background image

 

ETAL210.1050-1 user's manual V1.00

1

ETAL210.1050-1

User's manual

Version:

1.00 (April 2020)

Order no.:

User's manual

Translation of the original documentation

B&R reserves the right to make changes to the content without prior notice. B&R assumes no liability for typo-

graphical errors or for any other information in this document as far as legally possible. Liability claims against B&R

regarding the content of delivery and documentation of third-party components used in the product are excluded

in any case. The user is responsible for compliance with all relevant and professionally pertinent safety measures

as well as the intended use. B&R points out that the software and hardware designations and brand names of the

respective companies are subject to the legal protection regulations of intellectual property law.

Summary of Contents for ETAL210.1050-1

Page 1: ...n in this document as far as legally possible Liability claims against B R regarding the content of delivery and documentation of third party components used in the product are excluded in any case Th...

Page 2: ...lectronics 7 4 Responsibilities of the operator 7 Chapter 4 System characteristics 8 1 General information 8 2 Order data 8 3 Content of delivery 8 Chapter 5 Technical data 10 Chapter 6 Commissioning...

Page 3: ...ctions or situations Signal word Description Danger Failure to observe these safety guidelines and notices will result in death severe injury or substantial damage to property Warning Failure to obser...

Page 4: ...for proper ESD handling Electrical assemblies with housing Do not touch the connector contacts of connected cables Do not touch the contact tips on circuit boards Electrical assemblies without housin...

Page 5: ...longer ensure sufficient cooling The presence of aggressive gases in the environment can also result in malfunctions In combination with high temperature and relative humidity aggressive gases for ex...

Page 6: ...sses resulting from for example IT security breaches unauthorized access digital intrusion data leakage and or data theft Before B R releases products or updates they are subjected to appropriate func...

Page 7: ...wired and prepared for use No additional wiring examples are required The power supply and communication e g Ethernet are implemented via cables with standard connector systems such as RJ45 Caution El...

Page 8: ...y expandable with other ETA light systems via POWERLINK compact dimensions Required accessories ETAL100 0000 2 Black coated wooden plate with B R logo two milled grooves for holding ETA light systems...

Page 9: ...Content of delivery Chapter 4 System characteristics ETAL210 1050 1 user s manual V1 00 9 X20CP1586 5CFCRD 0512 06 ETAL100 3200 12 For details and additional technical data see the data sheets for th...

Page 10: ...pply Connection Low voltage female connector 5 5 mm 2 1 mm 0TP650 07 Mechanical properties Dimensions Width 300 mm Height 230 mm Depth 90 mm Weight 1 4 kg Brief overview Content of delivery This produ...

Page 11: ...ble 0TP370 76 1x module bracket ETAL100 0000 2 Controller such as PowerPanel or an X20 controller Advice When combining with other products from the ETA light system product portfolio you may need ad...

Page 12: ...s emergency stops or emergency stop buttons remain accessible Caution Danger of falling Loose cables can result in injuries Make sure that the cables are laid cleanly 3 Safety Check the following elem...

Page 13: ...switched on can result in sparking Always connect the power supply unit to the product first then to the power supply This prevents sparking and the resulting personal injury or material damage 5 Mem...

Page 14: ...er ies average service life and operating conditions They do not correspond to the maximum buffer duration The CPUs are equipped with a lithium battery The lithium battery is located in a separate com...

Page 15: ...ely Warning Personal injury and damage to property due to unauthorized repair work or tampering Do not carry out any repair work on B R products B R products are only permitted to be repaired by train...

Page 16: ...stem product portfolio you may need ad ditional components For additional information see the documentation of the product used 1 1 0TP370 76 1 1 1 General information Cold appliance power supply cabl...

Page 17: ...ction via IEC 320 C14 Fully enclosed plastic housing 1 2 2 Order data Model number Short description Figure Accessories 0TP650 07 Wide range desktop power supply unit for office and laboratory use out...

Page 18: ...tem modules Sturdy wooden base plate Possible to connect up to 2 ETA light system modules Compact dimensions 1 3 2 Order data Model number Short description Figure ETAL100 0000 2 Black coated wooden p...

Page 19: ...0AI2222 ETAL120 1050 1 Keypad module prewired for X20CPx5xx Completely wired No additional power supply required 2 buttons 2 maintained buttons Each with 1 red 1 yellow and 1 green illuminated actuato...

Page 20: ...ssories Optional accessories 20 ETAL210 1050 1 user s manual V1 00 Model number ETAL120 1050 1 Mechanical properties Dimensions Width 300 mm Height 90 mm Depth 70 mm Table 10 ETAL120 1050 1 Technical...

Page 21: ...tion with other X20 components is possible in principle but requires a thorough examination of whether the I O configuration matches the wiring of this product Information Check whether the terminal b...

Page 22: ...del number Short description Figure Accessories ETAL100 1Y05 0 ETA light system Y current distributor for connecting two ETA light systems to a desktop power supply unit 1x DC 5 5 x 2 1 mm female conn...

Page 23: ...r s manual V1 00 23 2 3 POWERLINK cables Short description Length POWERLINK cables 0 5 m X20CA0E61 00050 1 m X20CA0E61 00100 1 5 m X20CA0E61 00150 2 m X20CA0E61 00200 Length Tolerances for cable lengt...

Page 24: ...10 1050 1 user s manual V1 00 2 5 X20CA0E61 xxxxx Dimensions Length xxxx 47 Pinout Male RJ45 connector Male RJ45 connector 1 8 Shield White Orange Orange White Green Blue White Blue Green White Brown...

Page 25: ...ble controllers Part 2 Equipment requirements and tests EN 61000 6 2 2005 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for in dustrial environments EN 61000 6 4 2007 Electroma...

Page 26: ...ible 1 Separation of materials To ensure that devices can be recycled in an environmentally friendly manner it is necessary to separate out the different materials Component Disposal Programmable logi...

Page 27: ...Publishing information Publishing information ETAL210 1050 1 user s manual V1 00 27...

Page 28: ...information 28 ETAL210 1050 1 user s manual V1 00 Publishing information B R Industrial Automation GmbH B R Strasse 1 5142 Eggelsberg Austria Telephone 43 7748 6586 0 Fax 43 7748 6586 26 office br aut...

Reviews: