDL cable (UL) AWM 20236 80°C 30V E63216
Connector
Type
2x DVI-D (24+1), male
Connection cycles
Min. 200
Contacts
Gold-plated
Mechanical protection
Metal cover with crimped stress relief
Locating screw tightening torque
Max. 0.5 Nm
Electrical characteristics
Operating voltage
≤30 V
Test voltage
Wire/Wire
1 kV
Wire/Shield
0.5 kV
Wave impedance
100 ±10 Ω
Conductor resistance
AWG 24
≤95 Ω/km
AWG 26
≤145 Ω/km
Insulation resistance
>200 MΩ/km
Operating conditions
Approbation
UL AWM 20236 80°C 30 V
Flame resistant
In accordance with UL758 (cable vertical flame test)
Oil and hydrolysis resistance
In accordance with VDE 0282-10
Environmental conditions
Temperature
Storage
-20 to 60°C
Fixed installation
-20 to 60°C
Flexible installation
-5 to 60°C
Table 59: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data