![B&R 5MP040.0381-01 User Manual Download Page 63](http://html.mh-extra.com/html/bandr/5mp040-0381-01/5mp040-0381-01_user-manual_460436063.webp)
Technical data
Mobile Panel 40/50 User's manual V1.80
63
2.3.2.2.2 5CAMPC.0020-11
2.3.2.2.2.1 General information
A straight-through
control
cabinet cable is required for the wiring inside the
control
cabinet.
The pinout of the
Ethernet
connector (1:1) makes it possible to connect directly to a standard
Ethernet
hub
.
If the first
Ethernet
interface
on B&R
Ethernet
hub
AC808 (model number 0AC808.9) is used, it is important to
make sure that crossover (MDIX) is not enabled.
Ethernet RJ45 +
Shield (4 wires)
Enable switch (6 wires)
2 wires not used
Receptacle
for push-pull locking mechanism
RS232 (3 wires)
Not used
Stop / Emergency stop (6 wires)
2 wires not used
CAN + shield (5 wires)
Not used
Power supply
+ grounding
(3 wires)
Figure 39: 5CAMPC.0020-11 - Mobile Panel
control
cabinet cable
Information:
A
control
cabinet cable is used for the Mobile Panel 7100, Mobile Panel 40/50 and Mobile Panel 100/200
product series. Not all wires are used when wiring Mobile Panel 7100 and Mobile Panel 40/50 devices,
which limits their functionality compared to Mobile Panel 100/200 devices.
The surface is protected against water, oil (lubricating and hydraulic oils per
EN
60811 Part 2-1) and cooling
lubricant.
The
control
cabinet cable is fastened to the
control
cabinet door via the connection housing (
- Drilling template" on page 65
). The other end of the
control
cabinet cable has a pre-assembled RJ45
Ethernet
connector. The remaining lines have an open end with wire end sleeves to make it easier to wire to
safety
equipment
and other interfaces.
2.3.2.2.2.2 Order data
Model number
Short description
Figure
Control
cabinet cables
5CAMPC.0020-11
Mobile Panel
control
cabinet cable - Push-Pull circular connector
-
Ethernet
straight-through - 2 m
Optional accessories
Accessories
4MPCBX.0000-00
Mobile Panel connection box - For cables with push-pull circular
connectors
4MPCBX.0000-C01
SIT MP connection box PP
4MPCBX.0001-00
Mobile Panel small connection box - For cables with push-pull
circular connectors
Table 27: 5CAMPC.0020-11 - Order data
2.3.2.2.2.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
5CAMPC.0020-11
General information
Certifications
CE
Yes
GOST-R
Yes
Cable construction
Type
Straight-through
Table 28: 5CAMPC.0020-11 - Technical data