10. Safety Beam Kit

WARNING! The Opener must be fitted with Safety Beams if:

•  the closing force at the bottom edge of the door exceeds 400N (40kg) and/or;

•  the opener has a smart device fitted to operate the door, when not in line-of-sight.

CAUTION! The Safety Beam must be installed and connected 

before the travel limits are set.

10.1 Inserting batteries into receiver and transmitter

a. Insert two (2) C-Type batteries into the Receiver (RX) and the Transmitter (TX) by removing the front cover. 

b. Put cover back on Transmitter and Receiver and secure with four (4) M6 x 25 screws (black).

4

1

5

2

3

5

Right side 

bracket

65mm

100mm

TX 

Sun or Shade

Receiver

RESET

LED

Apply pressure here Pull covers apart

10.2 Assemble the Mounting Bracket

a. Attach the PE 2000TS Bracket  

1

 to the Safety Beam Transmitter 

(TX) using four (4) M3 x 5 Taptite screws 

4

b. Connect the mounting bracket 

3

 to the adjustment bracket 

2

 

with two (2) of the M5 x 10 Pan Head Screws 

5

.

c. Repeat steps (a) and (b) to assemble the Safety Beam Receiver 

(RX).

d. Mount the receiver on the side of the doorway in shade and the 

transmitter on the other side in line with the receiver. The mounting 

surface should be rigid. Affix with a minimum of four (4) screws  

(not supplied).

10.3 Mounting the Bracket

The transmitter and receiver need to be placed in line of sight, with 

the beam 100mm above the ground level (as per AS/NZS 60335-

2-95:2020). This can be achieved by ensuring the bottom of the 

receiver and transmitter are 65mm above ground level. They should 

also be placed as close as possible to the door opening with the 

receiver (RX) in shade and the transmitter (TX) in sun or shade.

Assembling Flush Mounting Kit (for minimum sideroom applications)

a. Attached the transmitter (TX) and receiver (RX) to the two (2) 

PEB4-W1 Bracket 

1

with the four (4) M3 x 8 Taptite screws “P” 

4

b. Ensure to take note of the ATA recommendation in step (d) above 

and fix the TX and RX to the wall or rigid surface using the two (2) 

6.9 x 25 plastic wall plugs (if wall) and two (2) M6 x 25 self tapping 

screws.  

10.4 Aligning the Transmitter and Receiver

a. Power up the opener with the safety beams connected. 

b. The LED on the receiver and transmitter will light up and flicker. 

indicating communication is being established between each 

unit and the base station. This can take up to 60secs. Lights will: 

(i) Stay on solid = When communication is established but limits are not set.

(i) Go out = When communication is established and limits are set.

b. The opener beam alignment feature can be used to align beams via the beeper 

and main light as a guide;

(i) bright = aligned

(i) dull and Beeper sound = not aligned or blocked.

When the beams are aligned, continue with Section 12 Setting Limits.

tip

If the lights does not dim and the beeper does not sound when an object blocks 

the beam then the beam  is not being detected by the opener. - check the PE beam 

wiring, batteries and alignment.

Summary of Contents for Smart Pro SDO-9V3

Page 1: ...ion instructions Smart Pro Smart Secure These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161083_01 RELEASED 15 12 22...

Page 2: ...ny fixed controls permanently fix the label concerning the manual release adjacent to its actuating member after installation ensure that the mechanism is properly adjusted and that the drive reverses...

Page 3: ...ox 9kgs Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm gr...

Page 4: ...battery is swallowed or enters the body it can cause severe internal burns and can lead to DEATH in as little as 2 hours Always completely secure the battery compartment If the battery compartment do...

Page 5: ...rated angle which MUST be securely fastened to a structural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii does it have exposed beams The opener...

Page 6: ...o Extension Kit 3156mm Rail 1 Extension Kit 3946mm Rail 2 Extension Kits 4736mm Rail refers to 3160 rail 170mm 1 8 2 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protec...

Page 7: ...al supports otherwise opener failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profression...

Page 8: ...bt about the door s strength reinforcement may be added to the door s frame where necessary Door damage may occur if the bracket is installed on a panel with insufficient strength The opener s warrant...

Page 9: ...he beam 100mm above the ground level as per AS NZS 60335 2 95 2020 This can be achieved by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as...

Page 10: ...180mm 180mm Rated load 450N 400N 400N Maximum lifting under spring tension 200N 20kg 200N 20kg 200N 20kg Receiver type Multi frequency Multi frequency Multi frequency Receiver code storage capacity 6...

Page 11: ...e speed not suitable release button THEN HOLD Each press changes speed as per table MAIN LIGHT BEEPER SPEED MODE x 3 3 x FAST Default x 2 2 x MEDIUM x 1 1 x SLOW RELEASE When at desired speed S T E P...

Page 12: ...D lit Press repeatedly R E P R O F I L I N G T H E D O O R HOLD for 2 secs Door will open and close Re profiling is a simple way of re learning the travel characteristics of a previously setup Limit S...

Page 13: ...e tension Should the door become hard to operate or completely inoperative contact a door professional d Guide Tracks Clean the internal sections of the guide tracks every 3 6 months with a cloth damp...

Page 14: ...after hitting an obstruction or stalling ii Safety Beam triggered auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is t...

Page 15: ...S O R I E S Alignment Mode is entered Ensure Alignment For PE Beams HOLD for 2 secs till 3 beeps are heard OFF Then replace controls cover Re registering is required every time an accessory is remove...

Page 16: ...a pen HOLD for 2 sec the middle button through the coding hole S T E P T H R E E Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Take new remote RELEASE S T E P F I V E Press to test Opene...

Page 17: ...emove controls cover till remote LED lit Press repeatedly I N S T A L L I N G W A L L R E M O T E C O N T R O L S T E P T W O HOLD Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Release bo...

Page 18: ...connecting to wifi Remove controls cover Press repeatedly LED will turn PURPLE HOTSPOT ON S T E P T H R E E Open APP and click START W A R N I N G This device allows for operation of the door when not...

Page 19: ...D I S E N G A G E T H E O P E N E R 2 0 M A N U A L D O O R O P E R AT I O N C A U T I O N W h e n t h e o p e n e r i s m a n u a l l y d i s e n g a g e d t h e d o o r i s n o l o n g e r l o c k e...

Page 20: ...r stopped 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow Illuminates when battery is charged and flashes when bat...

Page 21: ...ter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter throug...

Page 22: ...E beam being blocked on closing hit an obstruction etc Also can occur if battery is activated x 4 or x 5 Position Fault x 6 Motor driving in wrong direction x 7 Memory fault x 8 Motor current sensor f...

Page 23: ...ening of door mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure...

Page 24: ...old waste facilitates the recovery of organic materials through alternative waste technologies such as composting Batteries and heavy metals are known contaminants in compost The community supports re...

Page 25: ...Y LED off Battery not used not fitted solid Battery charged flash 2 secs in use holding STOP for 10s will shutdown flashing Battery charging when connected to power rapid flashing Battery failed fault...

Page 26: ...E N T M O D E I N S T R U C T I O N S S T E P T W O S T E P F O U R If no beep is heard max or min setting is reached Press to move through options as per table below OR Observe the number of flashes...

Page 27: ...to save Then refit controls cover Press to exit Remove controls cover till gear LED flashing Press repeatedly When activated PET mode drives the door to a preset position from the close position there...

Page 28: ...CLOSE limit should be when rubber strip touches the ground to Close S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as thi...

Page 29: ...ia Pty Ltd 29 your representative is Smart Pro Smart Secure installation instructions G Setting up Tilt Door Prior to limit set up the opener can be set to J Type Tilt Profile This process allows the...

Reviews: