PRINCIPLE DIAGRAM DISK-
ELECTRODES SETTING
After having installed the nozzle, check the correct position of the
electrodes and disk according to the following levels. It’s adviseable
to check levels after every intervention on head.
N.B. To prevent damage to the support effect nozzle assembly/
disassembly tasks with the aid of a wrench and counter-
wrench.
N.B. Ignition can be improved under certain working conditions by
slightly adjusting the position of the electrodes.
00029341
11
0002934150
N° 8736
- Observe the measurements indicated in the diagram when fitting
the fan.
FAN ASSEMBLY DIAGRAM
SUNTEC PUMP MOD. AT 3 45A
WITH BUILT IN FILTER
1 Solenoid blocking valve for in line cutt-off
(usually closed) 1
st
flame
2 Solenoid valve for switch-over between low and high modes
(usually open) 2
nd
flame
3 Pressure outlet
(pressure take-off for air gate hydraulic jack)
4 Low pressure regulator (1
st
flame)
5 High pressure regulator (2
nd
flame)
6 Suction
7 Return internal by-pass plug
8 Pressure outlet
(pressure gauge port and air bleed valve 1/8”)
9 Vacuum gauge port 1/8”
10 Nozzle outlet
N.B. The pump is preset at a 10 bar pressure (1
st
flame) and
18 bar (2
nd
flame).
MOD.
A B C D
RINOX
190L2 5 0,5-1 5-5,5 3,5-4
12 / 16
0006080951_201401
ENGLISH
Summary of Contents for RINOX 190 L2
Page 2: ......
Page 68: ...BALTUR 2 16 0006080951_201401 PYCCK...
Page 69: ...3 2 RC B 3 16 0006080951_201401 PYCCK...
Page 73: ...N 0002934100 1 B C 2 E F 3 4 1 5 2 7 16 0006080951_201401 PYCCK...
Page 75: ...EK EK 5 tw 9 16 0006080951_201401 PYCCK...
Page 76: ...3 AL 10 2 TSA 3 4 5 6 7 3 8 9 10 AL 10 1 3 10 16 0006080951_201401 PYCCK...
Page 79: ...0002934140 12 1 A 2 6 B 3 4 C 13 16 0006080951_201401 PYCCK...
Page 83: ......