www.balluff.com
19
english
9
Resetting all values (reset)
NOTICE!
Interference in function
Resetting the values while the system is running may
result in malfunctions.
►
Stop the system before performing the reset.
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
Displayed values (example)
At 0…10 V
At 4…20 mA
5.39 V
9.15 mA
Activate reset
►
Simultaneously activate
a
and
b
for at least 4 s.
> 4 s
a
b
10.50 V
3.60 mA
Reset
►
Simultaneously activate
a
and
b
for at least 4 s.
> 4 s
a
b
0.00 V
4.00 mA
After activation:
⇒
All values are reset.
9.89 V
19.13 mA
⇒
Current position value is displayed.
⇒
Reset is deactivated.
Abort reset
Resetting can be aborted without any changes
being saved after the
Activate reset
step.
►
Briefly activate
a
and
b
simultaneously (< 1 s).
< 1 s
a
b
⇒
Current position value is displayed.
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -H/W(8)-S32/S115/_ _ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7 Series
Page 1: ...Betriebsanleitung BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 deutsch ...
Page 2: ...www balluff com ...
Page 28: ...User s Guide BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 english ...
Page 29: ...www balluff com ...
Page 55: ...Manual de instrucciones BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 español ...
Page 56: ...www balluff com ...
Page 82: ...Notice d utilisation BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 français ...
Page 83: ...www balluff com ...
Page 109: ...Manuale d uso BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 italiano ...
Page 110: ...www balluff com ...