2.2.3 Spacing for air circulation
In order to ensure sufficient air circulation, the specified clearance values must be observed above, below, to the
side and behind the device. For the minimum specified clearance, see the following diagrams. This applies to all
variants.
Information:
The following figure and table illustrate the complete system from a thermal point of view. Additional
space needed to operate or service the device must be taken into account during installation.
S4
S3
S2
S1
Figure 3: Automation PC 3100 - Spacing for air circulation
S1: ≥100 mm
S2: ≥50 mm
S3: ≥100 mm
S4: ≥50 mm
Caution!
The specified air circulation clearance values are based on worst-case operation at the maximum spec-
ified ambient temperature. Exceeding the maximum specified ambient temperature is not permitted!
If the specified air circulation clearance values cannot be observed, then the maximum specified tem-
peratures of the temperature sensors (see
"Position of temperature sensors" on page 26"" on page
) must be monitored by the user and appropriate measures taken if they are exceeded.