Panel PC 2200 built-in devices User's manual V 1.05 Translation of the original documentation
6.3 Terminal block for IF options
6.3.1 0TB1210.3100
6.3.1.1 General information
2-row 10-pin terminal block TB1210 is used to connect to the interfaces of various interface options.
6.3.1.2 Order data
Model number
Short description
Figure
Terminal blocks
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block
- Protected against vibration by the screw flange
Table 271: 0TB1210.3100 - Order data
6.3.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
0TB1210.3100
General information
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
1)
DNV GL
Temperature:
B
(0 - 55°C)
Humidity:
B
(up to 100%)
Vibration:
A
(0.7 g)
EMC:
B
(bridge and open deck)
2)
Terminal block
Note
Nominal data per UL
Number of pins
10 (female)
Type of terminal block
Push-in spring connection
Cable type
Only copper wires (no aluminum wires!)
Spacing
3.5 mm
Connection cross section
AWG wire
26 to 16 AWG
Wire end sleeves with plastic covering
0.14 to 1 mm²
Solid wires
0.14 to 1.5 mm²
Fine strand wires
0.14 to 1.5 mm²
With wire end sleeves
0.14 to 1.5 mm²
Electrical characteristics
Nominal voltage
300 V
Nominal current
3)
10 A
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Table 272: 0TB1210.3100 - Technical data