166
Figure 2: Assigning the digital output
Note
You can delay the pulse if needed.
1.18.3.4
Creating different exposure times for consecutive images
If you want to create a sequence of exposure times, you have to trigger the camera "externally" via pulse width:
1. Use
Timer
and
Counter
to build a sequence of different pulse widths.
2. Use the
Counter
for the time between the exposures (with respect to the readout times).
3. Afterwards, use an
AND
gate followed by
OR
gate to combine different exposure times.
Note
Please be sure that the sensor can output the complete image during
Counter1
or
Counter2
. Otherwise,
only one integration time will be used.
Figure 1: wxPropView - Logic gate principle
MATRIX VISION GmbH
Summary of Contents for MATRIX VISION mvBlueNAOS
Page 1: ...mvBlueNAOS Technical Manual English Version 2 14...
Page 2: ......
Page 8: ......
Page 22: ...14 MATRIX VISION GmbH...
Page 183: ...1 18 Use Cases 175 Figure 2 Sample settings MATRIX VISION GmbH...
Page 286: ...278 Test setup front side MATRIX VISION GmbH...
Page 292: ...284 MATRIX VISION GmbH...