Dimensioning
SDL3 Converter User's manual V 2.00 Translation of the original documentation
21
4 Dimensioning
4.1 Spacing for air circulation
To ensure sufficient air circulation, a specified clearance must be provided above, below, to the side and behind
the device. For the minimum specified clearance, see the following diagrams. This is valid for all variants.
Information:
The following figure and table exclusively show the thermal view of the complete system. If additional
space is required for operating or servicing the device or using accessories (e.g. cable strain relief
clips), this must be taken into account during installation.
Legend
1)
Air outlet
2)
Air inlet
Spacing
Description
Dimension
Description
Dimension
S1
≥ 100
S2
≥ 50
S3
≥ 100
S4
≥ 50
Caution!
The specified spacing for air circulation is based on worst-case operation at the maximum specified
ambient temperature. The maximum specified ambient temperature is not permitted to be exceeded!