background image

Installation and Operations Manual 

— Model 730 Series 

INTRODUCTION 

B&B ARMR

                                                                                                                  

A Division of B&B Roadway and Security Solutions        

                                                                                            

0730-9001 Revision C2 

 

 

 SYMBOL MEANING: 

 

 

The lightning flash with arrowhead symbol, within an 
equilateral triangle, is intended to alert the user to the 
presence of non-insulated "dangerous voltage" within the 
product's enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons. 

 

 

The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintenance (servicing) instruction in the 
literature accompanying the product. 

 
B&B ARMR does not assume responsibility for injury to persons or property during 
installation, operation, or maintenance.  As the user, you are responsible for correct and 
safe installation, operation, and maintenance of this equipment. Users must follow the 
specific instructions and safety precautions located in this manual. In addition they must: 
Follow the safety standards of the Occupational Safety and Health Administration 
(OSHA), as well as other applicable federal, state, and local safety regulations and 
industry standards and procedures. For installation outside the United States, users must 
also follow applicable international, regional, and local safety standards. 
Engage only trained and experienced staff to install, operate, and maintain the equipment. 
Ensure that all repairs are performed correctly, using properly trained technicians and the 
correct tools and equipment. 

 

This steel barrier is heavy and may drop suddenly if installed 
improperly.  EXTREME care should be given to ensure a safe 
installation barrier is completed. 

Additional system safety devices may be included with this barrier system: 

o

 

Vehicle loop detector(s) – Safety loop 

o

 

Traffic arms  

o

 

Traffic lights  

How to Contact Us 

If you have any questions or experience any problems with your vehicle barrier—or if we 
can help you with any other facility security issues—please contact us directly at:

  

Corporate/Tech Support:      

  

B&B ARMR   

 

 

5900 S. Lake Forest Drive, Suite 230  
McKinney, TX 75070  USA   

 

Telephone: 

(972) 385-7899 

Toll Free:        (800) 367-0387 
Fax:    

(972) 385-9887 

E-mail

[email protected]

 

[email protected]

 

Summary of Contents for 730 Series

Page 1: ...ity Solutions 0730 9001 Revision C2 MODEL 730 SERIES BEAM BARRIER OPERATIONS MAINTENANCE MANUAL B B ARMR Corporate Office Technical Support 5900 S Lake Forest Drive Suite 230 McKinney TX 75070 Phone 8...

Page 2: ...hout the world to control access and to protect people equipment and facilities We offer a broad range of vehicle barrier and related security services Turnkey installations Routine barrier preventati...

Page 3: ...andards of the Occupational Safety and Health Administration OSHA as well as other applicable federal state and local safety regulations and industry standards and procedures For installation outside...

Page 4: ...ty ii How to Contact Us iii 1 ORIENTATION 5 1 1 Overview 5 2 OPERATION 6 2 1 Introduction 6 2 2 First Time Operation 6 2 3 Control 7 2 4 Operating Time 7 3 MAINTENANCE 8 3 1 Introduction 8 3 2 Monthly...

Page 5: ...el 730 vehicle barrier 1 1 1 Gate Arm The steel gate arm is engineered to distribute the crash impact load over the drive and receiver stanchion Coupled with the specified concrete bases the stanchion...

Page 6: ...gate is fully open and it closes before the gate starts to close Red amber traffic lights The light remains red if the gate is in any position except fully open Infrared safety beams to detect pedestr...

Page 7: ...eceiver post and does not oscillate contact hard or make excessive noise 2 3 Control The 730 barrier is controlled by the flow of hydraulic fluid under pressure from the HPU to the cylinder All contro...

Page 8: ...We recommend you perform the following visual inspections monthly on the barrier system An equipment maintenance log is supplied in the appendix to assist in the logging Inspect the condition of the f...

Page 9: ...FF position Inspect the hydraulic system for signs of oil leaks CAUTION The hydraulic system when in operation is under extreme pressure Verify pressure on the barrier is completely relieved prior to...

Page 10: ...s mechanical or electrical 6 Check PLC input on pumping unit 7 Check that safeties are clear 8 Check PLC output on pumping unit 9 Check push button operation Barrier does not close when commanded on c...

Page 11: ...a for debris and proper lubrication dry graphite spray 3 Check hydraulic cylinder clevis pins for lubrication multi grade grease 4 Check bearing grease Hydraulic unit excessively hot 1 Check that the...

Page 12: ...ot limited to unauthorized repairs improper installation installation not performed by BBRSS authorized personnel incoming supply power is outside the tolerance for the product failure to perform manu...

Page 13: ...Location ____________________________ techsupport bb armr com Date Performed By Checklist Complete Anomalies Notes Jan Yes No Feb Yes No Mar Yes No Apr Yes No May Yes No Jun Yes No Jul Yes No Aug Yes...