Programming guidelines
144
ACOPOSinverter P84 User's Manual 2.10
Code
Name/Description
Setting range
Factory settings
SdC1
[Auto DC inj. level 1]
0 to 1.2 In
1)
0.7 In
1)
Level of standstill DC injection current. This parameter can be activated if
[Auto DC injection]
see "[Auto DC injection] AdC-" on page
is not set to
[No]
(nO)
.
For this parameter, the value 0 will be forced if
[Motor control type]
(Ctt)
,
see "Drive parameters (Ctt)" on page 153
=
[Sync. Motor.]
(SYn)
.
Caution!
Check that the motor will withstand this current without overheating.
Failure to follow this instruction can result in equipment damage.
tdCI
[Auto DC inj. time 1]
0.1 to 30 s
0.5 s
Standstill injection time.
This parameter can be activated if
[Auto DC injection]
(AdC)
see "[Auto DC injection] AdC-" on page 208
[No]
(nO)
.
If
[Motor control type]
(Ctt)
page 63 on
[FVC]
(FUC)
or
[Sync. Motor.]
(SYn)
is set, this time is the hold time at zero speed.
SdC2
[Auto DC inj. level 2]
0 to 1.2 In
1)
0.5 In
1)
2. Level of standstill DC injection current.
This parameter can be activated if
[Auto DC injection]
(AdC)
see "[Auto DC injection] AdC-" on page 208
[No]
(nO)
.
For this parameter, the value 0 will be forced if
[Motor control type]
(Ctt)
,
see "Drive parameters (Ctt)" on page 153
=
[Sync. Motor.]
(SYn)
.
Caution!
Check that the motor will withstand this current without overheating.
Failure to follow this instruction can result in equipment damage.
tdC2
[Auto DC inj. time 2]
0 to 30 s
0 s
2. Standstill injection time.
This parameter can be activated if
[Auto DC injection]
(AdC)
see "[Auto DC injection] AdC-" on page 208
[Yes]
(YES)
1)
In is the same as the rated current specified in the installation instructions or on the nameplate of the inverter.
AdC
SdC2
Function
YES
x
Ct
≠ 0
Ct
= 0
Movement command
Frequency
Note:
If
[Motor control type]
(Ctt)
see "Drive parameters (Ctt)" on page 153
) is set to
[FVC]
(FUC)
:
[I DC auto
braking 1]
(SdC1)
,
[I DC auto braking 2]
(SdC2)
and
[time aut. DC brake2]
(tdC2)
cannot be activated.
Only
[time aut. DC brake 1]
(tdC1)
can be activated. This is then a hold time at zero speed.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can also be
accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed in these menus, on
the pages indicated, to aid programming.
Summary of Contents for 8I84T200037.01P-1
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...