www.balluff.com
9
english
5.1
Starting up the system
DANGER
Uncontrolled system movement
When starting up, if the inductive positioning system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
►
Persons must keep away from the system’s
hazardous zones.
►
Startup must be performed only by trained technical
personnel.
►
Observe the safety instructions of the equipment or
system manufacturer.
1.
Check connections for tightness and correct polarity.
Replace damaged connections.
2.
Turn on the system.
3.
Check measured values and adjustable parameters
and readjust the inductive positioning system, if
necessary.
Check for the correct values at the null point
and end point, especially after replacing the
inductive positioning system or after repair by
the manufacturer.
5.2
Operating notes
– Regularly check function of the inductive positioning
system and all associated components.
– Take the inductive positioning system out of operation
whenever there is a malfunction.
– Secure the system against unauthorized use.
5
Startup
BIP LD2-T_ _ _-03-S75
Inductive Positioning System
Summary of Contents for LD2-T048-03-S75
Page 2: ...www balluff com ...
Page 3: ...Betriebsanleitung BIP LD2 T_ _ _ 03 S75 deutsch ...
Page 4: ...www balluff com ...
Page 23: ...User s Guide BIP LD2 T_ _ _ 03 S75 english ...
Page 24: ...www balluff com ...
Page 43: ...Notice d utilisation BIP LD2 T_ _ _ 03 S75 français ...
Page 44: ...www balluff com ...
Page 63: ...Manuale d uso BIP LD2 T_ _ _ 03 S75 italiano ...
Page 64: ...www balluff com ...
Page 83: ...Manual de instrucciones BIP LD2 T_ _ _ 03 S75 español ...
Page 84: ...www balluff com ...
Page 103: ...操作手册 BIP LD2 T_ _ _ 03 S75 中文 ...
Page 104: ...www balluff com ...
Page 123: ...取扱説明書 BIP LD2 T_ _ _ 03 S75 日本語 ...
Page 124: ...www balluff com ...
Page 143: ......