5.11 Six AP900 and two AP800 units via onboard SDL and SDL AP Link
Three Automation Panel 900 (max. UXGA) units and one Automation Panel 800 are connected to the integrated
SDL interface (onboard) via SDL. Additionally, three Automation Panel 900 (max. UXGA) units and one Automation
Panel 800 are operated on the optional SDL transmitters. The Automation Panels in each line must be the same
type. The two lines show different content (Extended Desktop), but displays in the same line show the same content
(Display Clone).
USB is supported up to a maximum distance (segment 1 + segment 2) of 30 m on the first two displays. Starting
at a distance of 30 m, USB is only available on the first display (front and back) up to a maximum of 40 m. USB
devices can only be connected directly to Automation Panel 900 devices (without a hub).
Automation Panel 800
No USB
possible
Automation Panel 800
No USB
possible
Link: 5DLSDL.1000-01
Link: 5DLSDL.1000-01
USB
possible
USB OK
Link: 5DLSDL.1000-01
Link: 5DLSDL.1000-01
No USB
possible
1
Link: 5DLSDL.1000-01
USB
possible
SDL Segment 1
Max. 40 m
Link: 5DLSDL.1000-01
USB OK
SD
L
Se
gm
en
t 2
M
ax
. 4
0
m
SDL Segemt1
Max. 40 m
SD
L
Se
gm
en
t 3
M
ax
. 4
0
m
SD
L
Se
gm
en
t 4
M
ax
. 4
0
m
SD
L
Se
gm
en
t 2
M
ax
. 4
0
m
SD
L
Se
gm
en
t 3
M
ax
. 4
0
m
SD
L
Se
gm
en
t 4
M
ax
. 4
0
m
Automation PC 810
With AP Link
5AC801.SDL0-00
No USB
possible
SDVO-C
SDVO-B
Internal device number on the APC
Independent of segment length
Depends on segment length
Not supported
AP Link
Connection
Monitor / Panel
Connection
Figure 93: Six AP900 and two AP800 units via onboard SDL and SDL AP Link (sample photo)
5.11.1 Basic system requirements
The following table shows the possible combinations of APC810 system unit and CPU board to implement the
configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this is
also indicated (e.g. when connecting a non-B&R Automation Panel 900 device).
with system unit
CPU board
5PC810.SX01-00
1)
5PC810.SX02-00
5PC810.SX03-00
5PC810.SX05-00
Limitation
Resolution
5PC800.BM45-00
-
✓
✓
✓
Max. UXGA
5PC800.BM45-01
-
✓
✓
✓
Max. UXGA
Table 166: Possible combinations of system unit and CPU board
1)
AP Link cannot be installed.