14
english
6.1
Accuracy
The specifications are typical values for the BTL7-V50D...
at 24 V DC and room temperature, with a nominal length
of 500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
1 µm
Non-linearity with a constant
distance between the magnet and
profile:
Nominal length ≤ 5500 mm
Nominal length > 5500 mm
±30 µm
±0.02 % FS
Hysteresis
≤ ±10 µm
Repeat accuracy
≤ ±5 µm
(typ. ±2.5 µm)
Temperature coefficient
1)
≤ 18 ppm/K
Velocity resolution
0.1 mm/s
Min. detectable velocity
1 mm/s
Max. detectable velocity
10 m/s
6.2
Ambient conditions
2)
Operating temperature
−40°C…+85°C
Storage temperature
−40°C…+100°C
Humidity
< 90%, non-
condensing
Rod pressure rating (when installed
in hydraulic cylinders)
For Ø 8 mm
< 250 bar
For Ø 10.2 mm
< 600 bar
Shock rating
Continuous shock
per EN 60068-2-27
3)
150 g/6 ms
150 g/2 ms
Vibration
per EN 60068-2-6
3)
20 g, 10…2000 Hz
Degree of protection per IEC 60529
Connector C003 (when attached)
IP67
6.3
Supply voltage (external)
Voltage, stabilized
4)
10…30 V DC
Ripple
≤ 0.5 V
SS
Current draw
(at 24 V DC)
≤ 140 mA to 1524 mm
≤ 180 mA from 1525 mm
Inrush current
≤ 500 mA
Reverse polarity protection
Up to 36 V
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V AC
6.4
Output
Short-circuit resistance
Signal cable to GND
6.5
Dimensions, weights
Rod diameter
8 mm or 10.2 mm
Nominal length
For Ø 8 mm
25…1016 mm
For Ø 10.2 mm
25…7620 mm
Weight (depends on length)
Approx. 2 kg/m
Housing material
Aluminum
Flange material
Stainless steel
Rod material
Stainless steel
Rod wall thickness
For Ø 8 mm
0.9 mm
For Ø 10.2 mm
2 mm
Housing mounting via threads M18×1.5 or 3/4"-16UNF
Tightening torque
Max. 100 Nm
6.6
Maximum sampling rate f
max
At nominal length
0050…0250 mm
0251…0600 mm
0601…1300 mm
1301…2700 mm
2701…5500 mm
5501…7600 mm
> 7601 mm
1160 Hz
1010 Hz
805 Hz
490 Hz
245 Hz
180 Hz
170 Hz
1)
Nominal length = 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard, resonant
frequencies excluded
4)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
6
Technical data
BTL7-V50D-M _ _ _ _ -A/B/Y/Z(8)-C003
Transducer — Rod Style
Summary of Contents for BTL7-V50D-M P-C003 Series
Page 1: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Betriebsanleitung deutsch...
Page 2: ...www balluff com...
Page 21: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 User s Guide english...
Page 22: ...www balluff com...
Page 41: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Manual de instrucciones espa ol...
Page 42: ...www balluff com...
Page 61: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Notice d utilisation fran ais...
Page 62: ...www balluff com...
Page 81: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Manuale d uso Italiano...
Page 82: ...www balluff com...