Balluff Micropulse BTL7-S510B Series Manual Download Page 1

BTL7-S510(B)-...

Micropulse Configuration Tool – Manual

english

+

USB-Configurable

Summary of Contents for Micropulse BTL7-S510B Series

Page 1: ...BTL7 S510 B Micropulse Configuration Tool Manual english USB Configurable...

Page 2: ...www balluff com...

Page 3: ...xplanation of the warnings 4 2 First steps 5 2 1 Installation 5 2 2 Uninstallation 5 2 3 Software update 5 3 Windows and tabs 6 3 1 The Start window 6 3 2 The Main window 7 3 3 Magnet tab 9 3 4 Output...

Page 4: ...ers type BTL7 S510 B to be quickly and simply configured The results of the configuration are displayed online The most significant features are Online display of the current position of the magnet Gr...

Page 5: ...nfiguration Tool is started the drivers for the communication box are installed The message Connect communication box is displayed 1 Connect the USB communication box to the PC using the USB cable 2 C...

Page 6: ...t be made If no connection to the communication box or to the transducer can be established this message will appear on the start screen and the main window is not shown Check the USB connection unplu...

Page 7: ...ide the limits LED 2 right LED Green Synchronous operation1 Internal measurement is synchronous to SSI query Off Asynchronous operation1 Internal measurement is asynchronous to SSI query Flashing gree...

Page 8: ...the menu commands The menu commands are described in Section 4 Menus starting on page 12 3 2 6 Update transducer Changed values for a configuration are displayed in the Configuration Tool by means of...

Page 9: ...can only be selected if the nominal length is 90 mm The distance between two magnets must be 65 mm 3 Windows and tabs continued DANGER Uncontrolled system movement When starting up if the position me...

Page 10: ...et but the direction of motion cannot be read Differential position Distance between two magnets This can only be selected if two magnets are selected see Magnet tab on page 9 Differential velocity Re...

Page 11: ...Or Enter values and confirm by pressing Enter Select the appropriate error value 3 4 5 Blue bar The selected function see 3 4 1 is shown and the data format for the SSI interface see 3 4 2 is display...

Page 12: ...updated a prompt appears The exit process can be cancelled 4 2 Transducer menu 4 2 1 Read Ctrl R The configuration of the connected transducer is read Reading must be acknowledged The current configu...

Page 13: ...e Configuration Tool switches to online mode If another transducer of the same type is connected in offline mode a prompt with the following options appears when switching to online mode Read Read the...

Page 14: ...Germany Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 8...

Reviews: