background image

Introductions 

The DP-660 is a dual output, DIN-Rail mounted, 65 watts switching power supply. 
It has over voltage protection in main output and over load latch off mode 
protection on all output.   

1.0 Input Specifications 

1.1 

Input voltage

 

The range of input voltage is from 85VAC to 270VAC 

1.2 

Input Frequency

 

The range of input frequency is from 47Hz to 63Hz. 

1.3 

Input current

 

The maximum input current is 2A at 115VAC or 1A at 230VAC. 

1.4 

Inrush current

   

The inrush current will not exceed 60A at 115VAC input or 30A at 230VAC 
input, cold start, 25deg. C. 

2.0 Output Specifications 

2.1 Load range 

 
Output 

Min. load 

Rated load 

Peak load 

Voltage accuracy

+24V 

0A 

2.5A 

6A 

23.76V to 24.24V

+5V 

0a 

0.5A 

 

4.75V to 5.25V 

At Factory, all outputs in 60% rated load conditions, the +24V output is set 
to between 23.76V and 24.24V and 5V is checked to be within the specified 
voltage accuracy range. 
Peak load can test for 10 sec. Typical when other output at rated load, AC 
input at 115VAC. 

2.2 

Ripple and noise

   

  the peak-to-peak ripple and noise for each output is less then 1% of output 
voltage at rated load. Measuring is done by 15MHz bandwidth limited 
oscilloscope and terminated each output with a 0.47uF capacitor. 

2.3 

Line regulation

 

the line regulation for each output is less then +/- 1% while measuring at 

 

1

Summary of Contents for DP-660

Page 1: ...al Power Supply User s Manual Introductions 1 1 0 Input Specifications 1 2 0 Output Specifications 1 3 0 General Features 2 4 0 Environment specifications 2 5 0 International standards 3 6 0 Mechanical Specification 4 ...

Page 2: ... 25deg C 2 0 Output Specifications 2 1 Load range Output Min load Rated load Peak load Voltage accuracy 24V 0A 2 5A 6A 23 76V to 24 24V 5V 0a 0 5A 4 75V to 5 25V At Factory all outputs in 60 rated load conditions the 24V output is set to between 23 76V and 24 24V and 5V is checked to be within the specified voltage accuracy range Peak load can test for 10 sec Typical when other output at rated loa...

Page 3: ...put and rated load which is measured from the end of the last charging pulse to when the main output drops down to 95 output voltage 3 3 Protection For some reason the power supply fails to control itself the build in over voltage protection circuit will shut down the outputs to prevent damaging external circuits The trip point is around 26V to 31V The power supply will go into latch off mode agai...

Page 4: ...frame testing Board only Internal PCB model No SNP 9069 5 1 Safety standards Designed to meet the following standards UL 1950 D3 CSA 22 2 No 234 VDE EN 60 950 5 2 EMI standards Designed to meet the following conducted limits FCC docket 20780 curve B VFG 243 3 ...

Page 5: ...ion Dimensions 44mm W x 150mm H x 122mm D 6 1 G N D G N D 5 O u t p u t D C 2 4 V 2 5 A D C 5 V 0 5 A DP 660 I n d u s t r i a l P o w e r S u p p l y N L N C F G 8 5 2 6 4 V A C I n p u t 5 0 6 0 H z 1 1 5 V 2 A 2 3 0 V 1 A 4 ...

Page 6: ...1 AC inputs connector Pitch 5 08mm screw terminal block Wire range 12AWG 22AWG 2 5mm Pin Assignments No connection Frame Ground AC Input N L N C F G 6 2 2 DC output connector Pitch 5 08mm screw terminal block Wire range 12AWG 22AWG 2 5mm Pin Assignments 5V Loading 24V Loading 24V GND GND 5V 5 ...