Software • BIOS options
236
Automation PC 810 with GM45 CPU board user's manual V1.28
1.4.13.3 Legacy Devices
Figure 130: GM45 Legacy Devices
BIOS setting
Description
Configuration options
Effect
Enabled
Enables the interface
COM A
Settings for the serial
COM1
interface in the sys-
tem.
Disabled
Disables the interface
Base I/O address
Selects the base I/O address for the COM port
238, 2E8, 2F8,
328, 338, 3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM port.
IRQ 3, IRQ 4, IRQ 5, IRQ 6,
IRQ 7, IRQ 10, IRQ 11, IRQ 12
Selected interrupt is assigned.
Disabled
Disables the interface
COM B
Setting for the
COM2
serial interface in the sys-
tem.
Enabled
Enables the interface
Base I/O address
Selects the base I/O address for the COM port
238, 2E8, 2F8,
328, 338, 3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM port.
IRQ 3, IRQ 4, IRQ 5, IRQ 6,
IRQ 7, IRQ 10, IRQ 11, IRQ 12
Selected interrupt is assigned.
Enabled
Enables the interface
COM C
Setting the COM port for the
touch screen on
the monitor/panel
connector.
Disabled
Disables the interface
Base I/O address
Selects the base I/O address for the COM port
238, 2E8, 2F8,
328, 338, 3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM port.
IRQ 3, IRQ 4, IRQ 5, IRQ 6,
IRQ 7, IRQ 10, IRQ 11, IRQ 12
Selected interrupt is assigned.
Enabled
Enables the interface
COM D
Sets the COM port for the
touch screen on the
AP Link
connector.
Disabled
Disables the interface
Base I/O address
Selects the base I/O address for the COM port
238, 2E8, 2F8,
328, 338, 3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM port.
IRQ 3, IRQ 4, IRQ 5, IRQ 6,
IRQ 7, IRQ 10, IRQ 11, IRQ 12
Selected interrupt is assigned.
Enabled
Enables the interface
COM E
Configuration of the COM port on the
B&R add-
on interface
5AC600.485I-00 (IF option).
Disabled
Disables the interface
Base I/O address
Selects the base I/O address for the COM port
238, 2E8, 2F8,
328, 338, 3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM port.
IRQ 3, IRQ 4, IRQ 5, IRQ 6,
IRQ 7, IRQ 10, IRQ 11, IRQ 12
Selected interrupt is assigned.
Disabled
Disables the interface
CAN
Configuration of the CAN port of the
B&R add-
on CAN interface card
5AC600.CANI- 00 (IF op-
tion).
Enabled
Enables the interface
Base I/O address
Selection of the base I/O address for the CAN
port.
None
-
Interrupt
Selection of the interrupt for the CAN port.
IRQ 10, NMI
Selected interrupt is assigned.
Disabled
Disables the interface
Hardware Security Key
Settings for the hardware security key (Dongle)
are made here.
Enabled
Enables the interface
Table 195: GM45 Legacy Devices (Setting options)