8b-3-3 Signboard Assembly
- Must be performed by a technician -
(1) replacing the lED bar
z
z
To avoid electric shock, accidents or injuries to yourself or other people, or damage to the electronic
circuits, be sure to turn off the power switch before starting work.
z
z
pC boards are sensitive to static electricity. If a person handles a pC board while
charged with static electricity, the parts on the pC board may be damaged. before
handling a pC board, discharge the static electricity from your body; for example, by
touching the surface of grounded metal.
1
Turn off the power switch. (See “7-6-1 Turning the power Switch On” on page 31.)
2
remove the three torx bolts (M5 x 12), and remove the signboard panel.
Torx bolt (M5 x 12)
Signboard panel
3
remove the two phillips truss screws (M4 x 8), and remove the harness cover.
Phillips truss screw (M4 x 8)
Harness cover