www.balluff.com
65
english
5
Secondary Device Functions (continued)
5.11 Internal Temperature
5.11.1 Description
The sensor is equipped with internal temperature
monitoring. This records the device temperature as well as
the maximum and minimum values during production and
since the last time the sensor was restarted.
An upper and a lower threshold value can be defined for
the device temperature module. If the threshold is
exceeded or if device limit values are exceeded or
undercut, the senor triggers IO-Link events.
5.11.2 Process Data
Object ID
Name
Description
Direction
0x0050 (80)
Device Temperature
Current device temperature in °C.
Output
Tab. 5-49: Internal temperature – Process data
5.11.3 ISDU
Name
Index
Subindex
Access
Length
Data Type Data Storage
Default
Device Temperature
0x0052 (82)
0
R
10 byte
INT16[]
No
–
Device Temperature
1
R
2 bytes
INT16
No
–
Minimum Device
Temperature Since
Reset
2
R
2 bytes
INT16
No
–
Maximum Device
Temperature Since
Reset
3
R
2 bytes
INT16
No
–
Lifetime Minimum
Device Temperature
4
R
2 bytes
INT16
No
–
Lifetime Maximum
Device Temperature
5
R
2 bytes
INT16
No
–
Device Temperature
Alarm Configuration
0x0053 (83)
0
R/W
4 byte
INT16[]
Yes
–
Lower Alarm Level
Device Temperature
1
R/W
2 bytes
INT16
No
−40 °C
Upper Alarm Level
Device Temperature
2
R/W
2 bytes
INT16
No
100 °C
Tab. 5-50: Internal temperature – ISDU (overview)
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......