Software • B&R Automation Device Interface (ADI) - Control Center
Chapter 4 Software
Automation PC 810 with GM45 CPU board user's manual V1.28
281
Deleting the data in flash memory can take several seconds depending on the memory block being used. The
progress indicator is not updated during this time.
Information:
The UPS is automatically restarted after a successful download. This can cause a brief failure in the
UPS communication.
9.4.5 Saving the UPS battery settings
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.
3. Under Battery settings, click on
Save
. "Save under" dialog box opened.
4. Enter a file name or select an existing file and click on
Save
.
Information:
UPS settings can only be saved using UPS firmware version 1.10 and higher.
The transfer can be aborted by clicking on
Cancel
in the Download dialog box.
9.4.6 Configuring UPS system settings
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.
3. Under
UPS settings
, click on
Change
. This opens the following dialog box:
Figure 153: ADI Control Center - UPS settings
Further information regarding the UPD system settings can be found in the Windows help.
Information:
•
UPS settings can only be changed using UPS firmware version 1.10 and higher. If there are no
changed settings on the UPS, then the factory or default settings are used.
•
The UPS is automatically restarted after UPS settings have been changed. This can cause a
brief disruption in communication with the UPS.
•
Administrator rights are required in order to change the energy options or display the UPS
status.