Technical data • Fully assembled device
Chapter 2
Technical data
Automation PC 810 with GM45 CPU board user's manual V1.28
49
2.6.4 Monitor/Panel connection - SDL (Smart Display Link / DVI)
Monitor/Panel connection - SDL (Smart Display Link) / DVI
The following is an overview of the video signals available on the monitor/panel output.
For details, see the technical data for the CPU board being used.
CPU board
Video signals with all system unit variants
5PC800.BM45-00
RGB, DVI, SDL
5PC800.BM45-01
RGB, DVI, SDL
Table 17: Monitor/Panel connection - RGB, DVI, SDL
2.6.4.1 Pinout
Pin Assignment
Description
Pin Assignment
Description
1 TMDS data 2-
DVI lane 2 (negative)
16 HPD
Hot plug detect
2 TMDS data 2+
DVI lane 2 (positive)
17 TMDS data 0-
DVI lane 0 (negative)
3 TMDS data 2/4
SHIELD
Shield for data pair 2 and 4
18 TMDS data 0+
DVI lane 0 (positive)
4 SDL-
SDL lane (negative)
19 TMDS Data 0/
XUSB1 SHIELD
Shield for data pair 0 and
USB1
5 SDL+
SDL lane (positive)
20 XUSB1-
USB lane 1 (negative)
6 DDC clock
DDC-based control signal
(clock)
21 XUSB1+
USB lane 1 (positive)
7 DDC data
DDC-based control signal
(data)
22 TMDS clock
shield
Shield for clock pair
8 NC
Not connected
23 TMDS clock+
DVI clock (positive)
9 TMDS data 1-
DVI lane 1 (negative)
24 TMDS clock -
DVI clock (negative)
10 TMDS DATA 1+ DVI lane 1 (negative) HDMI
clock (positive)
C1 ANALOG RED Analog red
11 TMDS DATA 1/
XUSB0 SHIELD
Shield for data pair 1 and
USB0
c2 ANALOG
GREEN
Analog green
12 XUSB0-
USB lane 0 (negative)
C3 ANALOG BLUE Analog blue
13 XUSB0+
USB lane 0 (positive)
C4 ANALOG
HORZ SYNC
Analog horizontal synchro-
nization
14 +5 V power
1)
+5 V power supply
C5 ANALOG GND Analog ground (return for R,
G and B signals)
15
Ground (return
for +5 V, HSync
and VSync)
Ground
DVI 24-pin, female
6 7 8
5
1 2 3 4
14 15 16
13
9 10 11 12
22 23 24
21
17 18 19 20
c1
c4
c2
c3
c5
Table 18: Pinout - DVI connection
1)
Protected internally by a multifuse.
2.6.4.2 Cable lengths and resolutions for SDL transmission
The following table lists the relationship between segment lengths and maximum resolution depending on the SDL
cable being used:
Resolution
SDL cables
Segment length [m]
VGA
640 x 480
SVGA
800 x 600
XGA
1024 x 768
SXGA
1280 x 1024
UXGA
1600 x 1200
FHD
1920 x 1080
1.8
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5CASDL.0018-00
5CASDL.0018-01
5CASDL.0018-03
5
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
5CASDL.0050-00
5CASDL.0050-01
5CASDL.0050-03
10
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
5CASDL.0100-00
5CASDL.0100-01
5CASDL.0100-03
15
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
5CASDL.0150-00
5CASDL.0150-01
5CASDL.0150-03
-
-
-
-
-
5CASDL.0150-03
20
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
5CASDL.0200-00
5CASDL.0200-03
-
-
-
5CASDL.0200-03
25
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
5CASDL.0250-00
5CASDL.0250-03
-
-
-
-
-
-
30
5CASDL.0300-00
5CASDL.0300-03
5CASDL.0300-00
5CASDL.0300-03
-
5CASDL.0300-13
-
5CASDL.0300-13
-
-
-
5CASDL.0300-13
40
5CASDL.0400-13
5CASDL.0400-13
5CASDL.0400-13
5CASDL.0400-13
-
5CASDL.0400-13
Table 19: Cable lengths and resolutions for SDL transmission