Programming guidelines
228
ACOPOSinverter P84 User's Manual 2.10
2.8.11.12 Load measurement
Based on the information of a load sensor, this function adapts to the current
[brake engaging current]
(Ibr)
of
the function
[BRAKE LOGIC]
(bLC-)
. The signal from the load sensor can be assigned to an analog input (usually
a 4 - 20 mA signal) or to the encoder input, according to the type of load sensor.
Examples:
•
Measurement of the total weight of a hoisting winch and its load
•
Measurement of the total weight of the elevator gear units, the cab and the counterweight.
The current
[brake engaging current]
(Ibr)
is adjusted according to the following characteristic.
Ibr
[Pkt 2y]
(CP2)
[Pkt 1y]
(CP1)
[Load measure. Pkt 1X]
(LP1)
Zero load
100%
0
Signal
Load sensor
[Load measure Pt 2x]
(LP2)
This curve can represent a load sensor on an elevator gear unit for which the motor load zero occurs when the
load in the cab is not zero.