B&R Industries MAPPT-ENG User Manual Download Page 38

Installation  • Installation instructions

38

Power Panel T-Series User's Manual V 0.30 Preliminary

Chapter 3 • Installation

1 Installation instructions

The Power Panel must be mounted using the retaining clips included in delivery (with a torque of 0.6 Nm).
In order to guarantee sufficient air circulation, the specified amount of space above, below, to the side and behind

the Power Panel must be provided. The minimum specified spacing is indicated in the following diagrams. This

applies to all Power Panel variants.

At least

40 mm spacing

40 mm spacing

At least

Figure 21: Spacing for air circulation - Rear view

Summary of Contents for MAPPT-ENG

Page 1: ...f the date of publication however Bernecker Rainer Industrie Elektronik Ges m b H makes no warranty ex pressed or implied with regard to the products or documentation contained within this manual In a...

Page 2: ...Order number key 9 2 T Series 10 2 1 Selecting a Power Panel 10 2 2 General technical data 10 2 3 Overview 11 2 3 1 Overview 6PPT30 043x 11 2 3 2 Overview 6PPT30 057x 11 2 3 3 Overview 6PPT30 070x 11...

Page 3: ...nual V 0 30 Preliminary 3 2 1 Order data 44 2 2 Technical data 44 3 Data storage media 44 4 Cable accessories 44 Chapter 6 Maintenance 45 1 Cleaning 45 2 Screen burn in on LCD TFT monitors 45 Chapter...

Page 4: ...sportation systems medical life support systems or weapons systems When using programmable logic controllers or operating monitoring devices as control systems together with a Soft PLC e g B R Automat...

Page 5: ...nitors and TV sets Measurement devices and equipment must be grounded Measurement probes on potential free measurement devices must be discharged on sufficiently grounded surfaces before taking measur...

Page 6: ...malfunctions When combined with high temperature and humidity aggressive gases e g with sulfur nitrogen and chlorine components can induce chemical reactions that can damage electronic components ver...

Page 7: ...sy to mount space savers And because they have no hard disks fans or batteries they are also maintenance free The panel front provides IP65 protection which makes these devices extremely well suited f...

Page 8: ...for quick navigation or easy access to the home screen or help system The option to choose between portrait and landscape format adds even more flexibility to the machine layout It is easy to switch...

Page 9: ...x 800 portrait WSVGA 600 x 1024 portrait Display touch screen technology and memory Standard memory TFT color analog resistive touch screen Interfaces on option board No option board Standard panel ov...

Page 10: ...n aluminium white or anthracite gray Landscape Portrait 6PPT30 0573 20W 6PPT30 0702 20W 6PPT30 101G 20W 6PPT30 057L 20W 6PPT30 070M 20W 6PPT30 101N 20W 6PPT30 0573 20B 6PPT30 0702 20B 6PPT30 101G 20B...

Page 11: ...e Anthracite Aluminum white Anthracite Page 13 Table 4 Overview 6PPT30 043x 2 3 2 Overview 6PPT30 057x Model number 6PPT30 0573 20W 6PPT30 0573 20B 6PPT30 057L 20W 6PPT30 057L 20B Figure Display TFT c...

Page 12: ...nthracite Page 19 Table 6 Overview 6PPT30 070x 2 3 4 Overview 6PPT30 101x Model number 6PPT30 101G 20W 6PPT30 101G 20B 6PPT30 101N 20W 6PPT30 101N 20B Figure Display TFT color Resolution WSVGA Display...

Page 13: ...racite gray pinstripe 6PPT30 043K 20W Power Panel T30 4 3 analog resistive touch screen 2 Ether net interfaces internal switch 2 USB 2 0 interfaces embedded client software VNC client mode Embedded we...

Page 14: ...100 m between 2 stations segment length Max transfer rate 10 100 Mbit s Transmission Physical interfaces 10BASE T 100BASE TX Half duplex Yes Full duplex Yes Autonegotiation Yes Auto MDI MDIX Yes IF2 i...

Page 15: ...al conditions Temperature Operation Horizontal installation 20 to 60 C Vertical installation 20 to 60 C Storage 20 to 60 C Transport 20 to 60 C Relative humidity Operation See humidity diagram Storage...

Page 16: ...e 6PPT30 057L 20W Power Panel T30 5 7 analog resistive touch screen 2 Ether net interfaces internal switch 2 USB 2 0 interfaces embedded client software VNC client mode Embedded web browser on board p...

