Commissioning
70
Mobile Panel 40/50 User's manual V1.80
3.4 Connection examples
Information:
The monitoring
device
and subsequent components must also be included when calculating the entire
enabling
safety
function.
A suitable monitoring
device
must be used to detect short and cross faults in the connecting cable.
3.4.1 Connection example for stop button
Connection example with monitoring
device
for
safety
circuits up to category 3 PL d per
EN
ISO
13849-1:2008.
Stop button
Control cabinet
+ 24 VDC
Auxiliary output
e.g. PLC error message output
Ye
llo
w
G
re
en
G
ra
y-
Pi
nk
W
hi
te
-G
re
en
R
ed
-B
lu
e
Br
ow
n-
G
re
en
Attachment cables
5CAMPH.0xxx-30
Enable
for the
hazardous
movement
Industrial connector
and
connection housing
Mobile Panel 40/50
(stop button wired with 2 circuits)
1) Contacts K1 and K2 must be positively driven!
Control cabinet cables
5CAMPC.0020-1x
Safety relay
Min. category 3 PL d
per EN ISO13849-1:2008.
Fe
ed
ba
ck
Pu
ls
e1
Pu
ls
e2
Sa
fe
In
pu
t 2
Sa
fe
In
pu
t 1
Figure 45: Connection example for stop button