Accessories
Mobile Panel 7100 User's manual 1.51
137
6.3.2.4 Dimensions
74
.2
ø9
ø 4.5
M5 (10 deep)
6.3.2.5 Drilling template 4MPCBX.0000-01
90
50
12
5
M5 (10 deep)
11
.5
13
.5
Mounting holes, rear
26
10
0
77
90
ø 9
ø 4.5
24
Mounting holes, front
Opening at bottom
Opening at bottom
6.3.2.6 Content of delivery
Quantity
Component
1
Connection box 4MPCBX.0001-00
Table 52: 4MPCBX.0001-00 - Content of delivery
6.4 Box cables
6.4.1 5CAMPB.0xxx-10
6.4.1.1 General information
A box cable establishes the electrical connection between the control cabinet and connection box
4MPCBX.0000-00. It includes lines for the network (Ethernet 10/100 Mbit/s), +24 VDC power supply, control de-
vices or stop / emergency stop and key switches or pushbuttons, enable switches, serial transfer and CAN.
The connection side has a pre-assembled RJ45 Ethernet connection. The remaining cables are open with wire
end sleeves to simplify further wiring to the safety equipment and other connections. The box cable is installed in
the connection box on the other side (connection box side).
The pinout of the RJ45 Ethernet connection (crossover) permits direct connection to a B&R controller. If an Ethernet
hub is used, it must support crossover RX and TX lines.