BTL5-H1_ _-M_ _ _ _-H/W-S92/SR92/KA_ _/K_ _
Micropulse Linear Transducer - Rod Style
EU Directive 2004/108/EC (EMC Directive) and EMC Law
Generic standards: EN 61000-6-4 (Emission), EN 61000-6-2 (Noise Immunity)
Emission tests: RF emission EN 55011 Group 1, Class A
UL authorization
File No.
E227256
1
english
BTL5...KA_ _
Ø 5 for Hookspanner Ø 65,
tightening torque max. 100 Nm
BTL5...S92
➀
➀
H: 40 -1mm
W: 2" -0.04"
➁
BTL5...K_ _
BTL5...SR92
Proper application
The BTL5 Micropulse transducer is
intended to be installed in a machine
or system. Together with a controller
(PLC) or a master it comprises a posi-
tion measuring system and may only
be used for this purpose.
Installation
Ensure that no strong
electrical or magnetic
fields are present in the
immediate vicinity of the trans-
ducer.
The contact surface of the trans-
ducer must be completely con-
tacted by the mounting surface. To
achieve secure mounting, use the
proper nut for the mounting thread.
When tightening the nut, do not ex-
ceed a tightening torque of 100 Nm.
For horizontal mounting of trans-
ducer with stroke lengths greater
than 500 mm, the pressure tube
should be supported or attached at
its end. When installing in a hydrau-
lic cylinder, do not allow the magnet
ring to rub against the pressure
tube. The bore diameter in the pis-
ton and cylinder rod should be at
least 13 mm.
Startup
Observe all relevant safety regula-
tions!
Check connections: Components
can be damaged by improper con-
nections and overvoltage. Verify all
connections before applying power!
Turning on the system: Note that the
system may execute uncontrolled
movements when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no hazards
could result from these situations.
Check functionality: The functional-
ity of the transducer system and all its
associated components should be
regularly checked and recorded. In
particular, steps must be taken to
ensure that should the transducer
system become defective no hazards
to persons or property can result.
Fault conditions: When there is evi-
dence that the transducer system is
not operating properly, it should be
taken out of service and guarded
against unauthorized use.
Wiring
System and control cabi-
net must be at the same
ground potential.
No. 857 728 E • Edition 0708; specifications subject to changes.
Cable length
Baudrate [kBd]
< 25 m
1000
< 50 m
800
< 100 m
500
< 250 m
250
< 500 m
125
< 1000 m
100
< 1250 m
50
< 2500 m
20/10
BKS Connector,
View of solder end
of connector body
BKS-S 92-00 or
BKS-S 93-00
➀
Please note that that 24 V
must be supplied and not 5 V for
the CAN driver.
➀
unusable area
➁
not included
User's Manual
A detailed user'manual and con-
figuration guide for this trans-
ducer can be obtained at
www.balluff.de
using the
link Position Sensors, Micropulse
Transducers, User’s Manuals .....
E-mail requests can be made to
BTL5-H1...
Pin
S92/SR92
KA_ _/K_ _
Control and Data signals
1
CAN_GND
WH white
4
CAN_H
GY gray
5
CAN_L
GN green
Supply voltage (external)
3
0 V (GND)
BU blue
2
+24 V
➀
BN brown
Nom. length
= stroke
Damping zone
Mounting
surface
Magnet
Blind hole
M4×4/
6 deep
Thread size
H: M18×1.5
W: 3/4"-16UNF
Connector BKS-S 93-00
rotates in 90° steps