25
Eliminator Vacuum Tank (Tandem) User Manual
Rite Rate Flow System Field Operation
Pre-Operation Checks
1 . Check the hydraulic connections .
2 . Before starting the tractor, check all electrical connections at the Raven SCS660 NVM Controller and at the hitch .
3 . Start the tractor and turn the Raven SCS660 power
ON
and leave the
MASTER
switch in the
OFF
position . The display
on the Raven should light up .
4 . Check to see if the Krohne Optiflux Flow Meter is receiving power .
5 . Confirm the Raven has the correct programming (if incorrect, see “Rite Rate Flow System Programming” on Page
44) .
6 . Check to see that the
SPEED CAL
has been set to 598 .
7 . Check the
BOOM CAL
to see if it is correctly programmed with the proper width (in inches) of your plow/injector
toolbar) .
8 . Check the application rates programmed into
RATE 1 CAL
and
RATE 2 CAL
. If you desire, you can zero out any totals
showing for
TOTAL VOLUME
,
TOTAL AREA
, etc .
9 . With the tank empty, engage the hydraulics to lower the injector and start the slurry pump . The injector down pressure
will be applied but the discharge valve will not open and the pump will not turn with the
MASTER
switch in the
OFF
position . Check the pressure gage at the block to ensure proper down pressure for the injector .
10 . Disengage the hydraulic down pressure and lift the injector up .
11 . Fill the slurry tank .
12 . On the way to the field, check the speed calibration by pressing the
SPEED
button . The speed displayed should be
reasonably accurate when compared to the tractor’s speed .
Field Application
1 . Upon arrival at the field, make sure the Raven SCS660 has the
POWER
turned
ON
. Set the Flow Control switch to
RATE 1
or
RATE 2
for your desired application rate . Leave the
MASTER
switch
OFF
.
2 . Engage the hydraulics to lower the injector and apply down pressure .
DANGER
Disconnect power to the Raven SCS660 NVM
Controller before jump starting, welding, or charging
the battery.
1
2
3
4
5
6
7
8
9
0
BOOM
CAL
SPEED
CAL
METER
CAL
VALVE
CAL
RATE 1
CAL
RATE 2
CAL
VOL
TANK
TIME
SELF
TEST
CE
TOTAL
AREA
TOTAL
VOLUME
FIELD
AREA
FIELD
VOLUME
DISTANCE
SPEED
VOL /
MIN
AREA /
MIN
DATA
MENU
ENTER
POWER
FLOW CONTROL
MASTER
ON
OFF
RATE 1
RATE 2
MANUAL
INC
DEC
ON
OFF
Master Power Switch
Preprogrammed or
Manual Flow Control
Manual Flow Control
Override for Custom
Spot Application
Controls Power to
the Raven 660 PWM
Boost Box .
Scrolls Up or Down
through the Data Menu
Data Display
Screen
Toggles to Variable
Sub-Menus within a
Menu
Enters the Inputted
Information into the
Console
Figure 27
OPERATION
Summary of Contents for ELIMINATOR VACUUM TANK Series
Page 2: ...Serial Number Date of Purchase Purchased From Dealer s Address Dealer s Telephone...
Page 4: ......
Page 8: ...4 Eliminator Vacuum Tank Tandem User Manual...
Page 9: ...Eliminator Vacuum Tank Tandem User Manual 5 Safety...
Page 15: ...Eliminator Vacuum Tank Tandem User Manual 11 Technical Data...
Page 19: ...Eliminator Vacuum Tank Tandem User Manual 15 Operation...
Page 31: ...Eliminator Vacuum Tank Tandem User Manual 27 Maintenance...
Page 45: ...Eliminator Vacuum Tank Tandem User Manual 41 Troubleshooting...
Page 52: ...48 Eliminator Vacuum Tank Tandem User Manual...
Page 53: ...Eliminator Vacuum Tank Tandem User Manual 49 Notes...
Page 54: ...50 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Page 55: ...51 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Page 56: ...52 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Page 57: ......