background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Only System  

500 mA, IP67 

User´s  Guide 

 

 

Summary of Contents for IP67

Page 1: ...Power Only System 500 mA IP67 User s Guide...

Page 2: ...3 3 Features Advantages 4 3 4 Display 4 4 Indication 5 4 1 Base indicators 5 4 2 Remote indicators 5 5 Installation and Connection 6 5 1 Mutual Interference 6 5 2 Installation in Metal 6 5 3 Angle Of...

Page 3: ...ry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Syntax Numbers Decimal n...

Page 4: ...otected against unauthorized use 2 5 Meaning of the Warning Notices The warning notices in this guide and the measures described for avoiding dangers must be observed The warning notices contain the f...

Page 5: ...and on the offset between base and remote and is therefore limited For this reason the total current consumption of the connected load must not exceed the maximum power output of the remote 3 3 Featu...

Page 6: ...rs Function Green static Supply voltage OK Green flashing Supply voltage too low 4 2 Remote indicators Indicators Function Green static Supply voltage OK Green flashing No connection between base and...

Page 7: ...o induction effects Metallic objects on the coil cap cause the objects to be heated Install the components so that no metallic objects can collect on the coil cap When installing in metal the specifie...

Page 8: ...EMC requirements the receiver cable must not be longer than 10 m If a longer cable is used nevertheless take all necessary measures to protect the receiver from voltage spikes Electrical connections...

Page 9: ...rewed down state Connection type M12 A coded Dimensions D x L in mm M30 X 100 Weight Approx 160 g Tightening torque 70 Nm 6 3 Operating Conditions Base Transmission distance 1 5 mm Operating temperatu...

Page 10: ...te Connection type M12 A coded Dimensions D x L in mm M30 X 106 Weight Approx 160 g Tightening torque 70 Nm 7 3 Operating Conditions Remote Transmission distance 1 5 mm Operating temperature Ta 5 C 55...

Page 11: ...15 0000 1A 064 PX0234 XXX For Base XXX cable length BCC M425 0000 1A 064 PX0234 XXX For Base XXX cable length BCC M413 0000 2A 064 PX0234 XXX For Remote XXX cable length BCC M423 0000 2A 064 PX0234 XX...

Page 12: ...Inductiv Coupler Base 1 Remote 2 P0 Power Only Technology PNP variant 24 V power class 500 mA Housing shape M30x1 5 Housing material M brass and length Male M12 axial Number of pins and coding 9 2 Or...

Page 13: ...Balluff Network Interface www balluff com 12 Notes...

Page 14: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 07158 173 0 Fax 07158 5010 balluff balluff de Nr 884150 726 E 03 127436 Edition K18 Replaces Edition H17 Subject...