Technical data • Individual components
134
Automation PC 810 with GM45 CPU board user's manual V1.28
Product ID
5ACPCI.RAIC-03
Manufacturer information
Manufacturer
Fujitsu
Manufacturer product ID
M120-ESW MHY2160BH-ESW
Recommendations
Specified standard
CE (CE)
Yes
Recommendations
Specified standard
CE (CE)
Yes
Table 82: 5ACPCI.RAIC-03 - Technical data
1)
Temperature values for 305 meter altitude. The temperature specification must be reduced linearly by 1 °C every 305 meters. The temperature increase
and decrease can be a maximum of 3°C per minute.
2)
Standard operation means 333 POH (power-on hours) per month.
3)
24-hour operation means 732 POH (power-on hours) per month.
4)
Maximum humidity at 29°C.
5)
Maximum humidity at 40°C.
6)
Operation in areas prone to vibration and shock can affect performance negatively (reduction of transfer rate).
7)
Mounted on PCI insert.
3.6.13.4 Temperature humidity diagram
Temperature [°C]
R
el
at
iv
e
hu
m
id
ity
[%
R
H
] (
no
n-
co
nd
en
si
ng
)
Operation
St
or
ag
e
/ T
ra
ns
po
rt
Figure 53: 5ACPCI.RAIC-03 - Temperature humidity diagram
3.6.13.5 Driver support
Special drivers are necessary for operating the PCI SATA RAID controller. Drivers for supported and approved
operating systems are available in the Downloads section of the B&R website (
The .NET-based SATA Raid™ serial ATA RAID management software can also be found on the B&R homepage.
Information:
Required drivers can only be downloaded from the B&R website, not from manufacturer websites.
3.6.13.6 Configuration
Configuring a SATA RAID network: see Chapter 3 "Commissioning", section 7 "Configuration of a SATA RAID
3.6.13.7 Exchanging a HDD
A hard drive can be easily exchanged in the event of an error when using the RAID1 (mirroring) configuration
without having to re-install the system. The replacement SATA HDD 160GB 5ACPCI.RAIC-04 is available as a
replacement part for a HDD.
For instructions on exchanging the drive, see chapter Chapter 7 "Maintenance / Service", section 11 "Exchanging