Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
213
2.8.11.8 +/- speed
Two types of operation are available.
1.
Use of single action pushbuttons:
Two logic inputs are required in addition to rotational direction(s).
The input set to "+ speed" increases the speed, and the input set to "- speed" reduces the speed.
2.
Use of dual action pushbuttons:
Only one logic input, that is assigned to "+ speed", is required.
+/- speed with dual-action buttons:
Description: 1 button that can be pressed twice (2 steps) for each direction of rotation. A contact closes each time
the button is pressed.
Released:
(- Speed)
1. Press
(Speed maintained)
2. Press
(faster)
Forward button
–
a
a and b
Reverse button
–
c
c and d
Connection example:
Control terminal bar
ACOPOSinverter P84
Ll1 Llx Lly +24
a
b
c
d
Ll1: Forward
Llx: Reverse
Lly: + Speed
Do not use this "+/-speed" type with 3-wire control.
In both cases, the maximum speed is specified by
[high speed]
(HSP)
.
Note:
In the event of a reference changeover by rFC from any reference channel to a different reference
channel with "+/- Speed" the value of the reference
[Motor speed]
(rFr)
(after ramp) can be copied at the
same time in accordance with the parameter
[channel copy 1 → 2]
(COP)
. The value of the reference
rFr
(after ramp) copied.
This prevents the speed being incorrectly reset to zero when switching takes place.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...