ELECTRICAL CONNECTIONS 

 

To guarantee the safety of operator and to prevent damages to components, while caring out the connections or inserting 

the radio receiver, the control unit must be disconnected from electric feeding.  

 

 

For feeding cables, motors lines, lines for blinker/ courtesy light, electric lock use a cable with appropriate section to the length of the connection 

(min 1,5mmq). For auxiliary feedings of commands and the safety contacts, use minimum section of 0.5mmq. In case those cables are too long 
(beyond 30m), it’s better to do a decoupling by setting up relays on the control unit. 

 

In case of intervention of a fuse, after removing the problem, change it by another with the same characteristics.  

 

Install safety devices, limit switches, photocells, rubber edges and Stop pushbutton.  

 

If one or more safety devices are not installed, short-circuit the relative clamps with the common of the commands.  

 

All contacts N.C. dress to the same input must be connected in series.  

 

All contacts N.A. dress to the same input must be connected in parallel. 

 

Preview disconnecting devices on the feeding line in an accessible place. For the feeding of the control unit set an appropriate external discon-

necting device (not included with equipment 

 

Hold the cables of feeding separated from those of the encoder with a distance between motor and control unit of maximum 10m. Don’t use 

multi pole cables. 

 

 

 

 

Functioning of the Electric lock output, ELS: connect it between clamp N.10 and clamp N.11 –when an opening command is given, 1s of switch-

ing on is executed before the activation of M1 

 

Functioning of flashing light: connect it between clamp N.11 and clamp N.12, maximum power 25W 24Vdc. In opening and in closing, it execute 

a forewarn of 1,5s to signal that the automation is starting the movement. 

 

Functioning of “phototest” on the feeding of photocell TX: if you want to execute a phototest cycle on every opening, set Dip 8 = ON and connect 
the NEGATIVE feeding of the photocell emitter to clamp N.13 

 
 

CONNECTION OF MOTORS ELECTRIC FEEDING  

 

 

Motor M1 : connect between clamp N.6 and clamp N.7 

 

Motor M2 : connect between clamp N.8 and clamp N.9 – Motor M2 in closing, start first. 

 

 

Summary of Contents for AK-224

Page 1: ...th motors Flashing light 25W 24Vdc Tension of operation 24Vdc Working time 0 120s Absorbed current 5A max Automatic closing time 0 120s Absorbed power 120W max Forewarn 1 5s Force 1200N Temperature of exercise 20 C 70 C Opening time 11 5s Protection grade IP56 Opening of the leaf 90 100 Max length of the leaf 2m Temporary service 80 ...

Page 2: ... a maximum length of 2m The motor can be installed even at the right then at the left side of the gate The device must be destined exclusively to the usage it was con ceived for Any other usage is to be considered improper and therefore dangerous Control pushbuttons have to be installed at an height between 1 5m and 1 8m in a position not accessible by children or under age in direct view of the g...

Page 3: ...ning as during closing If stopped in any position it has no to move During movement it must not skid WARNING It is forbidden to put in service the automation before the machine in which it will be incorporate has been de clared complying to dispositions of the directive CEE 22 06 98 ASSEMBLING Open the package and verify that all the elements which compose the automation are in good status UNLOCKI...

Page 4: ...CABAT 30 12 Pin RESET short circuit in case of total cancellation of memorized run VISIBLE CONTROL ON THE STATE OF THE UNIT The control unit is designed with the aim to complete the installation in the shortest time possible and therefore to immediately see if the connections are correct through the switching on of corresponding LEDs A Red Led signal the presence of feeding DL1 POWER it indicates ...

Page 5: ...ll contacts N A dress to the same input must be connected in parallel Preview disconnecting devices on the feeding line in an accessible place For the feeding of the control unit set an appropriate external discon necting device not included with equipment Hold the cables of feeding separated from those of the encoder with a distance between motor and control unit of maximum 10m Don t use multi po...

Page 6: ...een ClampN 14 and Clamp N 19 Contact N A Normally open It s a command for opening that in case we set the functioning with 2 motors will make motor M1 open completely If we selected to function with only one motor will do a partial opening of the 40 of the run Functioning Step Step P P Connect between ClampN 15 and Clamp N 19 Contact N A Normally open It s a commando for opening that works in two ...

Page 7: ...ly closed it will open first motor M1 and then motor M2 to reach the mechanical stop in maximum opening all the learning procedure of mechanical stops is execute in slowing down The first manoeuvre that execute the control unit is a closing one this is done in order to make the installer understand if the two wires of the motors are connected in the right way If a closing doesn t take place do a r...

Page 8: ...ispose in the environment Find out about the method for recycling or disposing of the product in compliance with current local laws NOTES PROGET srl Via Europa 3 31047 Ponte di Piave TV ITALY tel 39 0 422 857377 fax 39 0 422 857367 web http www proget beb com email proget proget beb com rev 1 0 3 04 2009 ...

Reviews: