5 Function
Operation Condition
【
Waiting Mode
】
When DC voltage is over 100V but doesn’t reach to 120V, the inverter enters a "Waiting mode".
Under this mode, it will continue checking if PV array has enough power to feedback into grid.
【
Self Testing Mode
】
After initialization is finished in "Waiting mode", if the PV voltage is over 120V and the grid voltage
& frequency meet the standard, the inverter will work in the "Self-Testing mode".
【
On-grid Mode
】
Under this mode
, SF series
inverters convert PV array’s DC into AC and feedback into grid.
【
Fault Mode
】
If any fault/error occurs, inverter stops generating power until the fault/error is cleared. Some
fault/error will recover itself, and some may need to restart manually to resolve.
CAUTION!
The inverter output power decrease is usual
under
the condition of thermal
protection, but if it occurs frequently, you need to check the heat sink or consider
putting the inverter in the place where have better air flow, and if output power
decreases caused by electrical problem, please ask for professional supports.