Page 17: ...thernet Design 1x RJ45 shielded Cable length Max 100 m between 2 stations segment length Max transfer rate 10 100 Mbit s Transmission Physical interfaces 10BASE T 100BASE TX Half duplex Yes Full duple...

Page 18: ...Temperature Operation Horizontal installation 20 to 60 C Vertical installation 20 to 60 C Storage 20 to 60 C Transport 20 to 60 C Relative humidity Operation See humidity diagram Storage See humidity...

Page 19: ...y pinstripe 6PPT30 070M 20W Power Panel T30 7 analog resistive touch screen 2 Ether net interfaces internal switch 2 USB 2 0 interfaces embedded client software VNC client mode Embedded web browser on...

Page 20: ...ngth Max 100 m between 2 stations segment length Max transfer rate 10 100 Mbit s Transmission Physical interfaces 10BASE T 100BASE TX Half duplex Yes Full duplex Yes Autonegotiation Yes Auto MDI MDIX...

Page 21: ...N 60529 protection Back IP20 Front IP65 Environmental conditions Temperature Operation Horizontal installation 20 to 60 C Vertical installation 20 to 60 C Storage 20 to 60 C Transport 20 to 60 C Relat...

Page 22: ...e 6PPT30 101N 20W Power Panel T30 10 1 analog resistive touch screen 2 Ether net interfaces internal switch 2 USB 2 0 interfaces embedded client software VNC client mode Embedded web browser on board...

Page 23: ...rnet Design 1x RJ45 shielded Cable length Max 100 m between 2 stations segment length Max transfer rate 10 100 Mbit s Transmission Physical interfaces 10BASE T 100BASE TX Half duplex Yes Full duplex Y...

Page 24: ...otection Back IP20 Front IP65 Environmental conditions Temperature Operation Horizontal installation 20 to 60 C Vertical installation 20 to 60 C Storage 20 to 60 C Transport 20 to 60 C Relative humidi...

Page 25: ...reliminary 25 2 4 5 Ethernet LEDs LNK orange ACT green Figure 5 Ethernet and POWERLINK LEDs LED Color Status Description On No Ethernet activity on the bus ACT Orange Blinking Ethernet activity on the...

Page 26: ...iagram 6PPT30 043x 20x Temperature C Relative humidity RH non condensing Operation Storage Transport Figure 6 6PPT30 043x 20x Temperature Humidity diagram 6PPT30 057x 20x Temperature C Relative humidi...

Page 27: ...PPT30 070x 20x Temperature C Relative humidity RH non condensing Storage Transport Operation Figure 8 6PPT30 070x 20x Temperature Humidity diagram 6PPT30 101x 20x Temperature C Relative humidity RH no...

Page 28: ...ports that are accessible externally for the user IF3 IF4 Figure 10 USB port USB port Transfer rate1 Low speed 1 5 Mbit s full speed 12 Mbit s high speed 480 Mbit s Power supply Max 0 5 A IF3 or 0 1 A...

Page 29: ...being connected incorrectly and damaging the device Overload protection must be provided by an external fuse TBD A fast acting Pinout Terminal Assignment 1 24 VDC 2 GND Required accessories 0TB6102 20...

Page 30: ...30 Preliminary 2 4 8 Dimensions 2 4 8 1 Dimensions 6PPT30 043x 20x Landscape 140 96 R2 84 8 82 6 33 3 5 128 8 12 5 5 7 M5 6 23 138 7 Figure 13 Dimensions 6PPT30 043x 20x 6PPT30 043F Max control cabin...

Page 31: ...Panel T Series User s Manual V 0 30 Preliminary 31 Portrait 6 23 84 8 82 6 5 96 140 R 2 33 3 5 74 128 8 M5 12 5 138 7 Figure 14 Dimensions 6PPT30 043x 20x 6PPT30 043K Max control cabinet thickness 6 m...

Page 32: ...liminary 2 4 8 2 Dimensions 6PPT30 057x 20x Landscape 172 140 R2 127 9 42 8 5 M5 112 9 159 8 27 8 13 8 12 5 5 1 0 70 139 26 27 0 145 72 1 02 Figure 15 Dimensions 6PPT30 057x 20x 6PPT30 0573 Max contro...

Page 33: ...User s Manual V 0 30 Preliminary 33 Portrait 140 172 R 2 127 9 13 8 5 42 8 M5 27 8 112 9 159 8 1 0 70 139 12 5 5 1 0 26 27 145 72 Figure 16 Dimensions 6PPT30 057x 20x 6PPT30 057L Max control cabinet...

Page 34: ...iminary 2 4 8 3 Dimensions 6PPT30 070x 20x Landscape 197 140 R2 112 9 184 8 27 8 5 42 8 127 9 13 8 12 5 5 5 1 0 70 138 9 26 27 0 1 170 73 M5 Figure 17 Dimensions 6PPT30 070x 20x 6PPT30 0702 Max contro...

Page 35: ...User s Manual V 0 30 Preliminary 35 Portrait 197 140 R 2 27 8 5 42 8 184 8 112 9 M5 127 9 13 8 70 0 138 92 1 1 0 26 27 170 73 12 5 5 Figure 18 Dimensions 6PPT30 070x 20x 6PPT30 070M Max control cabine...

Page 36: ...s 6PPT30 101x 20x Landscape 276 172 5 27 8 160 112 9 42 8 127 4 27 8 264 13 8 5 12 5 R 2 17 02 0 131 42 13 8 1 0 26 19 60 56 145 8 158 03 171 18 92 0 129 52 1 138 275 Figure 19 Dimensions 6PPT30 101x...

Page 37: ...30 Preliminary 37 Portrait 5 42 8 27 8 M5 160 112 9 264 127 4 13 8 172 276 R2 12 5 5 17 02 0 131 42 138 275 1 18 92 0 129 52 26 19 0 60 56 158 145 8 1 Figure 20 Dimensions 6PPT30 101x 20x 6PPT30 101N...

Page 38: ...lips included in delivery with a torque of 0 6 Nm In order to guarantee sufficient air circulation the specified amount of space above below to the side and behind the Power Panel must be provided The...

Page 39: ...structions Chapter 3 Installation Power Panel T Series User s Manual V 0 30 Preliminary 39 Air outlet At least 60 mm spacing At least 60 mm spacing At least 45 mm spacing Air inlet Figure 22 Spacing f...

Page 40: ...orientations Caution The maximum permitted ambient temperature can be found in the technical data for the respective Power Panel 3 Grounding Grounding tongues on the circuit board ensure effective pr...

Page 41: ...onfiguration Possible operating modes 5 Touch screen calibration B R touch screen devices are equipped with a touch controller that supports hardware calibration As a result devices are pre calibrated...

Page 42: ...strial environments EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances RoHS EN 60529 Degrees of protectio...

Page 43: ...ion cable RJ45 to RJ45 2 m X20CA0E61 00300 PLK connection cable RJ45 to RJ45 3 m X20CA0E61 00500 PLK connection cable RJ45 to RJ45 5 m X20CA0E61 00800 PLK connection cable RJ45 to RJ45 8 m X20CA0E61 0...

Page 44: ...0 01 Terminal block Number of pins 2 female Type of terminal clamp Screw clamps Cage clamps Cable type Copper wires only no aluminum wires Distance between contacts 3 81 mm Connection cross section AW...

Page 45: ...eaned regularly 2 Screen burn in on LCD TFT monitors Screen burn in afterimages display memory effect image retention or image sticking occurs on LCD TFT displays if a static image is displayed for a...

Page 46: ...te Butylcellosolve Ether Acetone Methyl ethyl ketone Dioxan Cyclohexanone Methylisobutylketone MIBK Isophorone Formic acid 50 Acetic acid 50 Phosphoric acid 30 Hydrochloric acid 36 Nitric acid 10 Tric...

Page 47: ...gure 12 Grounding 29 Figure 13 Dimensions 6PPT30 043x 20x 6PPT30 043F 30 Figure 14 Dimensions 6PPT30 043x 20x 6PPT30 043K 31 Figure 15 Dimensions 6PPT30 057x 20x 6PPT30 0573 32 Figure 16 Dimensions 6P...

Page 48: ...30 0573 20W 6PPT30 0573 20B 6PPT30 057L 20W 6PPT30 057L 20B Technical da ta 17 Table 13 6PPT30 0702 20W 6PPT30 0702 20B 6PPT30 070M 20W 6PPT30 070M 20B Order data 19 Table 14 6PPT30 0702 20W 6PPT30 07...

Page 49: ...102 2110 01 44 6PPT30 043F 20B 13 6PPT30 043F 20W 13 6PPT30 043K 20B 13 6PPT30 043K 20W 13 6PPT30 0573 20B 16 6PPT30 0573 20W 16 6PPT30 057L 20B 16 6PPT30 057L 20W 16 6PPT30 0702 20B 19 6PPT30 0702 20...