background image

MC-614

QUICK START GUIDE

Ignition

Connector 1

Connector 2

17

16

15

14

12

13

10

11

9

7

6

5

8

4

3

2

1

External Regulator

Plug

Positive Battery Sense

(Required for Internal Regulator Only)

Isolated Ground Terminal

MUST be connected to system ground

Positive Output

Terminal

HOUSE BATTERY

BANK

10A

1A

D+

The wire diagram above shows a typical set-up for a

6-Series alternator to a MC-614 regulator. Connector 1

is for use with the internal regulator which connects to a

Yanmar Engine harness. Connector 2 is used with the

MC-614 or ARS-5 (as shown).
Alternators other than the 6-Series have similar, but

slightly different connections. If programming for specific

battery type, 12.5 volts on the battery are necessary.

Please refer to the Alternator Installation Guide for

specific connections.

FLIP OVER FOR MORE INFORMATION

1. Ground Input

2. Power Input

3. Ignition Input

4. Field Output

5. Alt. Temp.(-)

6. Alt. Temp.(+)

7. Bat. #1 Temp.(-)

8. Bat. #1 Temp.(+)

9. Positive Voltage Sensor

10. Data TX

11. Data RX

12. Stator In

13. Tach. Out

14. Bat. #2 Temp. (-)

15. Bat. #2 Temp. (+)

16. Aux. #1 Lamp

17. Dash Lamp

MC-614

Installation &

Operation Manual

www.balmar.net / Customer Service: +1 (360) 435-6100 x 1 / Technical S1 (360) 435-6100 x 3

SUP-0239  REVA

+